IEC 61300-3-42:2007 PDF
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-42: Examinations and measurements - Attenuation of single mode alignment sleeves and or adaptors with resilient alignment sleeves
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-42: Examinations and measurements - Attenuation of single mode alignment sleeves and or adaptors with resilient alignment sleeves
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 21
- Дата публикации:
- 27 ноября 2007 г.
- Издание:
- IEC IS 61300 edition 1 version 1
- ICS:
- 33.180.20
This part of IEC 61300 describes the method to measure the attenuation of single mode adaptors with resilient sleeves and the attenuation of resilient sleeves.
Abstract
Overview
IEC 61300-3-42:2007 is an international standard published by the International Electrotechnical Commission (IEC) that specifies the method for measuring attenuation in fibre optic interconnecting devices and passive components. This part of the IEC 61300 series focuses specifically on attenuation of single mode alignment sleeves and adaptors equipped with resilient alignment sleeves. It provides essential guidelines to accurately determine the signal loss caused by these components through basic test and measurement procedures.
The standard ensures consistent, reliable measurements for optical losses in single mode fibre optic assemblies, facilitating quality assurance and interoperability in fibre optic systems.
Key Topics
-
Attenuation Measurement The standard defines attenuation as the decrease in optical power, expressed in decibels (dB), caused by the insertion of a device under test (DUT). It accounts for the lateral offset between fibre cores, sleeve geometry, and ferrule outer diameter interactions.
-
Test Apparatus and Conditions
- Light Source: Utilizes a single-mode LED source with specific wavelength and spectral width, avoiding polarization sensitivity effects.
- Power Meter: Requires a highly stable optical power meter with accuracy ±5%, linearity within ±0.02 dB, and a large sensitive area compatible with the fibre numerical aperture.
- Reference Plugs: Special reference plugs are used to form complete assemblies. These plugs must adhere to IEC 61754 and IEC 61755-3 specifications to minimize measurement error from angular misalignment or mode field diameter mismatch.
-
Measurement Procedure Includes pre-conditioning of the device, visual inspection for defects, and a detailed attenuation measurement protocol. Measurements are carried out by comparing input power (P0) and output power (P1) through the DUT, with precautions to maintain fibre position and avoid bending losses.
-
Precautions for Accurate Testing
- Optical power should be kept below 0 dBm to prevent nonlinear scattering effects.
- Fibre connectors must be fixed in position between measurements to avoid added attenuation due to movement or bending.
- Relative rotation between plugs must be less than 5° to ensure consistent results.
Applications
IEC 61300-3-42:2007 is vital for manufacturers, testing laboratories, and quality assurance teams working with fibre optic components, including:
-
Fibre Optic Network Deployment Ensuring minimal signal loss through connectors and adaptors in single mode fibre networks such as telecommunications, data centers, and high-speed internet infrastructures.
-
Component Qualification Verifying compliance of resilient alignment sleeves and single mode adaptors with performance specifications prior to installation.
-
Research and Development Assisting engineers in the design and improvement of optical interconnecting devices to achieve lower attenuation rates and higher reliability.
-
Standardized Testing Providing a universally accepted methodology to compare attenuation results across different products and vendors, supporting interoperability and certification.
Related Standards
- IEC 61300-1:2003 – Basic test and measurement procedures: General and guidance for fibre optic interconnecting devices and passive components.
- IEC 61300-3-1 – Visual examination of fibre optic devices.
- IEC 61300-3-35 PAS – Visual inspection of fibre optic cylindrical connector endfaces.
- IEC 61754 (all parts) – Fibre optic connector interfaces defining connector family specifications.
- IEC 61755-3 (all parts) – Fiber optic connector optical interfaces detailing endface geometry and optical interface requirements.
For further information and access to the full IEC 61300 series, visit the IEC official website or contact your local IEC National Committee.
Keywords: IEC 61300-3-42, fibre optic attenuation measurement, single mode adaptors, resilient alignment sleeves, optical connector testing, IEC fibre optic standards, fibre optic interconnection components, optical power meter, fibre optic quality assurance.
Технические детали
- Технический комитет
- SC 86B - Fibre optic interconnecting devices and passive components
- SKU
- IEC 61300-3-42:2007
Похожие стандарты
Стандарты, упомянутые в описании
IEC 61300-2-50:2007/COR1:2015
ДействующийCorrigendum 1 - Fibre optic interconnecting devices and passive components - Basic test and measurement proce…
IEC 61754-13:2024/COR1:2025
ДействующийCorrigendum 1 - Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces…
IEC 61755-3-1:2006/COR1:2009
ДействующийCorrigendum 1 - Fibre optic connector optical interfaces - Part 3-1: Optical interface, 2,5 mm and 1,25 mm di…
IEC 61300-3-14:2025
ДействующийFibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 3-1…
Overview IEC 61300-3-14:2025 specifies a standardized method to measure the error and repeatability of the attenuation settings of a Variable Optical Attenuator (VOA). The fourth edition updates proc…