ISO 17993:2002 specifies a method using high performance liquid chromatography (HPLC) with fluorescence detection for the determination of 15 selected polycyclic aromatic hydrocarbons (PAH) [naphthalene, acenaphthene, phenanthrene, fluoranthene, benzo(a)anthracene, benzo(b)fluoranthene, benzo(a)pyrene, dibenzo(a,h)anthracene, fluorene, anthracene, pyrene, chrysene, benzo(k)fluoranthene, indeno(1,2,3-cd)pyrene, benzo(ghi)perylene] in drinking and ground water in mass concentrations greater than 0,005 microgram/litre (for each single compound) and surface waters in mass concentrations above 0,01 microgram/litre. This method is, with some modification, also suitable for the analysis of waste water. This method may be applicable to other PAH, provided the method is validated for each case.
Abstract
Overview
EN ISO 17993:2003 (ISO 17993:2002 adopted by CEN) defines a validated laboratory method for the determination of 15 polycyclic aromatic hydrocarbons (PAH) in water. The procedure uses liquid–liquid extraction (typically with hexane), concentration of the extract, optional silica clean-up for contaminated samples, and separation by HPLC with fluorescence detection (wavelength programming). It is intended for drinking water, ground water (individual compound limits ≥ 0.005 µg/L) and surface waters (≥ 0.01 µg/L). With modifications the method can be applied to wastewater and to other PAH after validation.
Key Topics
- Target analytes: 15 PAH - naphthalene, acenaphthene, phenanthrene, fluoranthene, benzo(a)anthracene, benzo(b)fluoranthene, benzo(a)pyrene, dibenzo(a,h)anthracene, fluorene, anthracene, pyrene, chrysene, benzo(k)fluoranthene, indeno(1,2,3-cd)pyrene, benzo(ghi)perylene. (Note: acenaphthylene is excluded because it is not fluorescent.)
- Detection limits: method specifies suitability for concentrations above 0.005 µg/L (drinking/ground water) and 0.01 µg/L (surface water).
- Analytical principle: liquid–liquid extraction → solvent evaporation → reconstitution → HPLC separation (gradient elution) → fluorescence detection with excitation/emission programming for selective PAH identification and quantification.
- Sample handling: use glass or stainless containers, avoid plastics and organic contaminants; follow ISO 5667 guidance for sampling and preservation to minimize adsorption and photodegradation.
- Interferences: fluorescent or quenching co-eluting compounds, solvent residues and incomplete chromatographic resolution (e.g., dibenzo[a,h]anthracene/indeno[1,2,3-cd]pyrene). Method gives measures for clean-up and wavelength selection (suppression of perylene) to mitigate interference.
- Safety: some PAH are carcinogenic; common solvents (hexane, acetonitrile, dichloromethane) are toxic - follow laboratory safety rules.
Applications
- Regulatory compliance: monitoring drinking water and surface waters against EU limits (e.g., benzo(a)pyrene 0.010 µg/L; sum of four PAH 0.100 µg/L as noted in Council Directive 98/83/EC).
- Environmental monitoring: routine surveillance of rivers, groundwater and drinking-water sources for PAH contamination.
- Industrial wastewater testing: adaptable with modifications and validation for more polluted matrices.
- Research & forensics: quantification of PAH sources, fate and transport studies.
Related Standards (if applicable)
- ISO 5667-2, ISO 5667-3 - sampling and sample handling guidance
- ISO 8466-1 - calibration and evaluation of analytical methods (statistical evaluation)
- EN ISO 17993:2003 references and harmonizes with these standards for complete water quality testing workflows.
Keywords: EN ISO 17993:2003, PAH analysis, HPLC with fluorescence detection, liquid–liquid extraction, water quality testing, benzo(a)pyrene, drinking water monitoring.
Технические детали
- Технический комитет
- CEN/TC 230 - Water analysis
- SKU
- EN ISO 17993:2003
Похожие стандарты
Стандарты, упомянутые в описании
ISO 17993:2002
ДействующийWater quality — Determination of 15 polycyclic aromatic hydrocarbons (PAH) in water by HPLC with fluorescence…
Overview ISO 17993:2002 specifies a validated laboratory method for the determination of 15 polycyclic aromatic hydrocarbons (PAH) in water using liquid–liquid extraction followed by high performance…
BS ISO 5667-21:2010
ДействующийWater quality. Sampling - Guidance on sampling of drinking water distributed by tankers or means other than d…
BS ISO 5667-21:2010 Water quality. Sampling. Guidance on sampling of drinking water distributed by tankers or means other than distribution pipes This part of BS ISO 5667 establishes principles to be…
ISO 5667-3:2024
ДействующийWater quality — Sampling — Part 3: Preservation and handling of water samples
Overview ISO 5667-3:2024 - Water quality - Sampling - Part 3: Preservation and handling of water samples is the sixth edition of the ISO guidance on how to preserve, handle, transport and store water…
BS ISO 8466-1:2021
ДействующийWater quality. Calibration and evaluation of analytical methods - Linear calibration function
1 Scope This document specifies various calibration strategies for physicochemical and chemical analytical methods and specifies the calculation of analytical results. It defines the general context…