EN ISO 6926:2016 PDF
Acoustics - Requirements for the performance and calibration of reference sound sources used for the determination of sound power levels (ISO 6926:2016)
Acoustics - Requirements for the performance and calibration of reference sound sources used for the determination of sound power levels (ISO 6926:2016)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 29
- Дата публикации:
- 10 февраля 2016 г.
- Издание:
- CEN EN 6926 edition 2 version 1
- ICS:
- 17.140.01
ISO 6926:2016 specifies the acoustical performance requirements for reference sound sources: - temporal steadiness (stability) of the sound power output; - spectral characteristics; - directivity. Temporal steadiness is defined in terms of the standard deviation of repeatability (see 5.2). The spectral characteristics can be verified in either a hemi-anechoic room or a reverberation test room from measurements of the frequency band sound power levels in accordance with this International Standard (see 5.4). The performance requirements on directivity index can only be verified in a hemi-anechoic room (see 5.5.) ISO 6926:2016 also specifies procedures for providing level calibration data and uncertainty on a sound source intended for use as a reference sound source in terms of its sound power level under reference meteorological conditions as defined in Clause 4 in octave and in one-third-octave bands, and with frequency weighting A. ISO 6926:2016 is titled as a calibration standard even though the method is conducted in a testing laboratory and the level calibration results are not directly traceable to national standards of measure in a strict metrological sense. Testing laboratories performing this method are not expected to meet all requirements normally associated with a calibration laboratory. NOTE ISO/IEC 17025[15] specifies different requirements for the competence of testing laboratories and calibration laboratories respectively. Laboratories testing reference sound sources in accordance with this International Standard would typically comply with the requirements for testing laboratories but not necessarily with those for calibration laboratories. ISO 6926:2016 specifies methods to calibrate reference sound sources not only in a free field over a reflecting plane but also in reverberation test rooms at different distances from the boundary surfaces. For the position of the reference sound source on one reflecting plane, the two different test environments mentioned above are considered equivalent for frequency bands above or equal to 200 Hz. At 160 Hz and below, some systematic differences can occur (see 11.2). For frequencies below 100 Hz, an alternative calibration method using sound intensity is given. The sound source can either be placed directly on the floor or mounted on a stand to be used at a certain elevation above the floor. According to this International Standard, stand-mounted sources are calibrated in reverberation test rooms. Floor-mounted sources are either calibrated in hemi-anechoic or in reverberation test rooms. For floor-mounted sources in hemi-anechoic rooms, this International Standard is valid only for sources whose maximum vertical dimension is less than 0,5 m and whose maximum horizontal dimension is less than 0,8 m. According to this International Standard, only floor-mounted reference sound sources can be used when carrying out measurements on a measurement surface. For reference sound sources to be used or calibrated under reverberant conditions, no such restrictions on maximum dimensions apply.
Abstract
Overview - EN ISO 6926:2016 (Acoustics, Reference Sound Sources)
EN ISO 6926:2016 specifies performance and calibration requirements for reference sound sources used to determine sound power levels. Published by CEN and identical to ISO 6926:2016, it defines how to verify the stability, spectral output and directivity of reference sources and how to provide calibrated level data with associated uncertainty (octave and 1/3-octave bands, A‑weighting) under reference meteorological conditions.
Key topics and technical requirements
-
Temporal steadiness (stability)
- Stability is expressed as the standard deviation of repeatability (see clause 5.2). Laboratories must measure and report temporal steadiness over repeated runs.
-
Spectral characteristics
- Verification of frequency‑band sound power levels can be performed in a hemi‑anechoic room or a reverberation test room (see clause 5.4).
-
Directivity
- Directivity index performance requirements can only be verified in a hemi‑anechoic room (see clause 5.5).
-
Calibration environments and frequency considerations
- For a source on one reflecting plane, hemi‑anechoic and reverberation room results are considered equivalent for frequencies ≥ 200 Hz. Systematic differences may occur at 160 Hz and below; alternative sound‑intensity calibration is specified for frequencies
Технические детали
- Технический комитет
- CEN/TC 211 - Acuostics
- SKU
- EN ISO 6926:2016
Похожие стандарты
Упомянутые в описании и другие стандарты EN
ISO 6926:2016
ДействующийAcoustics — Requirements for the performance and calibration of reference sound sources used for the determin…
Overview ISO 6926:2016 - Acoustics - Requirements for the performance and calibration of reference sound sources used for the determination of sound power levels - defines performance criteria and ca…
EN ISO 6599-1:2026
ДействующийPackaging - Conditioning for testing - Part 1: Paper sacks (ISO 6599-1:2026)
Overview EN ISO 6599-1:2026 - Packaging - Conditioning for testing - Part 1: Paper sacks is a key international standard developed by CEN and ISO. This document defines the conditioning atmospheres a…
EN ISO 4885:2026
ДействующийFerrous materials - Heat treatments - Vocabulary (ISO 4885:2026)
Overview EN ISO 4885:2026 - Ferrous Materials – Heat Treatments – Vocabulary is an international standard developed by CEN, aligning with ISO 4885:2026. This document provides comprehensive definitio…
EN ISO/IEC 29151:2026
ДействующийInformation security, cybersecurity and privacy protection - Controls, requirements, and guidance for persona…
Overview EN ISO/IEC 29151:2026 specifies controls, requirements, and guidance to ensure the proper protection of personally identifiable information (PII) within the fields of information security, c…
EN ISO 9693:2026
ДействующийDentistry - Compatibility testing for metal-ceramic and ceramic-ceramic systems (ISO 9693:2026)
Overview EN ISO 9693:2026 - Dentistry: Compatibility Testing for Metal-Ceramic and Ceramic-Ceramic Systems establishes internationally recognized requirements and test methods for evaluating the ther…
EN ISO 26082-1:2026
ДействующийLeather - Physical and mechanical test methods for the determination of soiling - Part 1: Rubbing (Martindale…
Overview EN ISO 26082-1:2026 is a European standard titled "Leather - Physical and mechanical test methods for the determination of soiling - Part 1: Rubbing (Martindale) method" adopted by CEN. This…
EN ISO/IEEE 11073-10101:2020/A1:2026
ДействующийHealth informatics - Device interoperability - Part 10101: Point-of-care medical device communication - Nomen…
Overview EN ISO/IEEE 11073-10101:2020/A1:2026 is an amendment to the internationally recognized standard for health informatics and device interoperability, focusing specifically on the nomenclature…
EN ISO 11609:2026
ДействующийDentistry - Dentifrices - Requirements, test methods and marking (ISO 11609:2026)
Overview EN ISO 11609:2026 – Dentistry – Dentifrices – Requirements, Test Methods and Marking (ISO 11609:2026) defines the international requirements for the physical and chemical properties, test me…