IEC 61467:2008 PDF
Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests
Insulators for overhead lines - Insulator strings and sets for lines with a nominal voltage greater than 1 000 V - AC power arc tests
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 81
- Дата публикации:
- 12 августа 2008 г.
- Издание:
- IEC IS 61467 edition 1 version 1
- ICS:
- 29.080.10
IEC 61467:2008 applies to insulator strings and sets comprising string insulator units of ceramic material, glass or composite material for use on a.c. overhead lines and traction lines with a nominal voltage above 1 000 V and a frequency between 15 Hz and 100 Hz. This standard also applies to insulator strings or sets of similar design used in substations. This standard establishes a standard test procedure for power arc tests on insulator sets. It also establishes a standard test procedure for power arc tests on short strings. This standard does not apply to insulator sets mounted on non-metallic poles or towers. This edition cancels and replaces IEC/TR 61467, which was published as a technical report in 1997. It constitutes a technical revision and now has the status of an International Standard.
Abstract
Overview
IEC 61467:2008 is an international standard established by the International Electrotechnical Commission (IEC) that specifies test procedures for insulator strings and sets used on overhead lines with a nominal voltage greater than 1,000 V AC. The standard covers insulator units made from ceramic, glass, or composite materials intended for use on AC overhead and traction lines operating at frequencies between 15 Hz and 100 Hz. It also applies to similar insulator strings or sets used in substations but excludes sets mounted on non-metallic poles or towers.
The core focus of IEC 61467:2008 is the AC power arc testing of insulator strings and sets. It defines standard procedures to simulate and evaluate the performance of these insulators under power arc conditions, which are critical for ensuring electrical safety and reliability in high-voltage transmission systems. This edition supersedes the earlier technical report IEC/TR 61467 from 1997 and upgrades it to full international standard status with revised technical content.
Key Topics
- Scope of application: Covers insulator strings for nominal voltages above 1,000 V AC, frequencies 15 Hz to 100 Hz, including overhead lines, traction lines, and substations.
- Materials covered: Ceramic, glass, and composite insulator units.
- Test procedures: Prescribes standardized methods for conducting power arc tests on both full insulator sets and short insulator strings.
- Test criteria: Establishes evaluation benchmarks for test results including visual inspection and performance acceptance criteria.
- Limitations: Does not include insulator sets on non-metallic poles or towers and is not directly applicable to line post insulators and insulating structures.
- Test conditions: Details supply and return circuit conditions, arc initiation methods, ambient conditions, and test current characteristics.
- Supplementary information: Contains comprehensive examples of test arrangements, determination of current measurements, and guidelines for test reporting.
Applications
IEC 61467:2008 is vital for manufacturers, testing laboratories, electrical utilities, and engineering consultants involved in the design, testing, and certification of insulators used in high-voltage overhead transmission and traction networks. Key practical applications include:
- Quality assurance and validation: Ensures insulator strings meet rigorous AC power arc withstand requirements to guarantee line reliability.
- Safety assurance: Helps identify potential failure modes under electrical arc stress, reducing risk of outages and hazards.
- Research and development: Assists in developing new insulator materials and designs optimized for withstand capabilities against power arcs.
- Compliance testing: Provides a harmonized test protocol for complying with international electrical safety standards.
- Substation equipment vetting: Applies to insulator sets in substations exposed to transient arc conditions.
Related Standards
- IEC 60797: Addresses residual strength testing of string insulators after mechanical damage, complementing IEC 61467 by focusing on mechanical resilience.
- IEC 60826: Covers design criteria for overhead transmission lines, providing overarching guidelines that align with insulator testing standards.
- IEC 60050-471: Provides definitions for high-voltage electrical terms relevant to insulator testing.
- IEC 60383-1 and IEC 60383-2: Define specifications for insulator units including test requirements and mechanical strength considerations.
Keywords: IEC 61467, AC power arc tests, insulator strings, overhead lines, high-voltage insulators, ceramic insulators, glass insulators, composite insulators, test procedures, electrical insulator standards, power arc testing, overhead transmission line insulators, insulator set testing, international electrotechnical standards.
Технические детали
- Технический комитет
- TC 36 - Insulators
- SKU
- IEC 61467:2008
Похожие стандарты
Стандарты, упомянутые в описании
BS IEC 60826:2017
ДействующийOverhead transmission lines. Design criteria
What is BS IEC 60826 – Overhead transmission lines about? BS IEC 60826 is an international standard that discusses design criteria for overhead transmission lines. Overhead power lines are used to tr…
IEC 60050-471:2007/AMD1:2015
ДействующийAmendment 1 - International Electrotechnical Vocabulary (IEV) - Part 471: Insulators
IEC 60383-1:2023
ДействующийInsulators for overhead lines with a nominal voltage above 1000 V - Part 1: Ceramic or glass insulator units…
Overview IEC 60383-1:2023 is an international standard issued by the International Electrotechnical Commission (IEC) focusing on ceramic and glass insulators for overhead power lines operating at nom…