IEC 60079-13:2017 PDF
Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"
Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 35
- Дата публикации:
- 22 мая 2017 г.
- Издание:
- IEC IS 60079 edition 2 version 1
- ICS:
- 29.260.20
IEC 60079-13:2017 gives requirements for the design, construction, assessment, verification and marking of rooms used to protect internal equipment: – located in a Zone 1 or Zone 2 or Zone 21 or Zone 22 explosive atmosphere without an internal source of gas/vapour release and protected by pressurization; – located in a Zone 2 explosive atmosphere with or without an internal source of gas/vapour release and protected by artificial ventilation; – located in a non-hazardous area, containing an internal source of gas/vapour release and protected by artificial ventilation; – located in a Zone 1 or Zone 2 or Zone 21 or Zone 22 explosive atmosphere containing an internal source of gas/vapour release and protected by both pressurization and artificial ventilation. The term "room" used in this document includes single rooms, multiple rooms, a complete building or a room contained within a building. A room is intended to facilitate the entry of personnel and includes inlet and outlet ducts. An acoustic hood and other like enclosures designed to permit the entry of personnel can be considered as a room. This document also includes requirements related safety devices and controls necessary to ensure that artificial ventilation, purging and pressurization is established and maintained. A room assembled or constructed on site, can be either on land or off-shore. The room is primarily intended for installation by an end-user but could be constructed and assessed at a manufacturer’s facility, where the final construction such as ducting can be completed on site. This document does not specify the methods that may be required to ensure adequate air quality for personnel with regard to toxicity and temperature within the room. National or other regulations and requirements may exist to ensure the safety of personnel in this regard. This second edition cancels and replaces the first edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) modification of the title of this document to include artificially ventilated room "v" in addition to pressurized room "p"; b) addition of types of protection "pb", "pc", and "vc" and removal of types of protection "px", "py", "pz" and "pv"; c) definition of the differences between pressurization and artificial ventilation types of protection; d) removal of protection of rooms with an inert gas or a flammable gas from the scope of this document; e) addition of an informative annex to include examples of applications where types of protection pressurization or artificial ventilation or pressurization and artificial ventilation can be used and associated guidelines.
Abstract
Overview
IEC 60079-13:2017 - Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" - gives requirements for the design, construction, assessment, verification and marking of rooms used to protect electrical and electronic equipment located in explosive atmospheres. The standard applies to single rooms, multi-room arrangements, whole buildings, acoustic hoods and similar enclosures that permit personnel entry and include inlet/outlet ducts. This is Edition 2.0 (2017) and represents a technical revision to the 2010 edition.
Key scope points:
- Protection of equipment inside rooms located in Zone 1/2 and Zone 21/22 explosive atmospheres using pressurization ("p"), artificial ventilation ("v"), or a combination of both.
- Rooms in non-hazardous areas that contain an internal source of gas/vapour release and are protected by artificial ventilation.
- Requirements for safety devices, control systems, purging, verification, marking and technical documentation.
Key topics and technical requirements
The standard addresses practical and technical elements necessary to achieve equipment protection in explosive atmospheres:
- Types of protection: Definitions and differences between pressurization ("p") and artificially ventilated ("v") rooms, and the introduced protection types such as pb, pc, vc.
- Design & construction: Room integrity, mechanical strength, penetrations, seals, personnel access doors, inlet/outlet ducts and HVAC considerations.
- Clean air supply: Sources of clean air, environmental conditions and integration with heating, ventilation and air conditioning systems.
- Pressurization-specific requirements: Pressurization systems, minimum pressure differentials, airlock arrangements, purging sequences, and actions on system failure.
- Artificial ventilation-specific requirements: Minimum flow rates, ventilation system design, safety actions for ventilation loss and purging procedures.
- Safety devices & controls: Gas detectors, safety interlocks, electrical disconnects, and verification of sequence of operations.
- Verification, testing & marking: Overpressure, purging, ventilation flow tests, confirmation of safety device ratings, marking and instruction documentation.
Practical applications and users
Who uses IEC 60079-13:
- Design and safety engineers specifying protective rooms for process plants, refineries, chemical and petrochemical facilities.
- Manufacturers and integrators of enclosures, acoustic hoods, packaged rooms, and modular onshore/offshore units.
- End‑users and facility operators implementing protected equipment rooms in Zones 1/2/21/22.
- Certification bodies, inspectors and maintenance teams responsible for verification, testing and periodic re‑assessment.
Typical applications:
- Enclosures for control and electrical equipment at gas turbine packages, pump skids, switchrooms, packaged plants and offshore modules where equipment must be isolated from surrounding explosive atmospheres.
Related standards
- IEC 60079 series (general explosive atmosphere standards) - consult IEC 60079-0 and other parts for complementary requirements, referenced normative documents and harmonized practices.
- National regulations on personnel air quality, toxicity and temperature may apply in addition to IEC 60079-13.
Технические детали
- Технический комитет
- SC 31J - Classification of hazardous areas and installation requirements
- SKU
- IEC 60079-13:2017
Похожие стандарты
Упомянутые в описании и другие стандарты IEC
IEC 60079-25:2020/COR2:2022
ДействующийCorrigendum 2 - Explosive atmospheres - Part 25: Intrinsically safe electrical systems
IEC 60079-0:2017/COR1:2020
ДействующийCorrigendum 1 - Explosive atmospheres - Part 0: Equipment - General requirements
IEC 60050-161:1990/AMD2:1998
ДействующийAmendment 2 - International Electrotechnical Vocabulary (IEV) - Part 161: Electromagnetic compatibility
IEC 60050-161:1990/AMD2:1998 – Electromagnetic Compatibility Vocabulary Amendment ### Overview The IEC 60050-161:1990/AMD2:1998 is the second amendment to the International Electrotechnical Vocabular…