EN ISO 22442-3:2007 PDF
Medical devices utilizing animal tissues and their derivatives - Part 3: Validation of the elimination and/or inactivation of viruses and transmissible spongiform encephalopathy (TSE) agents (ISO 22442-3:2007)
Medical devices utilizing animal tissues and their derivatives - Part 3: Validation of the elimination and/or inactivation of viruses and transmissible spongiform encephalopathy (TSE) agents (ISO 22442-3:2007)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 31
- Дата публикации:
- 15 декабря 2007 г.
- Издание:
- CEN EN 22442 edition 2 version 1
- ICS:
- 11.100.20
ISO 22442-3:2007 specifies requirements for the validation of the elimination and/or inactivation of viruses and TSE agents during the manufacture of medical devices (excluding in vitro diagnostic medical devices) utilizing animal tissue or products derived from animal tissue, which are non-viable or have been rendered non-viable. It applies where required by the risk management process as described in ISO 22442-1. It does not cover other transmissible and non-transmissible agents.
Abstract
Overview
EN ISO 22442-3:2007 (ISO 22442-3:2007) defines requirements for the validation of elimination and/or inactivation of viruses and transmissible spongiform encephalopathy (TSE) agents during manufacture of medical devices that utilize animal tissues or derivatives. It applies to non‑viable animal‑derived materials used in devices (excluding in vitro diagnostic devices) and is intended to be used where the risk management process (see ISO 22442‑1) identifies a need for validation. The standard supports demonstrated product safety by documenting scientifically sound validation studies, reporting, and routine process control.
Key Topics
- Scope and applicability - Focus on animal‑derived medical devices and processes that require viral/TSE control; excludes other transmissible or non‑transmissible agents and IVDs.
- Risk management linkage - Applies when the risk assessment (ISO 22442‑1) indicates potential viral/TSE transmission risk.
- Literature review - Systematic review of published data to identify known risks and prior evidence of inactivation or removal for specific agents and processes.
- Validation study design - Requirements for protocols, scaled‑down models, inoculation and challenge studies, controls, and acceptance criteria.
- Conduct and interpretation - Guidance on executing studies, calculating reduction factors, statistical evaluation of virus titres, and assessing the validity of results.
- Reporting and review - Requirements for a comprehensive final validation report and independent review.
- Routine monitoring - Ongoing control of critical process parameters and maintenance of validated conditions in production.
- Informative annexes - Practical guidance on viruses vs. TSE agents, scaling‑down, statistical methods, reduction factor calculations, and detection probabilities.
Applications
EN ISO 22442-3 is used to validate manufacturing steps that claim to remove or inactivate viral and TSE agents, for example:
- Processing steps for bovine/porcine heart valves, collagen coatings, bone substitutes, haemostatic products.
- Use of animal‑derived reagents or process aids (e.g., foetal calf serum, tallow derivatives) where residual risk must be controlled.
- Demonstrating efficacy of sterilization, chemical inactivation, filtration, or process washing steps in removing infectious agents.
Who should use this standard
- Medical device manufacturers using animal‑origin materials
- Validation scientists and process engineers
- Quality and regulatory teams preparing technical documentation
- Notified Bodies and auditors assessing conformity with EU Medical Device Directive requirements
- Laboratories planning viral inactivation/removal studies
Related standards
- ISO 22442‑1 - Application of risk management (precedes validation need)
- ISO 22442‑2 - Controls on sourcing, collection and handling of animal tissues
- ISO 13485 - Quality management system for medical device manufacture
- EU Medical Device Directive 93/42/EEC (as referenced for conformity)
Keywords: EN ISO 22442-3:2007, validation of inactivation, virus elimination, TSE agents, medical devices utilizing animal tissues, risk management, viral reduction factors, validation protocol.
Технические детали
- Технический комитет
- CEN/TC 206 - Biocompatibility of medical and dental materials and devices
- SKU
- EN ISO 22442-3:2007
Похожие стандарты
Стандарты, упомянутые в описании
ISO 22442-3:2007
ДействующийMedical devices utilizing animal tissues and their derivatives — Part 3: Validation of the elimination and/or…
Overview ISO 22442-3:2007 specifies requirements for the validation of methods used to eliminate and/or inactivate viruses and transmissible spongiform encephalopathy (TSE) agents during the manufact…
SIST EN ISO 22442-1:2021
ДействующийMedical devices utilizing animal tissues and their derivatives - Part 1: Application of risk management (ISO…
Overview EN ISO 22442-1:2020 - Medical devices utilizing animal tissues and their derivatives - Part 1: Application of risk management - specifies how to apply risk management principles to medical d…
SIST EN ISO 22442-3:2008
ДействующийMedical devices utilizing animal tissues and their derivatives - Part 3: Validation of the elimination and/or…
Overview EN ISO 22442-3:2007 (ISO 22442-3:2007) defines requirements for the validation of elimination and/or inactivation of viruses and transmissible spongiform encephalopathy (TSE) agents during m…
SIST EN ISO 22442-2:2021
ДействующийMedical devices utilizing animal tissues and their derivatives - Part 2: Controls on sourcing, collection and…
Overview EN ISO 22442-2:2020 - Medical devices utilizing animal tissues and their derivatives - Part 2: Controls on sourcing, collection and handling (ISO 22442-2:2020) is a CEN-adopted international…
SIST EN ISO 13485:2016/A11:2021
ДействующийMedical devices - Quality management systems - Requirements for regulatory purposes (ISO 13485:2016)
Overview EN ISO 13485:2016/A11:2021 is the European amendment (A11) to the international standard ISO 13485:2016 specifying quality management system (QMS) requirements for medical devices. Prepared…