EN ISO 23747:2015 PDF
Anaesthetic and respiratory equipment - Peak expiratory flow meters for the assessment of pulmonary function in spontaneously breathing humans (ISO 23747:2015)
Anaesthetic and respiratory equipment - Peak expiratory flow meters for the assessment of pulmonary function in spontaneously breathing humans (ISO 23747:2015)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 38
- Дата публикации:
- 19 августа 2015 г.
- Издание:
- CEN EN 23747 edition 2 version 1
- ICS:
- 11.040.10
ISO 23747:2015 specifies requirements for a peak expiratory flow meter (pefm) intended for the assessment of pulmonary function in spontaneously breathing humans. ISO 23747:2015 covers all medical devices that measure peak expiratory flowrate in spontaneously breathing humans either as part of an integrated lung function medical device or as a stand-alone medical device. Planning and design of products applying to this International Standard are to consider the environmental impact from the product during its life cycle. Environmental aspects are addressed in Annex E. NOTE Additional aspects of environmental impact are addressed in ISO 14971.
Abstract
Overview
EN ISO 23747:2015 (ISO 23747:2015) specifies requirements for peak expiratory flow meters (PEFMs) intended to assess pulmonary function in spontaneously breathing humans. Adopted by CEN, this international standard applies to PEFMs used as standalone devices or as part of integrated lung‑function systems. It updates and supersedes the 2009 edition and provides technical, safety and testing guidance for manufacturers, test laboratories and regulatory bodies.
Key topics and technical requirements
The standard addresses the following core technical subjects and requirements:
- Scope and definitions: Applicability to medical devices that measure peak expiratory flowrate in spontaneously breathing humans.
- General safety: Mechanical and electrical basic safety principles for respiratory and anaesthetic equipment.
- Performance requirements:
- Measurement range and error of measurement
- Linearity, resistance to flow, and frequency response
- Repeatability and measurement uncertainty
- Testing methods: Normative test procedures are given in Annexes B–D for error, frequency response, dismantling, ageing and drop tests.
- Durability & maintenance: Procedures for dismantling/reassembly, effects of mechanical ageing and dropping (hand‑held devices).
- Cleaning, sterilization and disinfection: Requirements for reusable devices and sterile‑delivered parts.
- Identification, marking and documentation: Labelling of scales/displays, device/packaging marking, and instructions for use.
- Biocompatibility and material compatibility: Expectations for materials in contact with patients.
- Environmental aspects: Lifecycle environmental impact considerations are addressed in Annex E; ISO 14971 is referenced for additional risk/environmental considerations.
- Regulatory alignment: Informative Annex ZA maps clauses to EU Medical Device Directive 93/42/EEC essential requirements.
Applications and who uses this standard
EN ISO 23747:2015 is intended for:
- Manufacturers and designers of PEFMs (stand‑alone or integrated) to ensure device safety, performance and regulatory conformity.
- Test laboratories and conformity assessment bodies performing performance and durability testing per the standard’s normative methods.
- Regulatory and procurement specialists assessing compliance with EU and international medical device requirements.
- Healthcare providers and clinical engineers who specify or validate peak flow measurement devices for pulmonary function assessment.
Practical applications include device design validation, type testing, regulatory submissions and quality assurance for peak expiratory flow measurement instruments.
Related standards
- ISO 14971 (medical device risk management) - referenced for broader environmental and risk considerations.
- EU Directives and national standards - Annex ZA relates EN ISO 23747 to Directive 93/42/EEC essential requirements.
Keywords: EN ISO 23747:2015, ISO 23747:2015, peak expiratory flow meter, PEFM, pulmonary function, peak expiratory flowrate, respiratory equipment, medical device standard.
Технические детали
- Технический комитет
- CEN/TC 215 - Respiratory and anaesthetic equipment
- SKU
- EN ISO 23747:2015
Похожие стандарты
Стандарты, упомянутые в описании
ISO 23747:2015
ДействующийAnaesthetic and respiratory equipment — Peak expiratory flow meters for the assessment of pulmonary function…
Overview ISO 23747:2015 - Anaesthetic and respiratory equipment: Peak expiratory flow meters (pefm) - specifies safety and performance requirements for devices that measure peak expiratory flow (PEF)…
BS/AAMI 34971:2023
ДействующийApplication of ISO 14971 to machine learning in artificial intelligence. Guide.
SIST EN ISO 23747:2015
ДействующийAnaesthetic and respiratory equipment - Peak expiratory flow meters for the assessment of pulmonary function…
Overview EN ISO 23747:2015 (ISO 23747:2015) specifies requirements for peak expiratory flow meters (PEFMs) intended to assess pulmonary function in spontaneously breathing humans. Adopted by CEN, thi…