Acoustics - Reference zero for the calibration of audiometric equipment - Part 5: Reference equivalent threshold sound pressure levels for pure tones in the frequency range 8 kHz to 16 kHz (ISO 389-5:2006)
Acoustics - Reference zero for the calibration of audiometric equipment - Part 5: Reference equivalent threshold sound pressure levels for pure tones in the frequency range 8 kHz to 16 kHz (ISO 389-5:2006)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 13
- Дата публикации:
- 15 ноября 2006 г.
- Издание:
- CEN EN 389 edition 2 version 1
- ICS:
- 13.140
ISO 389-5:2006 specifies reference equivalent threshold sound pressure levels (RETSPLs) of pure tones in the frequency range from 8 kHz to 16 kHz applicable to the calibration of air conduction audiometers for specific earphones.
Abstract
Overview
EN ISO 389-5:2006 (CEN endorsement) defines reference equivalent threshold sound pressure levels (RETSPLs) for pure tones in the extended high‑frequency range 8 kHz to 16 kHz. It provides standard RETSPLs and calibration specifications for air‑conduction audiometers when used with specific earphones and ear‑simulator/adapter combinations. The standard supports uniform, traceable audiometer calibration for extended high‑frequency audiometry.
Key topics and technical requirements
- Scope: RETSPL values of pure tones from 8 kHz to 16 kHz for calibration of air‑conduction audiometers.
- Specified earphones: Values are given for specific models:
- Etymotic Research ER-2 (with ER1-14A eartips) - RETSPLs (dB re 20 µPa): 8 kHz 19; 9 kHz 16; 10 kHz 20; 11.2 kHz 30.5; 12.5 kHz 37; 14 kHz 43.5; 16 kHz 53.
- Sennheiser HDA 200 (closed circumaural) - RETSPLs (dB re 20 µPa): 8 kHz 17.5; 9 kHz 19; 10 kHz 22; 11.2 kHz 23; 12.5 kHz 27.5; 14 kHz 35; 16 kHz 56.
- Dependence on measurement setup: RETSPLs depend on earphone model and the ear simulator + adapter used (e.g., IEC 60318‑1, IEC 60711, IEC 60318‑2, ISO 389‑2 adapters).
- Calibration notes and tolerances:
- Values are arithmetic means of laboratory medians and rounded to the nearest 0.5 dB.
- Sennheiser HDA 200 shows temperature dependence (notably at 12.5 kHz); recommended calibration temperature 21 °C to 25 °C.
- Headband force for HDA 200: 10.0 ± 1.0 N with specified positioning (earphone separation 145 mm, headband height giving 130 mm center distance).
- Eartip insertion for ER‑2: insert deeply so outer end is flush with bottom of the concha.
- Supplementary info: Annex A explains derivation from multiple laboratory investigations; Annex B lists RETSPLs for the legacy Koss HV/1A earphone (for information).
Applications and users
- Calibration laboratories performing traceable audiometer calibration in the extended high‑frequency range.
- Audiometer and earphone manufacturers implementing calibration procedures and specifications.
- Clinical audiology and occupational health services requiring validated extended‑high‑frequency hearing tests.
- Research laboratories studying high‑frequency hearing or validating test equipment.
Related standards (normative references)
- ISO 389‑1, ISO 389‑2 (other parts of ISO 389 series)
- IEC 60318‑1, IEC 60318‑2, IEC 60711 (ear simulators and couplers)
- Part of the ISO 389 family covering reference zero for audiometric equipment.
Keywords: EN ISO 389-5:2006, RETSPL, audiometer calibration, 8 kHz to 16 kHz, extended high-frequency audiometry, Etymotic ER-2, Sennheiser HDA 200, audiometric standards.
Технические детали
- Технический комитет
- CEN/TC 211 - Acuostics
- SKU
- EN ISO 389-5:2006
Похожие стандарты
Стандарты, упомянутые в описании
ISO 389-5:2006
ДействующийAcoustics — Reference zero for the calibration of audiometric equipment — Part 5: Reference equivalent thresh…
Overview ISO 389-5:2006 is an international standard developed by the International Organization for Standardization (ISO) that specifies reference equivalent threshold sound pressure levels (RETSPLs…
IEC 60318-1:2009
ДействующийElectroacoustics - Simulators of human head and ear - Part 1: Ear simulator for the measurement of supra-aura…
Overview IEC 60318-1:2009 is an international standard developed by the International Electrotechnical Commission (IEC) that specifies an ear simulator designed for the precise measurement of supra-a…
IEC 60318-2:1998
Electroacoustics - Simulators of human head and ear - Part 2: An interim acoustic coupler for the calibration…
SIST EN ISO 3892:2002
ДействующийConversion coatings on metallic materials - Determination of coating mass per unit area - Gravimetric methods…
Overview - EN ISO 3892:2001 (ISO 3892:2000) EN ISO 3892:2001 specifies gravimetric methods for determining the coating mass per unit area of conversion coatings on metallic materials. It covers phosp…
SIST EN ISO 389-1:2018
ДействующийAcoustics - Reference zero for the calibration of audiometric equipment - Part 1: Reference equivalent thresh…
Overview EN ISO 389-1:2018 (ISO 389-1:2017) - "Acoustics - Reference zero for the calibration of audiometric equipment - Part 1" defines the reference equivalent threshold sound pressure levels (RETS…