IEC 60287-3-2:2012 PDF
Electric cables - Calculation of the current rating - Part 3-2: Sections on operating conditions - Economic optimization of power cable size
Electric cables - Calculation of the current rating - Part 3-2: Sections on operating conditions - Economic optimization of power cable size
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 77
- Дата публикации:
- 4 июля 2012 г.
- Издание:
- IEC IS 60287 edition 2 version 1
- ICS:
- 29.060.20
IEC 60287-3-2:2012 sets out a method for the selection of a cable size taking into account the initial investments and the future costs of energy losses during the anticipated operational life of the cable. Matters such as maintenance, energy losses in forced cooling systems and time of day energy costs have not been included in this standard. Two examples of the application of the method to hypothetical supply systems are given in Annex A.
Abstract
Overview
IEC 60287-3-2:2012 is an international standard published by the International Electrotechnical Commission (IEC) that addresses the economic optimization of power cable size. This part of the IEC 60287 series focuses specifically on selecting electric cable sizes by balancing the initial investment costs with the future costs of energy losses over the cable’s anticipated operational life. Unlike traditional cable sizing approaches that prioritize minimal initial cost, this standard promotes a comprehensive cost evaluation that considers the total cost of ownership, thereby enabling more sustainable and economically efficient decisions in cable design and selection.
This standard does not include factors such as maintenance costs, energy losses in forced cooling systems, or variable time-of-day energy pricing. It provides calculation methods and examples to support electrical engineers and designers in optimizing cable conductor sizes for power systems based on a long-term cost perspective.
Key Topics
-
Economic Cable Sizing The standard introduces a method for calculating the economic size of electric cables by integrating both capital expenditure (purchase and installation costs) and operational expenditure (energy loss costs during usage). This balanced approach ensures cost-effective investment in cable infrastructure.
-
Cost of Energy Losses Energy losses, especially joule losses caused by conductor resistance at operating temperatures, constitute a significant portion of operational expenses. IEC 60287-3-2 guides practitioners in estimating these losses and their financial impact over time.
-
Discounting Future Costs To compare initial costs and future loss-related costs, the standard applies discounting techniques to convert future costs into present values. This ensures an accurate economic comparison by accounting for the cost of borrowing money and inflation neutrality.
-
Calculation Procedures It provides mathematical models and formulae to estimate total costs, economic current ranges, and the optimum conductor cross-sectional area. Both AC and DC system applications are supported, with adjustments detailed for DC resistance and loss factors.
-
Practical Examples Annex A of the document includes detailed examples illustrating applications to hypothetical supply systems, demonstrating calculation steps and decision criteria.
Applications
-
Power Distribution Systems Utilities and power engineers can utilize the standard to optimize cable sizes in distribution networks, minimizing lifecycle costs while ensuring operational reliability.
-
Industrial Electrical Installations Designers of large industrial power systems can apply economic optimization to balance upfront cable costs with energy efficiency over operational life, reducing total costs.
-
Infrastructure Projects Infrastructure planners for commercial, residential, or transport projects can use this standard to make cost-effective decisions about cable sizing that consider future energy costs.
-
Energy Efficiency Initiatives Organizations aiming to improve energy efficiency and reduce operating expenses will benefit from applying IEC 60287-3-2 to guide investments in cable infrastructure.
Related Standards
-
IEC 60287 Series The economic optimization standard is part of the IEC 60287 series on calculation of current ratings in electric cables. Other parts cover thermal, electrical, and environmental operating conditions affecting cable performance.
-
IEC 60502 For technical specifications on power cables including construction and testing relevant for cable installation and operation.
-
ISO/IEC Directives, Part 2 Governs the drafting of IEC standards and ensures methodological consistency including economic factors such as discounting.
By integrating initial and operational cost assessments, IEC 60287-3-2:2012 supports optimized cable sizing decisions that lead to significant cost savings-potentially up to 50% over the cable lifecycle. This enhances both economic and environmental sustainability in electrical power systems.
Технические детали
- Технический комитет
- TC 20 - Electric cables
- SKU
- IEC 60287-3-2:2012
Похожие стандарты
Стандарты, упомянутые в описании
BS IEC 60287-2-1:2015
ОтменёнElectric cables. Calculation of the current rating - Thermal resistance. Calculation of thermal resistance
What is BS IEC 60287-2-1 – Calculation of thermal resistance about? BS IEC 60287-2-1 is an international standard on electric cables and the calculation of the current rating. BS IEC 60287-2-1 presen…
BS IEC 60287-3-2:2012
Electric cables. Calculation of the current rating - Sections on operating conditions. Economic optimization…
What is BS IEC 60287-3-2 - Economic optimization of power cable size about? BS IEC 60287-3-2 is a British Standard for the selection of cable size taking into account the initial investments and the…
IEC 60502-4:2010
ДействующийPower cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to…
Overview IEC 60502-4:2010 is an international standard developed by the International Electrotechnical Commission (IEC) that specifies test requirements for accessories used with power cables featuri…