ISO 10893-11:2011 PDF
Non-destructive testing of steel tubes — Part 11: Automated ultrasonic testing of the weld seam of welded steel tubes for the detection of longitudinal and/or transverse imperfections
Non-destructive testing of steel tubes — Part 11: Automated ultrasonic testing of the weld seam of welded steel tubes for the detection of longitudinal and/or transverse imperfections
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 9
- Дата публикации:
- 24 марта 2011 г.
- Издание:
- ISO IS 10893 edition 1 version 1
- ICS:
- 23.040.10
ISO 10893-11:2011 specifies requirements for the automated ultrasonic shear wave (generated by conventional or phased array technique) testing of the weld seam of submerged arc-welded (SAW) or electric resistance and induction-welded (EW) steel tubes. For SAW tubes, the test covers the detection of imperfections oriented predominantly parallel to or, by agreement, perpendicular to the weld seam or both. For EW tubes, the test covers the detection of imperfections oriented predominantly parallel to the weld seam. In the case of testing on longitudinal imperfections, Lamb wave testing can be applied at the discretion of the manufacturer. ISO 10893-11:2011 can also be applicable to the testing of circular hollow sections.
Abstract
Overview
ISO 10893-11:2011 specifies requirements for automated ultrasonic testing (AUT) of the weld seam of welded steel tubes to detect longitudinal and/or transverse imperfections. It covers shear-wave techniques (conventional or phased array) for submerged arc-welded (SAW) and electric resistance/induction-welded (EW) tubes, and permits Lamb wave testing for longitudinal defects where agreed. The standard is also applicable to circular hollow sections and supports inline or post-process inspection of tube welds.
Key topics and technical requirements
- Scope: AUT of SAW and EW tube weld seams for longitudinal/transverse imperfections; full peripheral UT possible for EW tubes.
- Inspection techniques: Shear-wave ultrasonic (1–15 MHz) and Lamb wave (0.3–1 MHz) where permitted. Supports conventional and phased array transducers.
- Probe and aperture limits: Maximum individual transducer width 25 mm for longitudinal or transverse detection; phased array / Lamb active aperture limited to 35 mm.
- Scan directions & coverage: Testing normally in two opposite directions (clockwise/anticlockwise for longitudinal; forward/backward for transverse). Test movement speed must not vary by more than ±10%. Complete weld coverage required; short untested tube ends handled per product standard or Annex A.
- Calibration & reference: Use reference tubes with notches or reference holes (internal/external) placed close to the weld to set sensitivity and trigger levels. Reference tube must match nominal diameter, thickness, surface finish and acoustic properties of production tubes.
- Equipment performance: Automated trigger/alarm classification combined with marking or sorting. Calibration checks and periodic recalibration required.
- Personnel: Operators must be qualified per ISO 9712, ISO 11484 or equivalent; NDT authorization and level 3 oversight required.
Applications and users
ISO 10893-11 is used by:
- Tube manufacturers (SAW, EW) integrating automated weld seam inspection into production lines
- Quality/control engineers and NDT technicians performing routine acceptance testing
- Third‑party inspectors and regulatory bodies verifying weld seam integrity
- Industries using welded steel tubes (petrochemical, structural, mechanical, pipeline, automotive) requiring reliable detection of longitudinal and transverse weld defects
Practical benefits include improved defect detection, traceable calibration and acceptance procedures, automated sorting/marking, and compatibility with inline production workflows.
Related standards
- ISO 10893-10 (full peripheral ultrasonic testing)
- ISO 10893-6 / ISO 10893-7 (radiographic and digital radiographic testing of weld seams)
- ISO 5577 (ultrasonic NDT vocabulary)
- ISO 9712 / ISO 11484 (personnel qualification)
Keywords: ISO 10893-11, ultrasonic testing, weld seam, steel tubes, SAW, EW, phased array, Lamb wave, non-destructive testing, AUT, NDT calibration.
Технические детали
- Технический комитет
- ISO/TC 17/SC 19 - Technical delivery conditions for steel tubes for pressure purposes
- SKU
- ISO 10893-11:2011
Похожие стандарты
Стандарты, упомянутые в описании
SIST EN ISO 9712:2022
ДействующийNon-destructive testing - Qualification and certification of NDT personnel (ISO 9712:2022)
Overview EN ISO 9712:2022 - Non-destructive testing (NDT) - Qualification and certification of NDT personnel (ISO 9712:2021) is a CEN-adopted international standard that defines requirements for cert…
BS ISO 11484:2019
ДействующийSteel products. Employer´s qualification system for non-destructive testing (NDT) personnel.
ISO 10893-11:2011/Amd 1:2020
ДействующийNon-destructive testing of steel tubes — Part 11: Automated ultrasonic testing of the weld seam of welded ste…
Overview ISO 10893-11:2011/Amd 1:2020 is an amendment to the International Standard focused on the non-destructive testing (NDT) of welded steel tubes. Primarily, it addresses the automated ultrasoni…
ISO 10893-10:2011/Amd 1:2020
ДействующийNon-destructive testing of steel tubes — Part 10: Automated full peripheral ultrasonic testing of seamless an…
Overview ISO 10893-10:2011/Amd 1:2020 is an amendment to the internationally recognized ISO 10893-10 standard. It addresses automated full peripheral ultrasonic testing of seamless and welded (except…
BS EN ISO 10893-6:2019
ДействующийNon-destructive testing of steel tubes. Radiographic testing of the weld seam of welded steel tubes for the d…
BS EN ISO 10893-7:2019
ДействующийNon-destructive testing of steel tubes. Digital radiographic testing of the weld seam of welded steel tubes f…
SIST EN ISO 5577:2026
ДействующийNon-destructive testing - Ultrasonic testing - Vocabulary (ISO 5577:2025)
Overview EN ISO 5577:2025 - Non-destructive testing - Ultrasonic testing - Vocabulary is the ISO/CEN vocabulary standard that defines the terms used in ultrasonic non‑destructive testing (NDT). Publi…