Electricity metering data exchange - The DLMS/COSEM suite - Part 8-4: Communication profiles for narrow-band OFDM PLC PRIME neighbourhood networks
Electricity metering data exchange - The DLMS/COSEM suite - Part 8-4: Communication profiles for narrow-band OFDM PLC PRIME neighbourhood networks
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 159
- Дата публикации:
- 13 декабря 2018 г.
- Издание:
- IEC IS 62056 edition 1 version 1
- ICS:
- 17.220.20
IEC 62056-8-4:2018 specifies DLMS/COSEM communication profiles for narrow-band OFDM power line carrier PRIME neighbourhood networks using the modulation as specified in Recommendation ITU-T G.9904:2012. Three communication profiles are specified: • a profile using the IEC 61334-4-32 LLC layer; • a profile using TCP-UDP/IPv4; • a profile using TCP-UDP/IPv6.
Abstract
Overview
IEC 62056-8-4:2018 is an International Electrotechnical Commission (IEC) standard that defines specific communication profiles within the DLMS/COSEM suite for narrow-band Orthogonal Frequency Division Multiplexing (OFDM) Power Line Carrier (PLC) PRIME neighbourhood networks. These communication profiles are essential for facilitating efficient and standardized electricity metering data exchange over low voltage power lines, supporting smart metering infrastructure and advanced metering deployments.
This standard leverages modulation techniques defined in ITU-T G.9904:2012 and ensures interoperability and stability across multiple network configurations by specifying three distinct communication profiles, each integrating DLMS/COSEM functionality with the PRIME PLC framework.
Key Topics
- DLMS/COSEM Communication Profiles: IEC 62056-8-4 details three profiles for robust electricity metering data exchange over PRIME networks:
- IEC 61334-4-32 Logical Link Control (LLC) layer: Designed for direct adaptation between PRIME network layers and the DLMS/COSEM application.
- TCP-UDP/IPv4: Uses Internet Protocol version 4 to enable connectivity and scalable communication between devices and networks.
- TCP-UDP/IPv6: Incorporates Internet Protocol version 6 for enhanced address space and modern networking features.
- PRIME OFDM PLC Technology: Utilizes narrow-band OFDM modulation for reliable data transmission over existing low voltage electricity distribution networks, enhancing communication between meters and head-end systems.
- Protocol Stack Architecture: Specifies the use of common lower layers (PHY and MAC), convergence layers, and application layers from the DLMS/COSEM suite, ensuring layered approach for flexibility and integration with existing systems.
- Registration and Management: Outlines node registration, addressing schemes, and connection management, supporting seamless neighborhood network operation and device association with the network.
- Security and Interoperability: References security mechanisms at the application and lower protocol layers to maintain data integrity and confidentiality, as well as ensuring device and network interoperability.
Applications
IEC 62056-8-4:2018 has practical relevance in the following areas:
- Smart Metering Infrastructure: Enables standardized data communication between electricity meters and utility management systems over power line networks, supporting functions like remote meter reading, firmware upgrades, and load management.
- Advanced Metering Infrastructure (AMI): Forms a key foundation for AMI by providing a communication method that scales to large neighbourhood deployments without requiring new cabling.
- Utility Data Collection and Management: Supports utilities in achieving reliable, real-time metering data collection for billing, demand response, and network diagnostics.
- Interoperability Across Devices: Ensures a unified approach for different manufacturers and device types to communicate seamlessly within PRIME PLC networks using standardized protocols.
- Future-proof Networking: By supporting both IPv4 and IPv6, utility companies can gradually transition to modern IP-based systems, future-proofing their infrastructure investments.
Related Standards
IEC 62056-8-4:2018 references and works in conjunction with several key standards within the DLMS/COSEM suite and affiliated protocol standards to ensure holistic and integrated functionality. Key related standards include:
- IEC 62056-1-0: Smart metering standardization framework
- IEC TS 62056-1-1: Templates for DLMS/COSEM communication profile standards
- IEC 62056-4-7: DLMS/COSEM transport layer for IP networks
- IEC 62056-5-3: DLMS/COSEM application layer
- IEC 62056-6-1 & IEC 62056-6-2: Object identification system and interface classes
- IEC 62056-9-7: Communication profile for TCP-UDP/IP networks
- IEC 61334-4-32: Logical Link Control (LLC) sub-layer protocols
- ITU-T G.9904:2012: Narrow-band OFDM power line communication for PRIME networks
- Relevant IETF RFCs and TCP/IP standards (e.g., RFC792, RFC768, RFC2460, RFC4862) for comprehensive protocol stack requirements
Together, these standards create a comprehensive ecosystem for reliable, secure, and interoperable electricity metering and data exchange over narrow-band OFDM PLC PRIME neighbourhood networks.
Технические детали
- Технический комитет
- TC 13 - Electrical energy measurement and control
- SKU
- IEC 62056-8-4:2018
Похожие стандарты
Стандарты, упомянутые в описании
BS EN IEC 62056-8-4:2019
ДействующийElectricity metering data exchange. the DLMS/COSEM suite - Communication profiles for narrow-band OFDM PLC PR…
What is BS EN IEC 62056 ‑ 8 ‑ 4 - Electricity metering data exchange about? BS EN IEC 62056 discusses electricity metering data exchange. BS EN IEC 62056 ‑ 8 ‑ 4 belongs to BS EN IEC 62056 multi-seri…
IEC 61334-4-32:1996
ДействующийDistribution automation using distribution line carrier systems - Part 4: Data communication protocols - Sect…
Overview IEC 61334-4-32:1996 is an international standard published by the International Electrotechnical Commission (IEC) that specifies requirements for the Logical Link Control (LLC) sublayer as p…
IEC 62056-1-0:2014
ДействующийElectricity metering data exchange - The DLMS/COSEM suite - Part 1-0: Smart metering standardisation framework
Overview IEC 62056-1-0:2014 titled Electricity Metering Data Exchange - The DLMS/COSEM Suite - Part 1-0: Smart Metering Standardisation Framework is an international standard published by the Interna…
IEC 62056-47:2006
Electricity metering - Data exchange for meter reading, tariff and load control - Part 47: COSEM transport la…
IEC 62056-5-3:2017
ДействующийElectrcity metering data exchange - The DLMS/COSEM suite - Part 5-3: DLMS/COSEM application layer
Overview IEC 62056-5-3:2017 specifies the DLMS/COSEM application layer used for electricity metering data exchange. It defines the structure, services and protocol behavior for DLMS/COSEM clients and…
IEC 62056-61:2006
Electricity metering - Data exchange for meter reading, tariff and load control - Part 61: Object identificat…
BS EN IEC 62056-6-2:2018
ОтменёнElectricity metering data exchange. The DLMS/COSEM suite - COSEM interface classes
What is BS EN IEC 62056 ‑ 6 ‑ 2 - COSEM interface classes about? BS EN IEC 62056 discusses electricity metering data exchange. BS EN IEC 62056 ‑ 6 ‑ 2 is the sixth part of BS EN IEC 62056 multi-serie…
IEC 62056-9-7:2013
ДействующийElectricity metering data exchange - The DLMS/COSEM suite - Part 9-7: Communication profile for TCP-UDP/IP ne…
Overview IEC 62056-9-7:2013 is an international standard specifying the DLMS/COSEM communication profile for TCP-UDP/IP networks. This standard is a critical part of the IEC 62056 series, which cover…