EN ISO 5167-5:2022 PDF
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 5: Cone meters (ISO 5167-5:2022)
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 5: Cone meters (ISO 5167-5:2022)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 23
- Дата публикации:
- 2 ноября 2022 г.
- Издание:
- CEN EN 5167 edition 2 version 1
- ICS:
- 17.120.10
This document specifies the geometry and method of use (installation and operating conditions) of cone meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit. As the uncertainty of an uncalibrated cone meter might be too high for a particular application, it might be deemed essential to calibrate the flow meter in accordance with Clause 7. This document also provides background information for calculating the flow rate and is applicable in conjunction with the requirements given in ISO 5167‑1. This document is applicable only to cone meters in which the flow remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. Uncalibrated cone meters can only be used within specified limits of pipe size, roughness, β, and Reynolds number, Re. This document is not applicable to the measurement of pulsating flow. It does not cover the use of uncalibrated cone meters in pipes sized less than 50 mm or more than 500 mm, or where the pipe Reynolds numbers are below 8 × 104 or greater than 1,2 × 107. A cone meter is a primary device which consists of a cone-shaped restriction held concentrically in the centre of the pipe with the nose of the cone upstream. The design of cone meter defined in this document has one or more upstream pressure tappings in the wall, and a downstream pressure tapping positioned in the back face of the cone with the connection to a differential pressure transmitter being a hole through the cone to the support bar, and then up through the support bar. Alternative designs of cone meters are available; however, at the time of writing, there is insufficient data to fully characterize these devices, and therefore, these meters shall be calibrated in accordance with Clause 7.
Abstract
Overview
EN ISO 5167-5:2022 (ISO 5167-5:2022) defines the geometry and method of use for cone meters - a class of differential-pressure primary devices - when inserted in circular cross‑section conduits running full to determine fluid flow rate. The standard covers device shape, pressure tapping arrangements, installation and operating conditions, calculation background (discharge coefficient and expansibility factor), and guidance on uncertainty. It applies to subsonic, single‑phase flows and is intended to be used together with ISO 5167‑1 and other parts of the ISO 5167 series.
Key topics and requirements
- Cone meter geometry and pressure tappings
- Cone held concentrically with the cone nose upstream.
- One or more upstream wall tappings; downstream tapping in the cone back face with a thru‑cone connection to the support bar.
- Alternative cone designs require laboratory calibration (Clause 7) due to limited characterization data.
- Limits of use for uncalibrated meters
- Uncalibrated cone meters may only be used within specified limits of pipe size (50–500 mm), pipe roughness, diameter ratio β, and Reynolds number (Re between 8×10^4 and 1.2×10^7). Not applicable to pulsating flow.
- Flow computation parameters
- Discharge coefficient (C): specified method for determining C and its uncertainty; can be improved via calibration.
- Expansibility (expansion) factor (ε): tables and uncertainty guidance provided for compressible fluids.
- Installation and operating conditions
- Minimum upstream/downstream straight lengths for common upstream disturbances (bends, valves, expanders).
- Pipe circularity/cylindricity, surface roughness, and thermowell positioning requirements to ensure measurement accuracy.
- Calibration and uncertainty
- Clause 7 outlines flow calibration procedures, test‑facility requirements, test program design, result reporting, and uncertainty analysis following ISO/IEC Guide 98‑3 principles.
Applications and users
Who uses EN ISO 5167-5:
- Flow measurement and metrology engineers
- Calibration laboratories and test facilities
- Manufacturers of differential‑pressure flow meters and cone meters
- Process engineers in water, wastewater, chemical, oil & gas and utility pipelines
- Companies implementing flow custody transfer or process control where primary device standards are required
Practical value:
- Provides repeatable, standardized methods for differential pressure flow measurement using cone meters
- Enables consistent estimation of flow rate and measurement uncertainty
- Supports selection, installation, and calibration strategies to meet regulatory, commercial, and process‑control requirements
Related standards
- ISO 5167‑1 (general principles and computation) - use in conjunction with Part 5
- Other parts of the ISO 5167 series (orifice plates, nozzles, Venturi tubes, wedge meters)
- ISO 2186 (secondary devices) and ISO/IEC Guide 98‑3 (uncertainty evaluation) for related metrology guidance
Keywords: EN ISO 5167-5:2022, ISO 5167-5, cone meter, differential pressure, flow measurement, discharge coefficient, expansibility factor, flow calibration, Reynolds number, pressure tappings.
Технические детали
- Технический комитет
- CEN/SS F05 - Measuring insreuments
- SKU
- EN ISO 5167-5:2022
Похожие стандарты
Стандарты, упомянутые в описании
ISO 5167-5:2022
ДействующийMeasurement of fluid flow by means of pressure differential devices inserted in circular cross-section condui…
Overview ISO 5167-5:2022 - Measurement of fluid flow by means of pressure differential devices inserted in circular cross‑section conduits running full - Part 5: Cone meters. This part of the ISO 516…
SIST EN ISO 5167-1:2022
ДействующийMeasurement of fluid flow by means of pressure differential devices inserted in circular cross-section condui…
Overview EN ISO 5167-1:2022 (ISO 5167-1:2022) establishes the general principles and requirements for measuring fluid flow in circular cross-section conduits running full using differential pressure…
SIST EN ISO 5167-5:2023
ДействующийMeasurement of fluid flow by means of pressure differential devices inserted in circular cross-section condui…
Overview EN ISO 5167-5:2022 (ISO 5167-5:2022) defines the geometry and method of use for cone meters - a class of differential-pressure primary devices - when inserted in circular cross‑section condu…