IEC 62153-4-17:2018 PDF
Metallic cables and other passive components - Test methods - Part 4-17: Electromagnetic compatibility (EMC) - Reduction Factor
Metallic cables and other passive components - Test methods - Part 4-17: Electromagnetic compatibility (EMC) - Reduction Factor
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 21
- Дата публикации:
- 15 августа 2018 г.
- Издание:
- IEC IS 62153 edition 1 version 1
- ICS:
- 33.120.10
IEC 62153-4-17:2018 applies to the testing of the reduction factor of multi-element metallic cables used in analogue and digital communication and control. The described method is generally applicable to all screened metallic cables. The reduction factor describes the screening effectiveness of a cable screen at frequencies below 1 kHz with a ratio of voltages describing the screened and unscreened situation. During the measurement, the cable under test is connected to a specific current loop arrangement.
Abstract
Overview
IEC 62153-4-17:2018, published by the International Electrotechnical Commission (IEC), establishes standardized test methods to determine the reduction factor of multi-element metallic cables and other passive components with a screen. This standard is a crucial part of electromagnetic compatibility (EMC) testing and is generally applicable to all screened metallic cables used in analogue and digital communication and control systems. The reduction factor measures the effectiveness of a cable's screen against electromagnetic interference at frequencies below 1 kHz, ensuring reliable data transmission and signal integrity in various electrical and electronic environments.
Key Topics
- Reduction Factor Definition: The reduction factor describes the ratio of voltages measured in screened versus unscreened conditions of a metallic cable, providing a quantifiable measure of the cable screen's effectiveness in attenuating low-frequency electromagnetic fields.
- Test Procedures: IEC 62153-4-17 outlines the setup and execution of tests, including sample preparation, required equipment (such as adjustable AC sources, voltmeters, and current transformers), and measurement steps performed with specific current loop arrangements and controlled environmental conditions.
- Test Conditions and Setup: The test is typically conducted at a room temperature of 20 °C ±10 °C and 55% ±25% relative humidity. Cables under test are placed on a non-conductive table, away from metallic objects, and are demagnetized prior to measurement to avoid interference.
- Expression of Results: Results are evaluated using the voltage ratio (reduction factor) between the internal (screened) and external (unscreened) situations, ensuring that the effectiveness of the screen meets the cable's technical specification requirements.
Applications
IEC 62153-4-17:2018 is widely recognized in fields where electromagnetic compatibility and signal integrity of communication and control cables are critical:
- Communication Infrastructure: Ensures that screened metallic cables used in telecommunication networks and LANs reliably protect data signals against external electromagnetic interference, which is essential for seamless operation in both analogue and digital systems.
- Industrial Automation and Control: Provides a standardized method for verifying the EMC performance of control cables in automated manufacturing environments, minimizing the risk of process interruptions due to electromagnetic disturbances.
- Railways and Power Systems: Used in qualifying cables installed in environments exposed to strong electromagnetic fields, such as electrified railway lines and high-voltage installations, supporting safe and stable communications and control operations.
- Product Type Testing and Quality Assurance: Serves as a type test during cable design, production, and quality control phases, helping manufacturers and engineers demonstrate compliance with EMC regulations and maintain high product reliability.
Related Standards
Several related international and regional standards address aspects of EMC testing and cable screening effectiveness, including:
- IEC 62153 Series: A comprehensive multi-part standard covering test methods for metallic cables and passive components, supporting a consistent approach to EMC testing (see other parts for tests at other frequency ranges or screening methods).
- ITU-T Recommendation K.26: Focuses on the protection of telecommunication lines against adverse effects from electrical power and electrified railways, referencing similar test approaches for reduction factor assessment.
- DIN VDE 0472-507: German standard outlining additional procedures for verifying the reduction factor of cables.
- NF F07-024: French standard specific to the measurement of reduction factor at 50 Hz for railway signal and telecom cables.
Practical Value
Adherence to IEC 62153-4-17:2018 ensures that manufacturers, system integrators, and operators can select and validate cables that meet rigorous EMC requirements, reducing risks of signal degradation and electromagnetic interference in mission-critical environments. This contributes directly to the reliability and performance of modern communication, automation, and safety systems, underlining the importance of standardized test methods for metallic cable screening effectiveness. For those involved in electrical engineering, cabling infrastructure, and EMC compliance, understanding and applying this standard is essential for product development, procurement, and quality assurance.
Технические детали
- Технический комитет
- TC 46 - Cables, wires, waveguides, RF connectors, RF and microwave passive components and accessories
- SKU
- IEC 62153-4-17:2018
Похожие стандарты
Упомянутые в описании и другие стандарты IEC
BS IEC 62153-4-17:2018
ДействующийMetallic cables and other passive components. Test methods - Electromagnetic compatibility (EMC). Reduction F…
What is BS IEC 62153 ‑ 4 ‑ 17 - Metallic cables and other passive components about? BS IEC 62153 is a series on metallic cables and other passive components. Metallic cable is a cable consisting of s…
IEC 62153-4-16:2021/COR1:2023
ДействующийCorrigendum 1 - Metallic cables and other passive components test methods - Part 4-16: Electromagnetic compat…
IEC 60050-161:1990/AMD2:1998
ДействующийAmendment 2 - International Electrotechnical Vocabulary (IEV) - Part 161: Electromagnetic compatibility
IEC 60050-161:1990/AMD2:1998 – Electromagnetic Compatibility Vocabulary Amendment ### Overview The IEC 60050-161:1990/AMD2:1998 is the second amendment to the International Electrotechnical Vocabular…