IEC 61347-1:2015/AMD1:2017 PDF
Amendment 1 - Lamp controlgear - Part 1: General and safety requirements
Amendment 1 - Lamp controlgear - Part 1: General and safety requirements
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 16
- Дата публикации:
- 29 сентября 2017 г.
- Издание:
- IEC IS 61347 edition 3 version 1
- ICS:
- 29.030
Defines the grades of grain-oriented electrical steel sheet in nominal thicknesses of 0,23 mm, 0.27 mm, 0.30 mm and 0.35 mm. Gives general requirements, magnetic properties, geometric characteristics and tolerances, and technological characteristics, as well as inspection procedures. Applies to Goss textured grain-oriented electrical steel sheet supplied in the final annealed condition in sheets or coils, and intended for the construction of magnetic circuits.
Abstract
Overview
IEC 61347-1:2015/AMD1:2017 is an important amendment to the international standard covering lamp controlgear - specifically Part 1, which deals with general and safety requirements. Published by the International Electrotechnical Commission (IEC), this amendment enhances and updates the requirements for lamp controlgear that operate on d.c. supplies up to 1000 V and/or a.c. supplies up to 1000 V at 50 Hz or 60 Hz. The document is essential for manufacturers, designers, and safety inspectors involved in the production and testing of electrical equipment used in lighting systems worldwide.
This standard amendment focuses on the integration of surge protective devices (SPDs), marking and identification requirements, terminal compliance, insulation and moisture resistance, clearing distances, temperature limits, and fault conditions. It also builds on existing IEC norms to provide clearer guidelines on safety and performance to ensure reliability and proper protection against electrical hazards in lamp controlgear.
Key Topics
-
Scope Enhancement This amendment defines the comprehensive general and safety requirements applicable to lamp controlgear for both a.c. and d.c. supplies up to 1000 volts.
-
Surge Protective Devices (SPD) Introduction and definition of SPDs in lamp controlgear for transient overvoltage protection. Requirements for marking “Integrated SPD,” ensuring that these devices are clearly identifiable and meet protection criteria per IEC 61643-11.
-
Marking and Identification Updates on mandatory markings include the protective earth symbol and SELV (Safety Extra Low Voltage) circuits identification. Requirements detail readability and compliance with IEC 60417-5019 for earth markings.
-
Terminal Requirements Integral and non-integral terminals must meet IEC 60598-1 standards for screw and screwless terminals. Additional terminal standards referenced include IEC 60947-7-4, IEC 60838-2-2, and IEC 60998, ensuring proper application and safety.
-
Insulation and Creepage Distances Clarifications on the use of capacitors and resistors bridging conductive parts separated by double or reinforced insulation are provided. The amendment specifies minimum clearance distances for working voltages and impulse withstand categories (II and III), crucial to prevent electrical breakdown, especially in polluted environments.
-
Moisture Resistance and Dielectric Strength Insulation and strength tests require disconnecting SPDs during testing in accordance with IEC 61643-11 to maintain reliability and safety under operating conditions.
-
Temperature Classification and Heating The amendment updates temperature limits for various components (capacitors, windings, bobbins) based on material classification standards IEC 60085 and IEC 60317-0-1, ensuring thermal safety in normal use.
-
Fault Conditions and Testing Specifies testing protocols for short circuits and high-power supply faults with currents up to 160 A rms, improving robustness and safe failure modes of lamp controlgear.
Applications
IEC 61347-1:2015/AMD1:2017 applies to manufacturers and developers of lamp controlgear used across a wide range of lighting applications, including:
- Fluorescent and discharge lamps
- LED lighting modules with integrated controlgear
- Industrial, commercial, and residential lighting systems
- Surge-protected lighting equipment critical for environments exposed to transient overvoltage
- Electrical devices requiring adherence to strict safety and insulation parameters for operation at high voltages (up to 1000 V)
Adhering to this amendment supports compliance with international safety standards, facilitating global market acceptance and improving user safety through standardized design and testing.
Related Standards
For full compliance and comprehensive lamp controlgear design, this amendment references and complements these IEC standards:
- IEC 60598-1 - General requirements for luminaires, including terminals.
- IEC 61643-11 - Low-voltage surge protective devices - requirements and testing.
- IEC 60947-7-4 - PCB terminal blocks for copper conductors.
- IEC 60838-2-2 - Connectors for LED modules.
- IEC 61048 - Safety requirements for capacitors used in lamp circuits.
- IEC 60998 (all parts) - Connecting devices for low-voltage circuits in household and similar applications.
- IEC 60085 & IEC 60317-0-1 - Insulation and thermal classification of electrical components.
These interrelated standards align to provide a robust safety and quality framework for lamp controlgear used in various electrical lighting products.
Keywords: IEC 61347-1 amendment, lamp controlgear safety, surge protective device, SPD, electrical insulation, creepage distances, terminal standards IEC, lamp controlgear marking, low-voltage surge protection, electrical safety standards, lighting controlgear requirements.
Технические детали
- Технический комитет
- SC 34C - Auxiliaries for lamps
- SKU
- IEC 61347-1:2015/AMD1:2017
Похожие стандарты
Стандарты, упомянутые в описании
IEC 61347-1:2015
ДействующийLamp controlgear - Part 1: General and safety requirements
Overview IEC 61347-1:2015 - "Lamp controlgear - Part 1: General and safety requirements" - establishes the general and safety requirements for lamp controlgear intended for use on d.c. supplies up to…
IEC 61643-11:2011
ДействующийLow-voltage surge protective devices - Part 11: Surge protective devices connected to low-voltage power syste…
Overview IEC 61643-11:2011 is an international standard published by the International Electrotechnical Commission (IEC) that defines the requirements and test methods for low-voltage surge protectiv…
IEC 60598-1:2014/COR2:2015
ДействующийCorrigendum 2 - Luminaires - Part 1: General requirements and tests
IEC 60947-7-4:2019
ДействующийLow-voltage switchgear and controlgear - Part 7-4: Ancillary equipment - PCB terminal blocks for copper condu…
Overview IEC 60947-7-4:2019 is the IEC international standard for PCB terminal blocks for copper conductors, part of the Low‑voltage switchgear and controlgear series. It specifies construction, perf…
IEC 60998-2-3:2002/COR1:2006
ДействующийCorrigendum 1 - Connecting devices for low-voltage circuits for household and similar purposes - Part 2-3: Pa…
IEC 60085:2007
ДействующийElectrical insulation - Thermal evaluation and designation
Overview IEC 60085:2007, Electrical Insulation – Thermal Evaluation and Designation, is a key international standard published by the International Electrotechnical Commission (IEC). This standard se…
IEC 60317-0-10:2017
ДействующийSpecifications for particular types of winding wires - Part 0-10: General requirements - Polyester glass-fibr…
Overview IEC 60317-0-10:2017 sets forth the general requirements for polyester glass-fibre wound fused, unvarnished, or resin or varnish impregnated, bare or enamelled round copper winding wires. Pub…