IEC 62217:2012 PDF
Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 52
- Дата публикации:
- 27 сентября 2012 г.
- Издание:
- IEC IS 62217 edition 2 version 1
- ICS:
- 29.080.10
IEC 62217:2012 is applicable to polymeric insulators whose insulating body consists of one or various organic materials. Polymeric insulators covered by this standard include both solid core and hollow insulators. They are intended for use on HV overhead lines and in indoor and outdoor equipment. The object of this standard is: - to define the common terms used for polymeric insulators; - to prescribe common test methods for design tests on polymeric insulators; - to prescribe acceptance or failure criteria, if applicable. These tests, criteria and recommendations are intended to ensure a satisfactory life-time under normal operating and environmental conditions. This standard shall only be applied in conjunction with the relevant product standard. This second edition cancels and replaces the first edition published in 2005. This edition constitutes a technical revision. This edition includes a significant technical change with respect to the previous edition. The first edition of IEC 62217 (2005) included two other alternative tracking and erosion tests (a 5 000 hour multi-stress test and a tracking wheel test) which were based on tests developed by CIGRE and utilities. These tests are no longer given as normative alternatives following the results of a study/questionnaire by TC 36 on the relative merits of all three tracking and erosion tests. The 5 000 hour multi-stress test and a tracking wheel test are described in IEC/TR 62730 (2012).
Abstract
Overview
IEC 62217:2012 is an international standard developed by the International Electrotechnical Commission (IEC) that focuses on polymeric high-voltage (HV) insulators intended for both indoor and outdoor use. This standard specifies general definitions, test methods, and acceptance criteria to ensure the reliable performance and durability of polymeric insulators under normal operating and environmental conditions. It applies to insulators with insulating bodies made of one or multiple organic materials and covers both solid core and hollow types. IEC 62217:2012 provides a comprehensive framework for manufacturers, testing laboratories, and utility companies to validate the design and quality of polymeric HV insulators.
Key Topics
-
Scope and Applicability The standard targets polymeric HV insulators used on high-voltage overhead lines and in indoor/outdoor electrical equipment. It defines common terminology and test procedures relevant to various polymeric insulator constructions.
-
General Definitions Provides a unified language and classification system for polymeric insulators, aiding consistent communication and documentation in testing and product design.
-
Design and Test Methods IEC 62217 details standardized test methods including:
- Mechanical and electrical design tests
- Tests on interfaces and end fittings
- Hardness and materials testing for sheds and housings
- Accelerated weathering and 1,000-hour salt fog tracking and erosion test
- Porosity and water diffusion tests on core materials
- Flammability testing according to specific criteria
-
Acceptance and Failure Criteria Clear criteria are prescribed for test acceptance or rejection to ensure insulator reliability over its operational life. This helps manufacturers avoid designs or materials that may fail prematurely.
-
Technical Updates The 2012 edition is a technical revision that replaces the first edition from 2005. It withdraws older tracking and erosion test alternatives (5,000-hour multi-stress and tracking wheel tests) based on findings from IEC Technical Committee 36. These alternatives are now described in IEC/TR 62730.
Applications
IEC 62217:2012 is fundamental for ensuring the quality and durability of polymeric HV insulators used in:
-
High-Voltage Overhead Transmission Lines The standard guarantees that insulators will withstand the environmental stresses associated with outdoor electrical transmission systems.
-
Indoor HV Equipment Polymeric insulators within switchgear, transformers, and other indoor high-voltage apparatus benefit from standardized testing to confirm performance under different indoor conditions.
-
Utilities and Energy Providers Provides a reliable benchmark for performance during procurement, maintenance, and quality assurance processes.
-
Insulator Manufacturers and Test Laboratories Ensures consistent production quality, facilitates international market access, and underpins innovation of polymeric insulator materials and designs.
Related Standards
-
IEC 60507 and IEC 61245 Standards on pollution testing of insulators which are referenced but noted as requiring further study for polymeric materials.
-
IEC/TR 62730:2012 Technical report describing the 5,000-hour multi-stress test and tracking wheel test methods that were once normative alternatives but now serve as complementary testing resources.
-
IEC Guide 111 Provides guidelines for reliability testing and lifetime prediction, which influenced the development and structure of IEC 62217.
Practical Value
Adopting IEC 62217:2012 enables enhanced reliability and safety of high-voltage electrical systems by:
- Enforcing consistent, internationally recognized test protocols that confirm material and design integrity.
- Supporting lifetime performance assessment under realistic environmental conditions.
- Facilitating interoperability and acceptance of polymeric insulators across global markets.
- Reducing operational risks by identifying unsuitable insulator designs early through rigorous screening tests.
- Providing a framework for ongoing innovation in polymeric insulator technology aligned with evolving industry needs.
By following the IEC 62217:2012 standard, manufacturers and users of polymeric HV insulators ensure durability, safety, and optimal performance of critical power transmission and distribution infrastructure in demanding applications.
Технические детали
- Технический комитет
- TC 36 - Insulators
- SKU
- IEC 62217:2012
Похожие стандарты
Упомянутые в описании и другие стандарты IEC
IEC 62217:2025
ДействующийPolymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria
Overview IEC 62217:2025 - "Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria" is the international standard that defines common terminolog…
IEC 60507:2013
ДействующийArtificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems
Overview IEC 60507:2013 is an international standard established by the International Electrotechnical Commission (IEC) that defines artificial pollution tests on high-voltage ceramic and glass insul…
IEC 60050-161:1990/AMD2:1998
ДействующийAmendment 2 - International Electrotechnical Vocabulary (IEV) - Part 161: Electromagnetic compatibility
IEC 60050-161:1990/AMD2:1998 – Electromagnetic Compatibility Vocabulary Amendment ### Overview The IEC 60050-161:1990/AMD2:1998 is the second amendment to the International Electrotechnical Vocabular…