ISO 11357-6:2018 PDF
Plastics — Differential scanning calorimetry (DSC) — Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT)
Plastics — Differential scanning calorimetry (DSC) — Part 6: Determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT)
- Статус документа:
- Отменён
- Формат:
- Электронный (PDF)
- Количество страниц:
- 12
- Дата публикации:
- 9 марта 2018 г.
- Издание:
- ISO IS 11357 edition 3 version 1
- ICS:
- 83.080.01
ISO 11357-6:2018 specifies methods for the determination of oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT) of polymeric materials by means of differential scanning calorimetry (DSC). It is applicable to polyolefin resins that are in a fully stabilized or compounded form, either as raw materials or finished products. It can be applicable to other plastics.
Abstract
Overview
ISO 11357-6:2018 specifies DSC (differential scanning calorimetry) methods for measuring oxidation induction time (isothermal OIT) and oxidation induction temperature (dynamic OIT) of polymeric materials. The standard is primarily applicable to polyolefin resins-in fully stabilized or compounded form, as raw materials or finished products-but can be applied to other plastics. Tests detect the onset of exothermic oxidation by DSC to assess a material’s resistance to oxidative decomposition and the effectiveness of antioxidant systems.
Key keywords: ISO 11357-6, DSC, differential scanning calorimetry, oxidation induction time, OIT, isothermal OIT, dynamic OIT, oxidation induction temperature, polyolefin, plastics testing.
Key Topics
- Principle:
- Isothermal OIT: specimen is heated in an inert atmosphere (nitrogen) to the test temperature, then the atmosphere is switched to oxygen/air and the time to oxidation onset is recorded.
- Dynamic OIT: specimen is heated in oxygen/air at a constant heating rate; the temperature at oxidation onset is recorded.
- Test instrumentation and materials:
- DSC capable of ≥ 500 °C, with isothermal stability of ±0.3 K typical; ±0.1 K recommended for high precision.
- Use open or ventilated crucibles (aluminium preferred); crucible material can significantly influence results.
- Gas control: nitrogen, oxygen and air flows, flowmeter and gas-selector switch are required for OIT tests.
- Specimen preparation and conditioning: relevant methods for moulded/injection specimens and finished parts are referenced (e.g., ISO 293, ISO 294‑3).
- Calibration, procedure and data expression: clauses cover setting up the instrument, loading crucibles, gas flows, sensitivity adjustment, onset-detection and reporting.
- Interpretation cautions: OIT/OOT are relative measures of stabilization - they indicate antioxidant effectiveness but do not provide antioxidant concentration. Pure oxygen tests produce lower OIT/OOT than atmospheric-air tests. Surface area, temperature and heating rate affect results.
Applications
- Quality control and acceptance testing of polyolefin resins, masterbatches and finished plastic parts.
- R&D for formulation optimization and antioxidant selection.
- Failure analysis where oxidative degradation is suspected.
- Material specifications and supplier qualification in plastics manufacturing and converting. Users: polymer testing labs, formulation scientists, quality engineers, converters, certification bodies.
Related standards
- ISO 11357-1 (DSC general principles)
- ISO 293, ISO 294‑3, ISO 8986‑2, ISO 19069‑2 (specimen preparation and related plastics test methods)
- Other parts of the ISO 11357 series covering thermal analysis
This standard provides a reproducible DSC procedure for assessing oxidative stability (OIT/OOT) and is essential for labs performing thermal analysis of plastics.
Технические детали
- Технический комитет
- ISO/TC 61/SC 5 - Physical-chemical properties
- SKU
- ISO 11357-6:2018
Похожие стандарты
Стандарты, упомянутые в описании
SIST EN ISO 11357-6:2025
ДействующийPlastics - Differential scanning calorimetry (DSC) - Part 6: Determination of oxidation induction time (isoth…
Overview EN ISO 11357-6:2025 - Plastics - Differential scanning calorimetry (DSC) - Part 6 specifies standardized methods to determine oxidation resistance of polymeric materials using DSC. It covers…
SIST EN ISO 293:2023
ДействующийPlastics - Compression moulding of test specimens of thermoplastic materials (ISO 293:2023)
Overview EN ISO 293:2023 - Plastics: Compression moulding of test specimens of thermoplastic materials (ISO 293:2023) specifies general principles and procedures for preparing compression‑moulded tes…
SIST EN ISO 294-3:2020
ДействующийPlastics - Injection moulding of test specimens of thermoplastic materials - Part 3: Small plates (ISO 294-3:…
Overview EN ISO 294-3:2020 - Plastics - Injection moulding of test specimens of thermoplastic materials - Part 3: Small plates - specifies the design and use of two two-cavity ISO moulds (type D11 an…
BS EN ISO 11357-1:2023
ДействующийPlastics. Differential scanning calorimetry (DSC). General principles.
ISO 8986-2:1995/Amd 1:2000
ОтменёнPlastics — Polybutene (PB) moulding and extrusion materials — Part 2: Preparation of test specimens and deter…
SIST EN ISO 19069-2:2025
ДействующийPlastics - Polypropylene (PP) moulding and extrusion materials - Part2: Preparation of test specimens and det…
Overview EN ISO 19069-2:2024 (ISO 19069-2:2024) defines standardized procedures for the preparation of test specimens and the determination of properties of polypropylene (PP) moulding and extrusion…