ISO 10282:2023 PDF
Single-use sterile rubber surgical gloves — Specification
Single-use sterile rubber surgical gloves — Specification
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 11
- Дата публикации:
- 16 февраля 2023 г.
- Издание:
- ISO IS 10282 edition 4 version 1
- ICS:
- 11.140
This document specifies requirements for packaged sterile rubber gloves intended for use in surgical procedures to protect the patient and the user from cross-contamination. This document is applicable to single-use gloves that are worn once and then discarded. It does not apply to examination or procedure gloves. This document covers gloves with smooth surfaces and gloves with textured surfaces over part or the whole glove. This document is intended to be a reference for the performance and safety of rubber surgical gloves. The safe and proper usage of surgical gloves and sterilization procedures with subsequent handling, packaging and storage procedures are outside the scope of this document.
Abstract
Overview
ISO 10282:2023 - Single-use sterile rubber surgical gloves - Specification - defines performance and safety requirements for packaged sterile surgical rubber gloves intended for single use in surgical procedures. It covers glove classification by material, design and finish, measurement and sampling rules, mechanical and leakage performance, sterility and biocompatibility expectations, and marking/packaging requirements. (It does not apply to examination/procedure gloves or to use/sterilization/handling procedures.)
Key topics and technical requirements
- Materials & biocompatibility
- Two material types: Type 1 (natural rubber latex) and Type 2 (nitrile, isoprene, polychloroprene, SBR, thermoplastic elastomer solutions).
- Manufacturers must demonstrate compliance with the ISO 10993 biological evaluation series.
- Classification & finishes
- Design: straight or palmar-curved fingers; cuff: cut or rolled rim.
- Finishes: textured, smooth, powdered, and powder-free (powder-free residue limit specified in the standard).
- Dimensions
- Sizes are specified with nominal widths and lengths (e.g., size code 7 = 89 ± 5 mm width, 270 mm minimum length). Single-wall thickness limits differ by finish (smooth vs textured).
- Dimensional measurement method provided in Annex A.
- Watertightness
- Leak testing method is normative (Annex B); sampling and acceptance based on ISO 2859-1 sampling plans with defined AQLs.
- Tensile / mechanical properties
- Tensile testing follows ISO 37 with requirements for force at break, elongation at break, and force at 300% elongation both before and after accelerated ageing (accelerated ageing per ISO 188).
- Example values: minimum elongation before ageing - 700% (Type 1) and 600% (Type 2); minimum force at break before ageing - 12.5 N (Type 1) and 9.0 N (Type 2).
- Sampling & acceptance
- Sampling by ISO 2859-1 with specified inspection levels and AQLs for dimensions, watertightness and tensile properties.
- Packaging & marking
- Requirements for inner/unit/multi-unit package marking and sterility declaration are included.
Applications and users
ISO 10282:2023 is used by:
- Glove manufacturers for product design, production control and compliance.
- Quality and regulatory teams for certification, CE/market access and supplier qualification.
- Testing laboratories for acceptance testing (dimensions, watertightness, tensile, ageing).
- Procurement and clinical engineering to specify supplier and product requirements for sterile single-use surgical gloves.
Related standards
- ISO 37 (tensile testing), ISO 188 (accelerated ageing), ISO 2859-1 (sampling), ISO 10993 (biocompatibility), and ISO 21171 (powder measurement) - all referenced by ISO 10282:2023.
For full test methods, limits and tables, consult ISO 10282:2023 and the referenced normative documents.
Технические детали
- Технический комитет
- ISO/TC 45/SC 4 - Products (other than hoses)
- SKU
- ISO 10282:2023
Похожие стандарты
Стандарты, упомянутые в описании
BS EN ISO 10993-11:2018
ДействующийBiological evaluation of medical devices. Tests for systemic toxicity.
SIST ISO 2859-1:2003/Amd 1:2020
ДействующийSampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality lim…
Overview SIST ISO 2859-1:2003/Amd 1:2020 is an important amendment to the international standard for sampling procedures for inspection by attributes. This standard, titled Part 1: Sampling schemes i…
BS ISO 37108:2022
ДействующийSustainable cities and communities. Business districts. Guidance for practical local implementation of ISO 37…
BS ISO 18828-2:2016
ДействующийIndustrial automation systems and integration. Standardized procedures for production systems engineering. Re…
SIST EN ISO 21171:2006
ДействующийMedical gloves - Determination of removable surface powder (ISO 21171:2006)
Overview EN ISO 21171:2006 - Medical gloves - Determination of removable surface powder (ISO 21171:2006) specifies laboratory test methods to quantify readily removable, water‑insoluble powder on the…