IEC 60079-10-2:2015 PDF
Explosive atmospheres - Part 10-2: Classification of areas - Explosive dust atmospheres
Explosive atmospheres - Part 10-2: Classification of areas - Explosive dust atmospheres
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 92
- Дата публикации:
- 16 января 2015 г.
- Издание:
- IEC IS 60079 edition 2 version 1
- ICS:
- 29.260.20
IEC 60079-10-2:2015 is concerned with the identification and classification of areas where explosive dust atmospheres and combustible dust layers are present, in order to permit the proper assessment of ignition sources in such areas. In this standard, explosive dust atmospheres and combustible dust layers are treated separately. In Clause 4, area classification for explosive dusts clouds is described, with dust layers acting as one of the possible sources of release. In Clause 7 other general considerations for dust layers are described. The examples in this standard are based on a system of effective housekeeping being implemented in the plant to prevent dust layers from accumulating. Where effective housekeeping is not present, the area classification includes the possible formation of explosive dust clouds from dust layers. The principles of this standard can also be followed when combustible fibres or flyings might cause a hazard. This standard is intended to be applied where there can be a risk due to the presence of explosive dust atmospheres or combustible dust layers under normal atmospheric conditions. Please refer to the foreword of the document for a detailed listing of the significant technical changes from the previous edition. Keywords: explosive dust atmospheres, combustible dust layers, ignition hazards
Abstract
Overview - IEC 60079-10-2:2015 (Explosive dust atmospheres)
IEC 60079-10-2:2015 provides guidance for the identification and classification of areas where explosive dust atmospheres and combustible dust layers may be present, enabling correct assessment of ignition hazards and selection of appropriate protective measures. The standard treats dust clouds and dust layers separately (Clause 4 and Clause 7) and is intended for use under normal atmospheric conditions. It assumes effective housekeeping in the examples; where housekeeping is inadequate the classification must account for dust layers becoming sources of dust clouds.
Key topics and technical requirements
- Area classification procedure (Clause 4): step‑by‑step method to identify hazardous locations and determine appropriate zones for dust atmospheres.
- Sources of release (Clause 5): identification, grading and containment of dust releases, with emphasis on dust containment and continuous versus occasional releases.
- Zones for dust atmospheres (Clause 6): provision for classifying locations into Zone 20, Zone 21 and Zone 22 and guidance on the extent of these zones (see Table 1 and Clause 6.3).
- Dust layers (Clause 7): considerations for when layers can act as a release source or be re‑entrained into a cloud; housekeeping levels affect classification.
- Documentation and drawings (Clause 8): requirements for record keeping, preferred symbol keys for area classification, and the need to note Equipment Protection Levels (EPLs) on drawings.
- Competence of personnel (Clause 4.3): guidance that area classification must be performed by competent staff.
- Reference to related technical data sources (for example IEC 80079-20-2 for dust characteristics) is included where appropriate.
Practical applications
IEC 60079-10-2 is used to:
- Identify and map hazardous areas in facilities handling powders, dusts, fibres or flyings.
- Inform selection and installation of electrical and mechanical equipment suitable for dust zones (via EPLs and Ex-rated equipment).
- Design ventilation, containment and housekeeping programs to reduce ignition risks.
- Prepare area classification drawings, safety documentation and operational procedures.
- Support risk assessments for manufacturing, processing, storage and packaging operations (food, chemical, pharmaceutical, wood, metal powders, grain, etc.).
Who should use this standard
- Safety and process engineers performing area classification and risk assessments
- Plant designers and electrical engineers specifying Ex equipment
- Maintenance, operations and EHS teams responsible for housekeeping and documentation
- Certification bodies and consultants advising on combustible dust hazards
Related standards
- IEC 60079 series (Explosive atmospheres)
- IEC 80079-20-2 (referenced for dust characteristics)
- National/regional regulations and guidance on combustible dust safety
Keywords: explosive dust atmospheres, combustible dust layers, ignition hazards, area classification, Zone 20, Zone 21, Zone 22, IEC 60079-10-2.
Технические детали
- Технический комитет
- SC 31J - Classification of hazardous areas and installation requirements
- SKU
- IEC 60079-10-2:2015
Похожие стандарты
Упомянутые в описании и другие стандарты IEC
IEC 60079-25:2020/COR2:2022
ДействующийCorrigendum 2 - Explosive atmospheres - Part 25: Intrinsically safe electrical systems
IEC 60050-161:1990/AMD2:1998
ДействующийAmendment 2 - International Electrotechnical Vocabulary (IEV) - Part 161: Electromagnetic compatibility
IEC 60050-161:1990/AMD2:1998 – Electromagnetic Compatibility Vocabulary Amendment ### Overview The IEC 60050-161:1990/AMD2:1998 is the second amendment to the International Electrotechnical Vocabular…