ISO 12500-1:2007 PDF
Filters for compressed air — Test methods — Part 1: Oil aerosols
Filters for compressed air — Test methods — Part 1: Oil aerosols
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 9
- Дата публикации:
- 4 июня 2007 г.
- Издание:
- ISO IS 12500 edition 1 version 1
- ICS:
- 23.100.60
ISO 12500-1:2007 specifies the test layout and test procedures required for testing coalescing filters used in compressed-air systems to determine their effectiveness in removing oil aerosols. ISO 12500-1:2007 provides the means to indicate performance characteristics of the pressure drop and the capability of removing oil aerosols. ISO 12500-1:2007 defines one method of presenting filter performance as outlet oil aerosol concentration stated in milligrams per cubic metre from results obtained under standard rating parameters.
Abstract
Overview
ISO 12500-1:2007 - "Filters for compressed air - Test methods - Part 1: Oil aerosols" specifies the test layout and procedures for evaluating coalescing filters used in compressed-air systems. The standard defines how to measure a filter’s ability to remove oil aerosols and the associated pressure drop, and presents one method of reporting filter performance as outlet oil aerosol concentration (mg/m³) under defined rating parameters.
Key topics and technical requirements
- Test layout and equipment: Typical test rig arrangement (air supply, aerosol generator, flow control, sensing points, filter under test) and sampling points are defined.
- Standard rating parameters: Reference conditions include inlet temperature (~20 °C), test pressure (commonly 700 kPa / 7 bar(e)), rated flow (100% of manufacturer’s rated flow) and inlet oil-aerosol challenge concentration (documented test values).
- Aerosol challenge: Poly-disperse oil aerosol with mean particle size ~0.15–0.40 µm (by particle count). Care to ensure aerosols, not wall flow, enter the filter.
- Flow and Reynolds number: Tests use the manufacturer’s maximum rated continuous flow; minimum Reynolds number in the inlet pipe shall be 4 000 to maintain turbulent flow.
- Conditioning and wet pressure drop: Filters must reach equilibrium (liquid oil visible in housing and pressure-drop change