IEC 60601-2-35:2020 PDF
Medical electrical equipment - Part 2-35: Particular requirements for the basic safety and essential performance of heating devices using blankets, pads and mattresses and intended for heating in medical use
Medical electrical equipment - Part 2-35: Particular requirements for the basic safety and essential performance of heating devices using blankets, pads and mattresses and intended for heating in medical use
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 70
- Дата публикации:
- 21 декабря 2023 г.
- Издание:
- IEC IS 60601 edition 2 version 1
- ICS:
- 11.040.01
IEC 60601-2-35:2020 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of HEATING DEVICES using BLANKETS, PADS or MATTRESSES in medical use, also referred to as ME EQUIPMENT. HEATING DEVICES intended to prewarm a bed are included in the scope of this document. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. If a clause or subclause is specifically intended to be applicable to a specifically defined type of ME EQUIPMENT, as is the case with FORCED AIR DEVICES, then the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this document are not covered by specific requirements in this document, except in 7.2.13 and 8.4.1 of the general standard. IEC 60601-2-35:2020 does not apply to: - HEATING DEVICES intended for physiotherapy; - INFANT RADIANT WARMERS; for information, see IEC 60601-2-21; - INFANT INCUBATORS; for information, see IEC 60601-2-19; - INFANT TRANSPORT INCUBATORS, for information, see IEC 60601-2-20; - cooling devices. IEC 60601-2-35:2020 cancels and replaces IEC 80601-2-35 published in 2009 and Amendment 1:2016. This edition constitutes a technical revision. IEC 60601-2-35:2020 includes the following significant technical change with respect to the previous edition: re-dating of normative references.
Abstract
Overview
IEC 60601-2-35:2020 is the particular part of the IEC 60601 series that defines the basic safety and essential performance requirements for medical electrical heating devices using blankets, pads or mattresses. Edition 2.0 (2020) is a technical revision that cancels and replaces IEC 80601-2-35 (2009) and its 2016 amendment. The standard covers devices intended for patient heating in medical use, including devices intended to prewarm beds, and applies to both ME EQUIPMENT and ME SYSTEMS unless a clause explicitly limits applicability.
Key topics and requirements
- Scope & exclusions: Applies to heating blankets, pads and mattresses; excludes physiotherapy heating devices, infant radiant warmers and incubators (see IEC 60601-2-21 / -2-19 / -2-20), and cooling devices.
- Safety & essential performance: Requirements for preventing electrical, thermal and mechanical hazards during normal use and specified fault conditions.
- Temperature controls and limits: Requirements and test procedures for contact surface temperature, average and maximum temperatures, and time-dependent temperature limits to avoid patient burns.
- Heat transfer testing: Normative annexes provide methods for determining heat transfer toward/away from the patient and conditions for adequate heat discharge.
- Forced air devices: Specific clauses and normative test procedures (including maximum contact surface temperature tests and single-fault condition tests) for forced air warming systems.
- Construction & labeling: Identification, marking, instructions for use and guidance specific to heated surfaces (sensor placement, folding, partial covering).
- Electromagnetic compatibility (EMC) and alarm systems: EMC requirements for ME EQUIPMENT and ME SYSTEMS and guidance/tests for alarm behaviour.
- Programmable systems: Requirements when the device includes programmable electrical medical systems (PEMS).
- Testing & documentation: General and device-specific testing requirements, plus normative and informative annexes that detail test apparatus and procedures.
Applications and who uses it
- Manufacturers and design engineers use IEC 60601-2-35 to design compliant heating blankets, pads, mattresses and forced-air warmers.
- Test laboratories and certification bodies apply the normative tests and annex procedures to assess conformity.
- Regulatory affairs and quality teams reference the standard for conformity files, risk management and labeling requirements.
- Hospitals and procurement specialists use the standard to evaluate device safety, compatibility and intended clinical applications.
- Clinical engineers and maintenance teams use the guidance for safe operation, alarms and EMC considerations.
Related standards
- IEC 60601-1 (General requirements for basic safety and essential performance)
- IEC 60601-1-2 (EMC)
- IEC 60601-2-19 / -2-20 / -2-21 (infant incubators, transport incubators, radiant warmers) - referenced for excluded device types
Keywords: IEC 60601-2-35:2020, medical electrical equipment, heating devices, blankets, pads, mattresses, basic safety, essential performance, forced air devices, contact surface temperature, EMC, PEMS.
Технические детали
- Технический комитет
- SC 62D - Particular medical equipment, software, and systems
- SKU
- IEC 60601-2-35:2020
Похожие стандарты
Стандарты, упомянутые в описании
IEC 60601-2-33:2010/COR1:2012
ДействующийCorrigendum 1 - Medical electrical equipment - Part 2-33: Particular requirements for the basic safety and es…
IEC 60601-2-21:2020
ДействующийMedical electrical equipment - Part 2-21: Particular requirements for the basic safety and essential performa…
Overview IEC 60601-2-21:2020 is an internationally recognized standard that specifies the particular requirements for the basic safety and essential performance of infant radiant warmers - electrical…
IEC 60601-2-35:1996
Medical electrical equipment - Particular requirements for the safety of blankets, pads and mattresses intend…
PD IEC/TR 62296:2009
ДействующийConsiderations of unaddressed safety aspects in the second edition of IEC 60601-1 and proposals for new requi…
What is PD IEC/TR 62296 - Considerations of unaddressed safety aspects in the second edition of IEC 60601-1 about? PD IEC/TR 62296 is a technical report that discusses the considerations of unaddress…
IEC 60601-1:2005
ДействующийMedical electrical equipment - Part 1: General requirements for basic safety and essential performance
Overview IEC 60601-1:2005 (Consolidated Edition 3.1, with Amendment 1) is the international safety standard for medical electrical equipment, defining the general requirements for basic safety and es…
IEC 60601-2-19:2020
ДействующийMedical electrical equipment - Part 2-19: Particular requirements for the basic safety and essential performa…
Overview IEC 60601-2-19:2020 is the third edition (2020) particular standard in the IEC 60601 series that specifies the basic safety and essential performance requirements for infant incubators - a c…