EN ISO 8362-7:2010 PDF
Injection containers and accessories - Part 7: Injection caps made of aluminium-plastics combinations without overlapping plastics part (ISO 8362-7:2006)
Injection containers and accessories - Part 7: Injection caps made of aluminium-plastics combinations without overlapping plastics part (ISO 8362-7:2006)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 11
- Дата публикации:
- 8 декабря 2010 г.
- Издание:
- CEN EN 8362 edition 1 version 1
- ICS:
- 11.040.20
ISO 8362-7:2006 specifies aluminium-plastics combinations for the injection caps of injection vials, as specified in ISO 8362-1 and ISO 8362-4, where the plastics part does not overlap the diameter of the vial body.
Abstract
Overview
EN ISO 8362-7:2010 is an international standard specifying requirements for injection caps made of aluminium-plastics combinations used in injection vials. This part of the ISO 8362 series focuses specifically on injection caps where the plastics component does not overlap the diameter of the vial body, ensuring compatibility with automated vial processing systems. Published by CEN and derived from ISO 8362-7:2006, the standard supports manufacturing consistency and safety in pharmaceutical packaging, particularly for transfusion, infusion, and injection equipment.
The standard applies to injection vials covered under ISO 8362-1 and ISO 8362-4 and aims to address challenges encountered during vial labeling and storage when overlapping plastics may cause process disruptions.
Key Topics
-
Scope and Application Specifies aluminium-plastics caps designed for injection vials with a non-overlapping plastics part, suited to prevent mechanical interference in automated processing.
-
Classification of Cap Types
- Type OB: Aluminium cap with a central opening, without overlapping plastics
- Type OD: Aluminium cap with a complete tear-off tab, without overlapping plastics
-
Dimensions and Tolerances Detailed dimensional specifications and tolerances aligned with ISO 2768-1 and ISO 2768-2 ensure standardization in cap sizing for nominal vial sizes (e.g., 13 mm and 20 mm).
-
Force Requirements Defines the force range for removing the plastics component and tearing off tabs, tested with calibrated devices (ISO 7500-1 compliant), critical for quality control and user safety.
-
Packaging and Marking Caps must be packaged according to ISO 8872 requirements and marked with standardized designations, facilitating traceability and regulatory compliance.
Applications
EN ISO 8362-7:2010 is primarily used in the medical and pharmaceutical industries for:
-
Primary Packaging of Injectable Drugs While injection caps themselves aren't direct-contact primary packaging, they are integral to securing injection vials, maintaining sterility and integrity.
-
Automated Manufacturing and Labeling Lines By preventing plastics from overlapping vial diameters, the caps optimize compatibility with automated vial labeling, storage, and handling equipment.
-
Transfusion, Infusion, and Injection Equipment Ensures standard interface components for medical injection devices, contributing to patient safety and equipment reliability.
-
Quality Control and Compliance Manufacturers use the standard for product specification, incoming inspection, and to meet international regulatory requirements for medical devices.
Related Standards
- ISO 8362-1: Injection vials made of glass tubing
- ISO 8362-3: Aluminium caps for injection vials
- ISO 8362-4: Injection vials made of moulded glass
- ISO 8362-6: Caps made of aluminium-plastics combinations with overlapping plastics part
- ISO 8872: Aluminium caps for transfusion, infusion, and injection bottles – general requirements and test methods
- ISO 2768-1 / ISO 2768-2: General tolerances for linear, angular, and geometrical dimensions
- ISO 7500-1: Verification and calibration of static uniaxial testing machines
By adhering to EN ISO 8362-7:2010, manufacturers and healthcare providers ensure the production and use of reliable, dimensionally consistent, and safe aluminium-plastics injection caps suitable for critical medical applications.
Keywords: injection caps, aluminium-plastics combinations, ISO 8362-7, injection vials, pharmaceutical packaging, medical device standards, non-overlapping plastics, vial caps, transfusion equipment, infusion equipment, pharmaceutical vial closure, medical packaging standards, CEN medical standards.
Технические детали
- Технический комитет
- CEN/TC 205 - Non-active medical devices
- SKU
- EN ISO 8362-7:2010
Похожие стандарты
Стандарты, упомянутые в описании
ISO 8362-7:2006
ДействующийInjection containers and accessories — Part 7: Injection caps made of aluminium-plastics combinations without…
Overview ISO 8362-7:2006 specifies design, dimensional and test requirements for injection caps made of aluminium‑plastics combinations where the plastics part does not overlap the diameter of the vi…
SIST EN ISO 8362-2:2024
ДействующийInjection containers and accessories - Part 2: Closures for injection vials (ISO 8362-2:2024)
Overview EN ISO 8362-2:2024 - "Injection containers and accessories - Part 2: Closures for injection vials" specifies shape, dimensions, materials, performance requirements and labelling for closures…
SIST EN ISO 8362-1:2019
ДействующийInjection containers and accessories - Part 1: Injection vials made of glass tubing (ISO 8362-1:2018)
Overview EN ISO 8362-1:2019 (ISO 8362-1:2018) defines the form, dimensions, capacities, materials and performance requirements for glass injection vials manufactured from glass tubing. It applies to…
SIST EN ISO 8362-4:2011
ДействующийInjection containers and accessories - Part 4: Injection vials made of moulded glass (ISO 8362-4:2011)
Overview - EN ISO 8362-4:2011 (Injection vials made of moulded glass) EN ISO 8362-4:2011 specifies the shape, dimensions, materials and performance requirements for moulded glass injection vials used…
SIST ISO 2768-1:1999
ДействующийGeneral tolerances -- Part 1: Tolerances for linear and angular dimensions without individual tolerance indic…
Overview SIST ISO 2768-1:1999 is an international standard published by the International Organization for Standardization (ISO) that specifies general tolerances for linear and angular dimensions wi…
ISO 2768-2:1989
ОтменёнGeneral tolerances — Part 2: Geometrical tolerances for features without individual tolerance indications
SIST EN ISO 7500-1:2018
ДействующийMetallic materials - Calibration and verification of static uniaxial testing machines - Part 1: Tension/compr…
Overview EN ISO 7500-1:2018 - "Metallic materials - Calibration and verification of static uniaxial testing machines - Part 1: Tension/compression testing machines - Calibration and verification of t…
SIST EN ISO 8872:2023
ДействующийAluminium caps and aluminium/plastic caps for infusion bottles and injection vials - General requirements and…
Overview EN ISO 8872:2022 - titled Aluminium caps and aluminium/plastic caps for infusion bottles and injection vials - General requirements and test methods - is a harmonized European adoption of IS…