IEC 61000-4-3:2020 PDF
Electromagnetic compatibility (EMC) - Part 4-3 : Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
Electromagnetic compatibility (EMC) - Part 4-3 : Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 81
- Дата публикации:
- 8 сентября 2020 г.
- Издание:
- IEC IS 61000 edition 4 version 1
- ICS:
- 33.100.20
IEC 61000-4-3:2020 is applicable to the immunity requirements of electrical and electronic equipment to radiated electromagnetic energy. It establishes test levels and the required test procedures. The object of this document is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to radiated, radio-frequency electromagnetic fields. The test method documented in this part of IEC 61000 describes a consistent method to assess the immunity of an equipment or system against RF electromagnetic fields from RF sources not in close proximity to the EUT. The test environment is specified in Clause 6. NOTE 1 As described in IEC Guide 107, this is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and if applied, they are responsible for determining the appropriate test levels and performance criteria. TC 77 and its sub-committees are prepared to co-operate with product committees in the evaluation of the value of particular immunity tests for their products. NOTE 2 Immunity testing against RF sources in close proximity to the EUT is defined in IEC 61000-4-39. Particular considerations are devoted to the protection against radio-frequency emissions from digital radiotelephones and other RF emitting devices. NOTE 3 Test methods are defined in this part for evaluating the effect that electromagnetic radiation has on the equipment concerned. The simulation and measurement of electromagnetic radiation is not adequately exact for quantitative determination of effects. The test methods defined in this basic document have the primary objective of establishing an adequate reproducibility of testing configuration and repeatability of test results at various test facilities. This document is an independent test method. It is not possible to use other test methods as substitutes for claiming compliance with this document. This fourth edition cancels and replaces the third edition published in 2006, Amendment 1:2007 and Amendment 2:2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - testing using multiple test signals has been described; - additional information on EUT and cable layout has been added; - the upper frequency limitation has been removed to take account of new services; - the characterization of the field as well as the checking of power amplifier linearity of the immunity chain are specified.
Abstract
Overview
IEC 61000-4-3:2020 - "Electromagnetic compatibility (EMC) - Part 4‑3: Testing and measurement techniques - Radiated, radio‑frequency, electromagnetic field immunity test" - defines a standardized method to assess the immunity of electrical and electronic equipment to radiated RF electromagnetic fields. The 2020 (4th) edition is a technical revision that clarifies test procedures, removes the previous upper frequency limit to reflect new RF services, and adds guidance on multi‑signal testing, EUT/cable layout and field/chain characterization.
Key topics and technical requirements
- Scope & objective: Establishes common reference test levels and reproducible procedures for evaluating equipment immunity to RF fields from sources not in close proximity to the EUT.
- Test levels and frequency ranges: Provides criteria for selecting test levels and frequency sweep ranges; this edition removed the upper frequency cap to cover emerging services.
- Test environment & equipment: Specifies requirements for test facilities (open‑area and anechoic chambers), Uniform Field Area (UFA) dimensions and characteristics, antennas, amplifiers and instrumentation.
- Field generation and characterization: Defines methods for level setting (constant field or constant power), field uniformity checks, and E‑field probe calibration (see Annex K).
- Amplifier linearity & harmonic control: Requires checking amplifier linearity and limiting harmonics to ensure the applied field is accurate (Annex D).
- Test setups: Detailed layout guidance for table‑top, floor‑standing, human‑body‑mounted and large/heavy EUTs, including cable routing and accessory arrangement (Annexes G, H).
- Test execution & evaluation: Step sizes, laboratory reference conditions, test sequence, evaluation of EUT performance and standardized test reporting.
- New features in 2020: Description of testing with multiple test signals, extended guidance on cable/EUT layout, and explicit procedures for field and immunity chain characterization.
- Support material: Informative annexes covering intermodulation, measurement uncertainty, probe calibration methods and rationale for modulation choices (e.g., 80% AM).
Applications and who uses this standard
- EMC test laboratories performing radiated immunity testing and certification.
- Product designers and manufacturers ensuring device robustness against ambient RF fields (consumer electronics, industrial control, medical devices, telecommunications equipment).
- Regulatory bodies and product committees using the standard as a reference to set product‑specific immunity requirements (IEC Guide 107 cooperation noted).
- System integrators and compliance engineers designing test plans, lab setups, and evaluating field immunity performance.
Related standards
- IEC 61000‑4‑39 - Immunity testing for RF sources in close proximity to the EUT (complements Part 4‑3 for near‑field scenarios).
- IEC Guide 107 - Guidance on basic EMC publications and product committee responsibilities.
Keywords: IEC 61000‑4‑3, radiated immunity, EMC testing, RF immunity test, uniform field area, anechoic chamber, field probe calibration, amplifier linearity.
Технические детали
- Технический комитет
- SC 77B - High frequency phenomena
- SKU
- IEC 61000-4-3:2020
Похожие стандарты
Упомянутые в описании и другие стандарты IEC
IEC 61000-4-39:2017
ДействующийElectromagnetic compatibility (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in clos…
Overview IEC 61000-4-39:2017 is an international standard developed by the International Electrotechnical Commission (IEC). It sets out specific immunity requirements and testing procedures for elect…
IEC 61000-4-30:2015/COR1:2016
ДействующийCorrigendum 1 - Electromagnetic compatibility (EMC) - Part 3-40: Testing and measurement techniques - Power q…
IEC 60050-161:1990/AMD2:1998
ДействующийAmendment 2 - International Electrotechnical Vocabulary (IEV) - Part 161: Electromagnetic compatibility
IEC 60050-161:1990/AMD2:1998 – Electromagnetic Compatibility Vocabulary Amendment ### Overview The IEC 60050-161:1990/AMD2:1998 is the second amendment to the International Electrotechnical Vocabular…