IEC 60228:2004 PDF
Conductors of insulated cables
Conductors of insulated cables
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 19
- Дата публикации:
- 2 ноября 2004 г.
- Издание:
- IEC IS 60228 edition 3 version 1
- ICS:
- 29.060.20
Specifies the nominal cross-sectional areas, in the range 0,5 mm2 to 2 500 mm2, for conductors in electric power cables and cords of a wide range of types. Requirements for numbers and sizes of wires and resistance values are also included. These conductors include solid and stranded copper, aluminium and aluminium alloy conductors in cables for fixed installations and flexible copper conductors. The standard does not apply to conductors for telecommunication purposes. The applicability of this standard to a particular type of cable is as specified in the standard for the type of cable. Unless indicated to the contrary in a particular clause, this standard relates to the conductors in the finished cable and not to the conductor as made or supplied for inclusion into a cable. Informative annexes are included giving supplementary information covering temperature correction factors for resistance measurement (Annex B) and dimensional limits of circular conductors (Annex C). The principal changes with respect to the previous edition are as follows: a) the consolidation of material from IEC 60228A; b) addition of a definition for nominal cross-sectional area; c) an increase in the range of conductor sizes in Tables 1 and 2; d) addition of a note that solid aluminum alloy conductors, having the same dimensions as aluminum conductors, will have a higher resistance; e) strengthening of the recommendations for dimensional limits of compacted stranded copper conductors.
Abstract
Overview
IEC 60228:2004 - "Conductors of insulated cables" is an international standard from the IEC (Technical Committee 20) that defines nominal conductor sizes, construction classes and resistance limits for conductors used in electric power cables and cords. The standard covers nominal cross‑sectional areas from 0.5 mm² to 2 500 mm², and includes solid and stranded copper, aluminium and aluminium alloy conductors for fixed installations and flexible copper conductors for cords. It does not apply to telecommunication conductors. Informative annexes provide temperature correction factors for resistance measurement (Annex B) and dimensional guidance for circular conductors (Annex C).
Key topics and technical requirements
- Nominal cross‑sectional areas: Standard sizes and the definition of nominal cross‑sectional area as an identifying value (0.5 mm² – 2 500 mm²).
- Conductor classes: Classification into Class 1 (solid), Class 2 (stranded), Class 5 and 6 (flexible), with intended uses for fixed and flexible cables.
- Materials and mechanical limits: Requirements for plain or metal‑coated annealed copper, aluminium and aluminium alloy conductors; tensile strength limits for solid and stranded aluminium wires where specified.
- Construction rules: Minimum numbers of wires, uniform wire diameters, limits on wire diameter ratios, and guidance on compacted and shaped stranded conductors.
- Electrical resistance: Maximum permissible resistance values measured at 20 °C (detailed in Tables 1–4), including a note that aluminium alloy conductors with the same dimensions as aluminium will have higher resistance (factor guidance provided).
- Testing & measurement: Clause references and Annex A/B for resistance measurement procedures and temperature correction factors.
- Dimensional guidance: Annex C gives recommended dimensional limits for circular conductors and strengthened guidance for compacted stranded copper.
Applications and users
IEC 60228 is a fundamental reference for:
- Cable designers and manufacturers for specifying conductor construction, sizes and resistance.
- Test laboratories and certification bodies verifying compliance with conductor resistance and construction classes.
- Standards committees and procurement/specification writers who reference conductor requirements in cable product standards.
- Electrical engineers and installers who need to match conductor performance (resistance, flexibility) to application requirements.
Note: For specific cable types, applicability is governed by the corresponding cable standard. The standard also includes practical conversion and usage notes (e.g., AWG/kcmil references used in some countries).
Related standards
- IEC 60228 is intended as a base reference for IEC cable product standards developed by IEC TC 20. For selection and full applicability, consult the specific cable type standard referenced by IEC or national regulations.
Технические детали
- Технический комитет
- TC 20 - Electric cables
- SKU
- IEC 60228:2004
Похожие стандарты
Упомянутые в описании и другие стандарты IEC
IEC 60228:2023
ДействующийConductors of insulated cables
Overview IEC 60228:2023 - "Conductors of insulated cables" - is the fourth edition (2023) International Electrotechnical Commission (IEC) standard that defines the nominal metric conductor sizes, con…
IEC 60050-161:1990/AMD2:1998
ДействующийAmendment 2 - International Electrotechnical Vocabulary (IEV) - Part 161: Electromagnetic compatibility
IEC 60050-161:1990/AMD2:1998 – Electromagnetic Compatibility Vocabulary Amendment ### Overview The IEC 60050-161:1990/AMD2:1998 is the second amendment to the International Electrotechnical Vocabular…