IEC 61970-456:2021 PDF
Energy management system application program interface (EMS-API) - Part 456: Solved power system state profiles
Energy management system application program interface (EMS-API) - Part 456: Solved power system state profiles
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 217
- Дата публикации:
- 15 декабря 2021 г.
- Издание:
- IEC IS 61970 edition 3 version 1
- ICS:
- 33.200
IEC 61970-456:2021 belongs to the IEC 61970-450 to IEC 61970-499 series that, taken as a whole, defines at an abstract level the content and exchange mechanisms used for data transmitted between power system analyses applications, control centres and/or control centre components. The purpose of this document is to rigorously define the subset of classes, class attributes, and roles from the CIM necessary to describe the result of state estimation, power flow and other similar applications that produce a steady-state solution of a power network, under a set of use cases which are included informatively in this document. This document is intended for two distinct audiences, data producers and data recipients, and can be read from those two perspectives. From the standpoint of model export software used by a data producer, the document defines how a producer may describe an instance of a network case in order to make it available to some other program. From the standpoint of a consumer, the document defines what that importing software must be able to interpret in order to consume power flow cases. There are many different use cases for which use of this document is expected and they differ in the way that the document will be applied in each case. Implementers are expected to consider what use cases they wish to cover in order to know the extent of different options they must cover. As an example, the profiles defined in this document will be used in some cases to exchange starting conditions rather than solved conditions, so if this is an important use case, it means that a consumer application needs to be able to handle an unsolved state as well as one which has met some solution criteria. This third edition cancels and replaces the second edition published in 2018. This edition constitutes a technical revision. It is based on the IEC 61970 UML version ‘IEC61970CIM17v40’, dated 2020-08-24. This edition includes the following significant technical changes with respect to the previous edition: a) Updated to support CIM17 (IEC 61970-301:2020+AMD1) and align with IEC 61970‑452:ED4. b) The classes PowerElectronicsConnection, PowerElectronicsUnit and PowerElectronicsWindUnit are added to the Steady State Hypothesis (SSH) profile to match the changes done for Edition 4 of IEC 61970-452 , Core Equipment profile. c) Added relevant terms used in this document. d) Clarified use of Equipment.inService and Equipment.normallyInService.
Abstract
Overview
IEC 61970-456:2021 is a key international standard developed by the International Electrotechnical Commission (IEC) focused on defining the Energy Management System Application Program Interface (EMS-API) for solved power system state profiles. This document is part of the IEC 61970 series, specifically falling within the 450 to 499 range, which collectively standardize the abstract content and exchange methods used for data transmission between power system analysis applications, control centers, and related components.
The primary goal of IEC 61970-456:2021 is to rigorously specify the subset of the Common Information Model (CIM) classes, their attributes, and roles essential to describing results from state estimation, power flow, and other steady-state power system analysis applications. By defining these profiles, the standard facilitates seamless data exchange between producers and consumers of power system state solutions.
This third edition, which supersedes the 2018 second edition, aligns with the updated CIM17 version and includes significant technical enhancements to support evolving power system components such as power electronics and wind units. It targets two main audiences: data producers who export the network cases and data consumers who import and utilize solved power flow cases.
Key Topics
-
Steady-State Solution Representation Defines how steady-state solutions from state estimation and power flow applications are modeled and exchanged, including solved and unsolved network states.
-
CIM Profile Subset Specifies the required CIM classes, attributes, and roles necessary for representing power system states, focusing on interoperability.
-
Data Producer and Consumer Perspectives Details model export considerations for data producers and necessary interpretation capabilities for data consumers.
-
Updated Support for CIM17 and Power Electronics Inclusion of new classes such as PowerElectronicsConnection, PowerElectronicsUnit, and PowerElectronicsWindUnit for more accurate modeling of modern grids.
-
Use Case Flexibility Supports a range of use cases including EMS network analysis integration, power flow-based network analysis, model partitioning, and boundary modeling.
-
Topology and Connectivity Modeling Includes specifications for bus-branch, node-breaker models, and connectivity profiles to accurately represent network architecture.
-
Data Modeling Examples Provides CIMXML examples to illustrate topology processing and state profile exchanges.
Applications
IEC 61970-456:2021 serves crucial roles in the energy management industry by enabling:
-
Interoperability Between Power System Analysis Tools Ensuring consistent data exchange of solved power system states across diverse software platforms used by utilities and system operators.
-
Improved EMS Integration Allowing Energy Management Systems (EMS) to incorporate accurate steady-state network profiles from multiple sources, improving situational awareness.
-
Facilitation of Model Partitioning Supports dividing large network models into manageable partitions with defined boundaries, enhancing analysis and planning activities.
-
Enhanced Grid Modernization Efforts By integrating power electronics and renewable generation modeling, the standard helps accommodate the evolving dynamics of modern smart grids.
-
Data Exchange for Power Flow and State Estimation Streamlines the sharing of solutions that inform operational decisions, contingency analysis, and grid reliability assessments.
Related Standards
-
IEC 61970-301:2020 (CIM Core Model) Provides the foundational Common Information Model structure upon which the EMS-API profiles build.
-
IEC 61970-450 to IEC 61970-499 Series Covers the broader suite of EMS-API standards, encompassing various data exchange and interface aspects for power system applications.
-
IEC 61970-452 (Core Equipment Profile) Closely related for equipment modeling, recently updated to support power electronics components aligning with IEC 61970-456 revisions.
-
IEC 61970-455 (Topology Profiles) Complements IEC 61970-456 by detailing topology modeling essential for accurate network state solutions.
IEC 61970-456:2021 is essential for utilities, system operators, software vendors, and engineers engaging in power system state estimation and analysis. Its clear framework for exchanging solved power system state profiles promotes interoperability, reliability, and efficiency across modern electric grid management systems.
Технические детали
- Технический комитет
- TC 57 - Power systems management and associated information exchange
- SKU
- IEC 61970-456:2021
Похожие стандарты
Стандарты, упомянутые в описании
IEC 61970-301:2020
ДействующийEnergy management system application program interface (EMS-API) - Part 301: Common information model (CIM) b…
IEC 61970-301:2020 - Overview IEC 61970-301:2020 defines the Common Information Model (CIM) base for the Energy Management System Application Program Interface (EMS-API). The CIM is an abstract, vend…
BS EN IEC 61970-457:2024
ДействующийEnergy management system application program interface (EMS-API) - Dynamics profile
IEC 61970-452:2021
ДействующийEnergy management system application program interface (EMS-API) - Part 452: CIM static transmission network…
Overview IEC 61970-452:2021 is an international standard developed by the International Electrotechnical Commission (IEC) that defines a static transmission network model profile as part of the Energ…
IEC 61970-456:2018
ДействующийEnergy management system application program interface (EMS-API) - Part 456: Solved power system state profil…
Overview IEC 61970-456:2018 is an international standard developed by the International Electrotechnical Commission (IEC) that specifies energy management system application program interfaces (EMS-A…