ISO 10349-4:1992 PDF
Photography — Photographic-grade chemicals — Test methods — Part 4: Determination of residue after ignition
Photography — Photographic-grade chemicals — Test methods — Part 4: Determination of residue after ignition
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 2
- Дата публикации:
- 30 декабря 1992 г.
- Издание:
- ISO IS 10349 edition 1 version 1
- ICS:
- 37.040.30
The method is based on weighing a test portion and placing it in prepared ignition crucible, heating the crucible over a low flame to drive off any volatile matter, incineration in a furnace, cooling to room temperature in a desiccator, and reweighing.
Abstract
Overview
ISO 10349-4:1992 - Photography - Photographic-grade chemicals - Test methods - Part 4: Determination of residue after ignition - describes a standardized laboratory procedure to determine the non‑volatile residue (ash) left after ignition of a photographic‑grade chemical. The method is intended for quality control and as a preparative step for subsequent tests (for example, heavy metals and iron). It defines apparatus, sampling references, basic procedure steps, calculation principles and reporting requirements.
Key topics and requirements
- Scope: General test method for determination of residue after ignition for photographic‑grade chemicals.
- Apparatus:
- Ignition crucible: porcelain, alumina, platinum or quartz, capacity ≥ 100 ml.
- Muffle furnace: capable of maintaining temperatures up to 600 °C.
- Desiccator: with suitable desiccant for cooling to room temperature.
- Sampling & references: Sampling is done in accordance with ISO 10349‑1 (General). Hazard guidance and reagent/glassware requirements are also referenced to ISO 10349‑1.
- Procedure (summary):
- Weigh the test portion to the nearest 0.01 g and place it in a prepared ignition crucible.
- Heat over a low flame to drive off volatile matter.
- Incinerate the sample in a muffle furnace for the specified time/temperature.
- Cool to room temperature in a desiccator and reweigh to the required precision (procedure specifies reweighing to 0.001 g where applicable).
- Calculation: Residue is reported as a percentage by mass, based on the masses of the test portion, the empty crucible, and the crucible plus residue after ignition.
- Reporting: The test report must specify the method used, the numerical result, any optional operating details, and any incidents affecting the result, plus full sample identification.
Applications and who uses it
- Quality control laboratories in manufacturers of photographic‑grade chemicals use ISO 10349‑4:1992 to verify purity and consistency.
- Analytical and testing laboratories use the residue after ignition as an input for further analyses (e.g., heavy metals, iron content).
- Procurement and compliance officers rely on standardized test results when specifying or accepting photographic chemicals.
- Research groups working with photographic materials who require reproducible, comparable ash/residue data.
Related standards
- ISO 10349‑1:1992 - Photography - Photographic‑grade chemicals - Test methods - Part 1: General (sampling, hazards, reagents, and notation for drying).
- Other parts of ISO 10349 series cover insoluble matter, heavy metals, halides, alkalinity, volatile matter, sulfide content, specific gravity, density, and related test methods.
Keywords: ISO 10349-4:1992, residue after ignition, photographic-grade chemicals, ignition crucible, muffle furnace, desiccator, test method, photography quality control.
Технические детали
- Технический комитет
- ISO/TC 42 - Photography
- SKU
- ISO 10349-4:1992
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
ISO 10349-1:1992
ОтменёнPhotography — Photographic-grade chemicals — Test methods — Part 1: General
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…
ISO/ASTMTR52917-EB
ДействующийAdditive Manufacturing — Round Robin Testing — General Guidelines
This document outlines the steps with regard to aspects of design to conduct and run a round robin study (RRS) to assess the degree of variability in an additive manufacturing material or process. Th…