ISO 11132:2021 PDF
Sensory analysis — Methodology — Guidelines for the measurement of the performance of a quantitative descriptive sensory panel
Sensory analysis — Methodology — Guidelines for the measurement of the performance of a quantitative descriptive sensory panel
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 22
- Дата публикации:
- 8 сентября 2021 г.
- Издание:
- ISO IS 11132 edition 2 version 1
- ICS:
- 67.240
This document gives guidelines for assessing the overall performance of a quantitative descriptive panel and the performance of each panel member. This document is applicable to the validation of the training of individual assessors or panels, as well as to the performance monitoring of established panels. This document does not apply to the panel performance for descriptive methods where the individual scores of each assessor are not recorded, where there is no single list of attributes that is common to all the assessors, or where dominance rather than intensity is measured. Consequently, the performance of descriptive panels using methods such as consensus profile, free-choice profile, flash profile and temporal dominance of sensations (TDS) are out of scope. The methods specified in this document are for monitoring and assessing the ability of a panel and its assessors to discriminate between products, the agreement between assessors of the same panel and the repeatability of these assessors in their intensity scoring. Reproducibility, including both the comparison between panels and the comparison within the same panel of several evaluations conducted under different conditions (i.e. separated in time), is out of scope of this document. The methods specified in this document can be used, in full or a selection only, by the panel leader to appraise continuously the performance of panels or individual assessors. The methods listed are not exhaustive and other appropriate methods can also be used.
Abstract
Overview
ISO 11132:2021 - Sensory analysis: Guidelines for measuring the performance of a quantitative descriptive sensory panel provides practical guidance for validating and monitoring the performance of descriptive sensory panels and individual assessors. The standard focuses on assessing a panel’s ability to discriminate between products, the agreement between assessors, and the repeatability of intensity scoring. It is applicable to quantitative descriptive panels where individual assessor scores and a common attribute list are recorded. Methods for consensus or dominance-based approaches (e.g., free-choice profile, flash profile, temporal dominance of sensations) and inter‑panel reproducibility are out of scope.
Key Topics and Requirements
- Scope and applicability
- Validation of assessor training and ongoing performance monitoring of established panels.
- Excludes methods where individual scores are not recorded and excludes reproducibility across different conditions.
- Two measurement approaches
- Dedicated performance procedures: structured experiments designed to evaluate discrimination, repeatability and agreement.
- Ongoing monitoring via routine product profiling: use of routine profiling data to track panel performance over time.
- Experimental design requirements
- Guidance on sample and attribute selection and on designs such as randomized block, balanced/random designs and same-order designs.
- Statistical analyses
- Emphasis on analysis of variance (ANOVA) models, including consideration of session and panellist effects (fixed or random) and interactions.
- Interpretation guidance for panel-level and individual assessor outputs: discrimination, agreement, repeatability, consistency, and bias (including panel drift).
- Prerequisites
- Defined experimental conditions and qualification criteria for assessors before performance measurement.
Applications
- Continuous panel performance monitoring in sensory laboratories.
- Validation of training programs for new assessors in food and beverage sensory evaluation.
- Quality assurance for product profiling used in product development, reformulation, and sensory quality control.
- Identification of retraining needs, assessor bias or panel drift and support for corrective actions.
Who should use this standard
- Panel leaders and sensory laboratory managers
- Sensory scientists and researchers
- Quality assurance professionals in food, beverage and consumer products industries
Related standards
- ISO 5492 (Sensory analysis - Vocabulary) is referenced normatively for terms and definitions used in ISO 11132:2021.
Keywords: ISO 11132, sensory analysis, quantitative descriptive analysis, sensory panel performance, panel validation, panel monitoring, repeatability, discrimination, agreement, ANOVA.
Технические детали
- Технический комитет
- ISO/TC 34/SC 12 - Sensory analysis
- SKU
- ISO 11132:2021
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
ISO 5492:2008/Amd 1:2016
ДействующийSensory analysis — Vocabulary — Amendment 1
Overview ISO 5492:2008/Amd 1:2016 is an amendment to ISO 5492:2008 - the international vocabulary for sensory analysis. Rather than prescribing procedures, this amendment expands and clarifies termin…
SIST EN ISO 11132:2021
ДействующийSensory analysis - Methodology - Guidelines for the measurement of the performance of a quantitative descript…
Overview EN ISO 11132:2021 - Sensory analysis - Methodology - Guidelines for the measurement of the performance of a quantitative descriptive sensory panel (ISO 11132:2021) provides guidance for asse…
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…