Non-invasive sphygmomanometers - Part 1: Requirements and test methods for non-automated measurement type (ISO 81060-1:2007)
Non-invasive sphygmomanometers - Part 1: Requirements and test methods for non-automated measurement type (ISO 81060-1:2007)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 50
- Дата публикации:
- 23 мая 2012 г.
- Издание:
- CEN EN 81060 edition 2 version 1
- ICS:
- 11.040.10
ISO 81060-1:2007 specifies requirements for non-automated sphygmomanometers and their accessories, which, by means of inflatable cuffs, are used for the non-invasive blood pressure measurement by operator observation. ISO 81060-1:2007 specifies requirements for the safety and essential performance, including effectiveness and labelling, for non-automated sphygmomanometers and their accessories, including test methods to determine the accuracy of non-invasive blood pressure measurement. ISO 81060-1:2007 covers non-invasive blood pressure measurement devices with a pressure-sensing element and display used in conjunction with means of detecting blood flow.
Abstract
Overview
EN ISO 81060-1:2012 (adoption of ISO 81060-1:2007) sets requirements and test methods for non‑automated non‑invasive sphygmomanometers - the manual blood pressure instruments that use inflatable cuffs and operator observation (mercury, aneroid or pressure‑sensing displays used with blood‑flow detection). The standard focuses on safety, essential performance, accuracy testing, and labelling for devices and accessories used for non‑invasive blood pressure measurement.
Key Topics
- Scope and device types: Applies to non‑automated sphygmomanometers and accessories (inflatable cuffs, tubing, connectors) and to devices with pressure‑sensing elements and displays used with blood‑flow detection.
- Safety and mechanical/electrical requirements: General mechanical strength, electrical safety (where applicable) and ergonomic/usability considerations.
- Accuracy and test methods: Type tests and representative sample testing procedures to determine measurement accuracy and dynamic response under normal use.
- Pneumatic system and pressure indicating means: Requirements for cuff interface, tubing, valves and pressure indication (manometer characteristics, readability).
- Special requirements for mercury and aneroid devices: Design and handling controls to reduce mercury spillage risks and specific scale/assembly requirements for aneroid manometers.
- Marking, labelling and documentation: Legibility, durability, units of measurement, cuff marking and packaging information to support safe and effective use.
- Environmental and preconditioning tests: Humidity preconditioning, environmental conditions for testing and criteria for representative samples.
- Regulatory alignment: Clauses cross‑referenced to electrical standards (IEC 60601‑1) for electrical devices and to EU Directive 93/42/EEC for medical device conformity.
Applications
Who uses EN ISO 81060-1:2012 and why:
- Manufacturers and designers - to design, test and document non‑automated sphygmomanometers that meet recognized safety and performance expectations.
- Test laboratories and quality assurance teams - to perform type tests, accuracy verification and environmental conditioning in product development and production control.
- Clinical engineers and biomedical maintenance - to understand device limits, labelling and safe handling (mercury/aneroid precautions).
- Regulatory and compliance professionals - to support conformity assessment and demonstrate presumption of conformity to essential requirements of the EU medical device directive.
- Procurement and healthcare providers - to specify equipment that meets recognized standards for reliability and safety.
Related Standards
- EN ISO 81060‑2 - Clinical validation of automated measurement type (complements Part 1)
- IEC 60601‑1 - Electrical safety standard (referenced where electrical aspects apply)
- Replaces earlier EN 1060 series (superseded by this EN ISO edition)
Keywords: EN ISO 81060-1:2012, non-invasive sphygmomanometers, blood pressure measurement, non-automated sphygmomanometer requirements, test methods, device safety, accuracy testing.
Технические детали
- Технический комитет
- CEN/TC 205 - Non-active medical devices
- SKU
- EN ISO 81060-1:2012
Похожие стандарты
Стандарты, упомянутые в описании
ISO 81060-1:2007
ДействующийNon-invasive sphygmomanometers — Part 1: Requirements and test methods for non-automated measurement type
Overview ISO 81060-1:2007 defines safety, performance and test-method requirements for non-automated sphygmomanometers (manual blood pressure devices). The standard applies to devices that use inflat…
IEC 60601-1:2005
ДействующийMedical electrical equipment - Part 1: General requirements for basic safety and essential performance
Overview IEC 60601-1:2005 (Consolidated Edition 3.1, with Amendment 1) is the international safety standard for medical electrical equipment, defining the general requirements for basic safety and es…
ISO 81060-2:2018/AMD2:2024
ДействующийAmendment 2 - Non-invasive sphygmomanometers - Part 2: Clinical investigation of intermittent automated measu…
Overview ISO 81060-2:2018/AMD2:2024 is Amendment 2 to ISO 81060-2 (Non‑invasive sphygmomanometers - Part 2), updating clinical investigation requirements for intermittent automated blood‑pressure mea…