IEC 62493:2015 PDF
Assessment of lighting equipment related to human exposure to electromagnetic fields
Assessment of lighting equipment related to human exposure to electromagnetic fields
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 267
- Дата публикации:
- 15 июня 2022 г.
- Издание:
- IEC IS 62493 edition 2 version 1
- ICS:
- 29.020
IEC 62493:2015 applies to the assessment of lighting equipment related to human exposure to electromagnetic fields. The assessment consists of the induced internal electric field for frequencies from 20 kHz to 10 MHz and the specific absorption rate (SAR) for frequencies from 100 kHz to 300 MHz around lighting equipment. This second edition cancels and replaces the first edition published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) identification of lighting product types deemed to comply with the standard without the need for test; b) deletion of the need for CISPR-15-compliance as a prerequisite for IEC 62493 compliance; c) inclusion of the consequences of the ICNIPR 2010 guidelines for (up to 100 kHz); d) adding some guidance to the Van der Hoofden test head method to improve reproducibility of results; e) inclusion of compliance demonstration method for products having intentional radiators.
Abstract
Overview
IEC 62493:2015 is the International Electrotechnical Commission (IEC) standard dedicated to the assessment of lighting equipment concerning human exposure to electromagnetic fields (EMF). This standard covers critical frequency ranges from 20 kHz to 300 MHz and establishes evaluation methods for the induced internal electric field and the specific absorption rate (SAR) near lighting devices. The 2015 edition of IEC 62493 replaces the previous 2009 version, incorporating significant technical updates to ensure state-of-the-art compliance and safety guidance for manufacturers and regulatory professionals.
Key Topics
-
Human Exposure Assessment IEC 62493 specifies measurement and evaluation techniques for determining the safety of lighting equipment regarding EMF exposure. It focuses on:
- Induced Internal Electric Field: Measured in lighting equipment emissions from 20 kHz to 10 MHz.
- Specific Absorption Rate (SAR): Evaluated for frequencies between 100 kHz and 300 MHz to assess thermal effects on human tissue.
-
Updated Compliance Requirements Notable technical revisions in this edition include:
- Identification of lighting product types that comply without requiring additional testing.
- Removal of the previous prerequisite for compliance with CISPR-15.
- Integration of the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines updated in 2010, specifically relevant to frequencies up to 100 kHz.
- Enhanced guidance on the Van der Hoofden test head measurement method to improve reproducibility and accuracy of results.
- Procedures for demonstrating compliance for lighting equipment featuring intentional radiators (devices emitting radio waves by design).
-
Measurement Techniques The standard outlines the Van der Hoofden test, which uses a specialized head-shaped probe for assessing electric fields induced by lighting equipment. It details setup requirements, ambient conditions for testing, measurement distances, and instrumentation accuracy.
-
Assessment of Intentional Radiators IEC 62493 includes specific procedures for assessing lighting devices that incorporate intentional radio frequency transmitters. This ensures that both unintentional and intentional emissions are adequately evaluated for safety.
Applications
-
Lighting Equipment Manufacturers Utilize IEC 62493 to design, test, and certify lighting products, ensuring compliance with international EMF exposure limits while maintaining product safety and market acceptance.
-
Regulatory Authorities Employ the standard as a benchmark to evaluate lighting products' safety related to electromagnetic field exposure, supporting enforcement of health and safety regulations.
-
Testing Laboratories Apply the standardized measurement methods, including the Van der Hoofden test, to perform consistent and accurate EMF exposure assessments on lighting devices.
-
Product Designers and Engineers Reference this standard during product development to minimize EMF emissions and meet human health safety guidelines effectively.
Related Standards
-
CISPR-15 – Previously linked as a prerequisite, this standard addresses electromagnetic disturbances from lighting equipment but is no longer mandatory for IEC 62493 compliance.
-
ICNIRP Guidelines (2010 & 2020 Revisions) – International guidelines for limiting exposure to non-ionizing radiation; IEC 62493 aligns with these for frequencies up to 100 kHz and integrates updated safety thresholds.
-
IEEE EMF Standards – Complementary guidance on electromagnetic field exposure; some assessment methods and limits referenced in IEC 62493 align with IEEE recommendations.
-
EMF Product Standards for Base Stations and Body-Worn Equipment – Used in assessing radiation from intentional radiators, integrated within the IEC 62493 framework for comprehensive safety evaluation.
Keywords: IEC 62493, electromagnetic fields, lighting equipment safety, human exposure assessment, induced electric field, specific absorption rate, EMF standards, Van der Hoofden test, intentional radiators, ICNIRP guidelines, CISPR-15, lighting EMF compliance.
Технические детали
- Технический комитет
- TC 34 - Lighting
- SKU
- IEC 62493:2015
Похожие стандарты
Другие стандарты IEC
IEC 60050-161:1990/AMD2:1998
ДействующийAmendment 2 - International Electrotechnical Vocabulary (IEV) - Part 161: Electromagnetic compatibility
IEC 60050-161:1990/AMD2:1998 – Electromagnetic Compatibility Vocabulary Amendment ### Overview The IEC 60050-161:1990/AMD2:1998 is the second amendment to the International Electrotechnical Vocabular…