IEC 62271-111:2012 PDF
High-voltage switchgear and controlgear - Part 111: Automatic circuit reclosers and fault interrupters for alternating current systems up to 38 kV
High-voltage switchgear and controlgear - Part 111: Automatic circuit reclosers and fault interrupters for alternating current systems up to 38 kV
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 129
- Дата публикации:
- 25 сентября 2012 г.
- Издание:
- IEEE IS 62271 edition 2 version 1
- ICS:
- 29.130.10
IEC 62271-111:2012(E) applies to all overhead, pad mounted, dry vault and submersible single or multi-pole alternating current automatic circuit reclosers and fault interrupters for rated maximum voltages above 1 000 V and up to 38 kV. This second edition cancels and replaces the first edition, published in 2005, and constitutes a technical revision. The main changes with respect to the previous edition are as follows: a) addition of exclusion of devices with dependent manual operation to 1.1; b) harmonization of the amplitude factor kaf used for calculating the TRV for cable connected systems consistent with recent harmonization of the circuit-breaker standards between IEEE and IEC; c) deletion of requirements for radio influence voltage (RIV) tests; d) addition of specifications and ratings to cover the cutout recloser and its special requirements. This standard has been jointly revised by Switchgear Committee of the IEEE Power and Energy Society, in cooperation with subcommittee 17A: High-voltage switchgear and controlgear with reference to IEEE Std C37.60-2012(E). This publication is to be read in conjunction with IEC 62271-1:2007.
Abstract
Overview
IEC 62271-111:2012 is the international standard that specifies requirements, tests and ratings for automatic circuit reclosers (ACRs) and fault interrupters for single- or multi-pole alternating‑current systems with rated maximum voltages above 1 000 V and up to 38 kV. It covers overhead, pad‑mounted, dry‑vault and submersible reclosers and fault interrupters. Edition 2.0 (2012) is a technical revision harmonized with IEEE Std C37.60‑2012 and is intended to be read in conjunction with IEC 62271‑1:2007.
Key Topics and Technical Requirements
- Scope and service conditions: Defines normal and special service conditions (altitude, pollution, temperature, vibration, wind) for indoor and outdoor installations.
- Ratings and characteristics: Requirements for rated voltage, frequency, rated normal current, rated short‑time and peak withstand currents, rated interrupting and making currents, and rated operating sequences.
- Transient Recovery Voltage (TRV): Updated TRV calculation guidance, including harmonization of the amplitude factor (kaf) for cable‑connected systems consistent with IEEE/IEC circuit‑breaker harmonization.
- Design and construction: Enclosure protection (IP/IK), insulation and creepage distances, liquid/gas tightness, tank construction for submersible/dry‑vault units, stored energy and power operation provisions, nameplates and position indication.
- Type tests and routine tests: Dielectric tests, temperature‑rise, short‑time and peak withstand current tests, tightness tests, EMC testing, auxiliary/control circuit tests. Note: radio influence voltage (RIV) test requirements were deleted in this edition.
- Special device types: Addition of specifications and ratings for cutout reclosers and their special requirements.
- Operational mode exclusions: Excludes devices with dependent manual operation (per clause 1.1).
Practical Applications and Who Uses This Standard
IEC 62271‑111 is essential for:
- Utilities and distribution network operators specifying ACRs and fault interrupters for overhead and underground distribution systems.
- Manufacturers and designers developing reclosers, cutout reclosers, and submersible fault interrupters to meet international test and safety benchmarks.
- Test laboratories performing type and routine testing (dielectric, TRV, short‑circuit, EMC).
- Protection and relay engineers, procurement/specification teams, and standards compliance officers ensuring equipment interoperability and safety up to 38 kV.
Typical applications include automated fault isolation and service restoration, rural and urban distribution feeders, pad‑mounted transformer protection, and submarine/submersible installations.
Related Standards
- IEC 62271‑1:2007 - General definitions and common requirements for high‑voltage switchgear and controlgear (to be read together).
- IEEE Std C37.60‑2012 - Harmonized companion standard (joint revision).
Keywords: IEC 62271-111, automatic circuit recloser, fault interrupter, high-voltage switchgear, 38 kV, TRV, IEEE C37.60, type tests, pad-mounted recloser, submersible recloser.
Технические детали
- Технический комитет
- SC 17A - Switching devices
- SKU
- IEC 62271-111:2012
Похожие стандарты
Упомянутые в описании и другие стандарты IEC
IEC 62271-111:2019
ДействующийHigh-voltage switchgear and controlgear - Part 111: Automatic circuit reclosers for alternating current syste…
Overview IEC 62271-111:2019 is the international standard for high-voltage switchgear and controlgear, specifically addressing automatic circuit reclosers for alternating current (AC) systems up to a…
IEC 60050-161:1990/AMD2:1998
ДействующийAmendment 2 - International Electrotechnical Vocabulary (IEV) - Part 161: Electromagnetic compatibility
IEC 60050-161:1990/AMD2:1998 – Electromagnetic Compatibility Vocabulary Amendment ### Overview The IEC 60050-161:1990/AMD2:1998 is the second amendment to the International Electrotechnical Vocabular…