IEC 61726:2015 PDF
Cable assemblies, cables, connectors and passive microwave components - Screening attenuation measurement by the reverberation chamber method
Cable assemblies, cables, connectors and passive microwave components - Screening attenuation measurement by the reverberation chamber method
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 16
- Дата публикации:
- 8 сентября 2015 г.
- Издание:
- IEC IS 61726 edition 3 version 1
- ICS:
- 33.120.10
IEC 61726:2015 describes the measurement of screening attenuation by the reverberation chamber test method, sometimes named mode stirred chamber, suitable for virtually any type of microwave component and having no theoretical upper frequency limit. It is only limited toward low frequencies due to the size of the test equipment, which is frequency-dependent and is only one of several methods of measuring screening attenuation. For the purpose of this standard, examples of microwave components are waveguides, phase shifters, diplexers/multiplexers, power dividers/combiners etc. This third edition cancels and replaces the second edition, published in 1999. This edition constitutes a technical revision. It takes into account the latest developments in the design of reverberation chambers as described in IEC 61000-4-21, which is also referencing this standard as a possible test method. Furthermore, an alternative measurement procedure is added which is able to reduce the measurement time needed.
Abstract
Overview
IEC 61726:2015 specifies the reverberation chamber (mode‑stirred chamber) method for measuring screening attenuation of cable assemblies, cables, connectors and passive microwave components. The standard defines how to expose a device under test (DUT) to an almost homogeneous, isotropic electromagnetic field inside a high‑Q shielded cavity and how to quantify the power coupled into the DUT. IEC 61726:2015 is the third edition (replacing the 1999 edition) and updates procedures in line with modern reverberation chamber design and faster measurement options.
Key topics and technical requirements
- Measurement principle: Screening attenuation is determined by comparing power induced into the DUT with the reference field in the chamber (direct power ratio or using the chamber insertion loss).
- Reverberation chamber design: Chamber must comply with IEC 61000‑4‑21 requirements; avoid perfect cubic shape; use conductive, non‑lossy materials.
- Mode stirrer: Large relative to wavelength; minimum size guidance-at least two wavelengths tip‑to‑tip at the lowest test frequency.
- Antennas: Input and reference antennas with limited resonances and minimal loss; return loss better than 6 dB recommended. Isotropic field conditions reduce directionality effects.
- Calibration and controls: Verify insertion loss of cavity, dynamic range, VSWR, and use of calibrators. The standard includes both a standard measurement and a fast measurement procedure to reduce test time.
- Frequency applicability: No theoretical upper frequency limit; practical lower frequency limit is set by chamber size (sufficient modes-e.g., ≥100 modes at lowest test frequency).
- Evaluation: Includes relation between transfer impedance/transfer functions and screening attenuation for electrically short or distributed leakage scenarios.
Applications and who uses it
- Manufacturers and test labs performing screening attenuation and EMC characterization of:
- Waveguides, phase shifters, diplexers/multiplexers
- Power dividers/combiners, passive microwave components
- Cable assemblies, coaxial cables and RF connectors
- EMC engineers and compliance laboratories using reverberation chamber testing to validate shielding performance across wide microwave frequency ranges.
- R&D teams evaluating enclosure, connector and cable leakage where traditional low‑frequency methods are inadequate.
Related standards
- IEC 61000‑4‑21 - Reverberation chamber test methods (design and calibration guidance)
- IEC 61196‑1 - Coaxial communication cables (definitions and requirements)
- IEC TS 62153‑4‑1 - Introduction to electromagnetic screening measurements
Keywords: IEC 61726:2015, reverberation chamber, screening attenuation, mode‑stirred chamber, microwave components, cable assemblies, EMC testing, insertion loss, shielding measurement.
Технические детали
- Технический комитет
- TC 46 - Cables, wires, waveguides, RF connectors, RF and microwave passive components and accessories
- SKU
- IEC 61726:2015
Похожие стандарты
Упомянутые в описании и другие стандарты IEC
IEC 61000-4-21:2011
ДействующийElectromagnetic compatibility (EMC) - Part 4-21: Testing and measurement techniques - Reverberation chamber t…
Overview IEC 61000-4-21:2011 is a key international standard developed by the International Electrotechnical Commission (IEC) that focuses on Electromagnetic Compatibility (EMC). This standard outlin…
IEC 61196-10:2014/COR1:2016
ДействующийCorrigendum 1 - Coaxial communication cables - Part 10: Sectional specification for semi-rigid cables with po…
IEC 60050-161:1990/AMD2:1998
ДействующийAmendment 2 - International Electrotechnical Vocabulary (IEV) - Part 161: Electromagnetic compatibility
IEC 60050-161:1990/AMD2:1998 – Electromagnetic Compatibility Vocabulary Amendment ### Overview The IEC 60050-161:1990/AMD2:1998 is the second amendment to the International Electrotechnical Vocabular…