IEC 61300-2-55:2017 PDF
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-55: Tests - Strength of mounted adaptor
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-55: Tests - Strength of mounted adaptor
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 15
- Дата публикации:
- 9 марта 2017 г.
- Издание:
- IEC IS 61300 edition 1 version 1
- ICS:
- 01
IEC 61300-2-55:2017 describes the test procedure to measure the mounting strength of an optical adaptor or receptacle to a fixture.
Abstract
Overview
IEC 61300-2-55:2017 specifies a test procedure to measure the mounting strength of a fibre optic adaptor or receptacle when fixed to a panel or fixture. Part of the IEC 61300 series on basic test and measurement procedures, this standard defines how to apply and measure axial loads on mounted adaptors to verify mechanical integrity and resistance to mounting forces. Typical targets include SC, LC and MPO adaptors using the cut-out guidance in Annex A.
Keywords: IEC 61300-2-55, strength of mounted adaptor, fibre optic adaptor test, optical adaptor mounting strength, SC LC MPO adaptor.
Key topics and technical requirements
- Scope: Test procedure for axial loading of an adaptor or receptacle mounted in a fixture or panel.
- Loading methods: Two defined methods for force application:
- Method A - load applied via a holding fixture coupled to the DUT (e.g., connector plug) and force gauge.
- Method B - load applied directly to the DUT via the force gauge.
- Apparatus:
- Force generator capable of smooth application at specified rate.
- Force gauge with specified uncertainty to record axial load.
- Holding fixture (for Method A) designed to avoid compressive deformation.
- Rigid fixture/panel with cut-outs (Annex A provides dimensions for SC, LC, MPO).
- Timer to measure duration of applied load.
- Procedure steps:
- Pre-conditioning (≥ 2 h under standard atmospheric conditions).
- Initial visual examination and measurements (see IEC 61300-3-1).
- Mounting the DUT and applying axial load at specified rate to the specified force and holding for the required duration.
- Recovery (10 min under standard conditions) followed by final visual inspection for cracking, permanent deformation or other damage.
- Recommended severity (when not otherwise specified): Category C, U, E - 70 N, 5 N/s rate, 10 s duration (categories defined in IEC 61753-1).
- Details to specify in a product or test specification: method (A or B), applied force, rate, duration, fixture cut-out and panel thickness, pass/fail criteria.
Applications and users
- Who uses it: fibre optic component manufacturers, test laboratories, QA and reliability engineers, product designers, and procurement/certification teams.
- Practical uses:
- Product qualification and acceptance testing of adaptors and receptacles.
- Verification of panel-mounted adaptor robustness in telecom, datacom and datacenter equipment.
- Ensuring mechanical reliability for installation and field handling.
- Supporting compliance claims and supplier evaluations.
Related standards
- IEC 61300-1 - General and guidance for basic test procedures.
- IEC 61300-3-1 - Visual examination and measurements.
- IEC 61754 series - Connector interface dimensions (SC, MPO, LC).
- IEC 61753-1 - Defines performance categories referenced for severity values.
This standard helps ensure that mounted optical adaptors meet repeatable, industry-recognized mechanical strength criteria, improving interoperability and long-term reliability of fibre optic installations.
Технические детали
- Технический комитет
- SC 86B - Fibre optic interconnecting devices and passive components
- SKU
- IEC 61300-2-55:2017
Похожие стандарты
Стандарты, упомянутые в описании
IEC 61300-2-50:2007/COR1:2015
ДействующийCorrigendum 1 - Fibre optic interconnecting devices and passive components - Basic test and measurement proce…
IEC 61300-3-14:2025
ДействующийFibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-1…
Overview IEC 61300-3-14:2025 specifies a standardized method to measure the error and repeatability of the attenuation settings of a Variable Optical Attenuator (VOA). The fourth edition updates proc…
IEC 61753-1:2018/COR1:2019
ДействующийCorrigendum 1 - Fibre optic interconnecting devices and passive components - Performance standard - Part 1: G…
IEC 61300-1:2016
ДействующийFibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 1:…
IEC 61300-1:2016 Overview IEC 61300-1:2016 is an international standard published by the International Electrotechnical Commission (IEC) that provides general information and guidance for basic test…