ISO 10498:2004 PDF
Ambient air — Determination of sulfur dioxide — Ultraviolet fluorescence method
Ambient air — Determination of sulfur dioxide — Ultraviolet fluorescence method
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 10
- Дата публикации:
- 11 июня 2004 г.
- Издание:
- ISO IS 10498 edition 1 version 1
- ICS:
- 13.040.20
ISO 10498:2004 describes an ultraviolet fluorescence method for sampling and determining sulfur dioxide (SO2) concentrations in the ambient air using automatic analysers. ISO 10498:2004 is applicable to the determination of sulfur dioxide mass concentrations of a few micrograms per cubic metre to a few milligrams per cubic metre or, expressed in terms of volume fraction, from a few microlitres per cubic metre to a few millilitres per cubic metre.
Abstract
Overview
ISO 10498:2004 - Ambient air: Determination of sulfur dioxide (SO2) by ultraviolet fluorescence specifies an automatic-analyser method for sampling and measuring SO2 in ambient air. The standard covers measurement ranges from a few micrograms per cubic metre up to a few milligrams per cubic metre (or, in volume terms, from µL/m3 to mL/m3). It defines the measurement principle, calibration requirements, sampling and instrument components, and routine quality-control procedures to ensure accurate, traceable SO2 measurements.
Key topics and technical requirements
- Measurement principle: Ultraviolet fluorescence - SO2 is excited by UV (≈200–220 nm) and emits fluorescence (≈240–420 nm); intensity is proportional to SO2 concentration.
- Instrumentation: Components include UV lamp (stabilized supply), reaction chamber, optical filters, photomultiplier detector, modulator, selective traps for interferents, flow controller, pressure regulator and pump.
- Calibration: Instruments are not absolute - regular calibration against primary calibration gas standards is required. Calibration protocol includes zero air, span gas and at least five calibration points across the measurement range. Calibration gas flow to the manifold should exceed instrument demand by ≥20%.
- Zero air and calibration gases: Zero air must contain no detectable SO2 and have O2 within ±2% of normal air (20.9%). Primary calibration methods referenced include static volumetric dilution, permeation tubes, TCM method and gravimetric gas preparation.
- Interferences and controls: Potential interferents: hydrogen sulfide (H2S), aromatic hydrocarbons, nitric oxide (NO), water vapor and low-molecular-weight mercaptans. Selective traps/scrubbers and optical filtering are required; temperature and pressure compensation or correction is necessary.
- Sampling line and materials: Use chemically inert materials (e.g., fluorocarbon polymer or glass). Minimize residence time; heat lines or cell above dewpoint to prevent condensation. Particulate inlet filters should be inert and not retain SO2.
- Quality assurance & maintenance: Routine zero/span checks (preferably daily, at least weekly), regular servicing (recommended semi‑annually or annually) and comparison of transfer standards with primary standards.
Applications and users
ISO 10498:2004 is used for:
- Regulatory ambient-air monitoring and compliance reporting
- Continuous urban/regional air quality networks and meteorological stations
- Environmental laboratories and reference measurement facilities
- Instrument manufacturers, calibration laboratories and field-service technicians
- Research applications requiring traceable SO2 time-series or concentration maps
Using ISO 10498 ensures consistency, comparability and traceability of SO2 data for health impact assessments, emissions control, air quality management and regulatory enforcement.
Related standards
Standards referenced by ISO 10498:2004 include:
- ISO 4219 (sampling equipment)
- ISO 6142, ISO 6144, ISO 6145 (calibration gas preparation methods)
- ISO 6349 (permeation method)
- ISO 6767 (TCM/pararosaniline SO2 method)
- ISO 9169 (performance characteristics of automatic measuring systems)
- ISO 6879 (operational quality control examples)
These related standards support calibration, sampling best practice and performance verification for traceable SO2 measurement.
Технические детали
- Технический комитет
- ISO/TC 146/SC 3 - Ambient atmospheres
- SKU
- ISO 10498:2004
Похожие стандарты
Стандарты, упомянутые в описании
SIST ISO 10498:2004
ДействующийAmbient air -- Determination of sulfur dioxide -- Ultraviolet fluorescence method
Overview ISO 10498:2004 - Ambient air: Determination of sulfur dioxide (SO2) by ultraviolet fluorescence specifies an automatic-analyser method for sampling and measuring SO2 in ambient air. The stan…
SIST ISO 4219:1995
ДействующийAir quality - Determination of gaseous sulphur compounds in ambient air - Sampling equipment
Overview SIST ISO 4219:1995 is an international standard developed by the International Organization for Standardization (ISO) that specifies the general requirements for sampling equipment used to d…
ISO 6142-1:2015/Amd 1:2020
ДействующийGas analysis — Preparation of calibration gas mixtures — Part 1: Gravimetric method for Class I mixtures — Am…
Overview ISO 6142-1:2015/Amd 1:2020 is an important amendment to the international standard governing the preparation of calibration gas mixtures through the gravimetric method for Class I mixtures.…
SIST EN ISO 6144:2006
ДействующийGas analysis - Preparation of calibration gas mixtures - Static volumetric method (ISO 6144:2003)
Overview EN ISO 6144:2006 (identical to ISO 6144:2003) defines a static volumetric method for preparing calibration gas mixtures used in gas analysis. The standard specifies how to prepare binary or…
SIST EN ISO 6145-1:2019
ДействующийGas analysis - Preparation of calibration gas mixtures using dynamic methods - Part 1: General aspects (ISO 6…
Overview EN ISO 6145-1:2019 - "Gas analysis - Preparation of calibration gas mixtures using dynamic methods - Part 1: General aspects" provides a consolidated, practical introduction to the dynamic t…
ISO 6349:1979
ОтменёнGas analysis — Preparation of calibration gas mixtures — Permeation method
SIST ISO 6767:1996
ДействующийAmbient air - Determination of the mass concentration of sulfur dioxide - Tetrachloromercurate (TCM)/pararosa…
Overview - ISO 6767:1990 (Ambient air - SO2, TCM/pararosaniline method) ISO 6767:1990 specifies a spectrophotometric procedure (the tetrachloromercurate / pararosaniline or TCM/pararosaniline method)…
SIST EN ISO 9169:2007
ДействующийAir quality - Definition and determination of performance characteristics of an automatic measuring system (I…
Overview EN ISO 9169:2006 (ISO 9169:2006) defines and specifies methods to determine the performance characteristics of an identified automatic air quality measuring system (AMS). The standard treats…