ISO 12609-2:2013 PDF
Eyewear for protection against intense light sources used on humans and animals for cosmetic and medical applications — Part 2: Guidance for use
Eyewear for protection against intense light sources used on humans and animals for cosmetic and medical applications — Part 2: Guidance for use
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 18
- Дата публикации:
- 22 июля 2013 г.
- Издание:
- ISO IS 12609 edition 1 version 1
- ICS:
- 13.340.20
ISO 12609-2:2013 gives guidance and information to users, manufacturers, suppliers, and safety advisors on the selection and use of eye protectors for intense light source (ILS) equipment used on humans and animals for cosmetic and medical applications against excessive exposure to optical radiation in the spectral range 250 nm to 3 000 nm, with the exception of laser radiation. ISO 12609-2:2013 provides guidance on selection of an eye protector expected to cope with the majority of applications and a more rigorous procedure for determining appropriate eye protection against spectral outputs from ILS equipment.
Abstract
Overview - ISO 12609-2:2013 (Guidance for use)
ISO 12609-2:2013 provides practical guidance on the selection and use of protective eyewear for Intense Light Source (ILS) equipment used on humans and animals in cosmetic and medical applications. It covers protection against excessive optical radiation in the spectral range 250 nm to 3 000 nm (excluding laser radiation). The standard helps users, manufacturers, suppliers and safety advisors perform risk assessments, choose appropriate eye protectors, and apply control measures to prevent ocular and skin over‑exposure.
Key topics and technical requirements
- Scope and terms: Defines ILS, exposure limit values (ELVs), ocular hazard distance (OHD), pulse duration, and skin hazard distance.
- Risk assessment: Compare predicted or measured exposure with ELVs to determine need for eye protection; includes procedures for retinal thermal hazard assessment (Annex B) and worked examples (Annex C).
- Hierarchy of controls: Prioritizes engineering and administrative controls (containment, enclosures, interlocks, training) before personal protective equipment (PPE).
- Protective eyewear guidance:
- Selection criteria for patient/client and operator eyewear (checklists in Annex D and E).
- Recommended evaluation distance of 200 mm from the ILS for determining filter performance.
- Avoid reliance on optical density/shade numbers; use Filter Protection Factor (FPF) - the spectrally weighted attenuation required to ensure exposures do not exceed ELVs (Annex F).
- Visual performance: Luminous transmittance and colour perception through filters affect treatment and safety; colour coordinates (CIE x,y) and guidance are provided (Annex G, H).
- User comfort and secondary safety:
- Prevent peripheral leakage, test fit with bright light prior to use.
- Avoid mirror-finish frames/filters to reduce secondary reflections.
- Limit eyewear temperature rise to ≤ 5 °C during treatment to prevent thermal injury.
- Consider auto‑darkening filters for protection against bright flashes and transient visual impairment; account for filter response time.
Practical applications and users
ISO 12609-2 is intended for:
- Medical device manufacturers and ILS equipment designers (to specify safe eyewear interfaces).
- Clinic managers, safety officers, dermatologists, cosmetic practitioners and veterinary professionals (for risk assessment and PPE selection).
- Suppliers of protective eyewear and safety advisors evaluating operator vs patient protection needs. Typical use cases include intense pulsed light (IPL) treatment, photo-rejuvenation, and other non‑laser optical therapies where ocular exposure risks must be managed.
Related standards and guidance
- ISO 12609-1 - Specification for products (complements Part 2 by defining eyewear product requirements).
- ICNIRP guidelines referenced for Exposure Limit Values (ELVs).
- Use together with device‑specific safety standards and local regulatory requirements.
Keywords: ISO 12609-2, eyewear protection, intense light sources, optical radiation, filter protection factor, FPF, exposure limit values, ELVs, risk assessment, medical cosmetic safety.
Технические детали
- Технический комитет
- ISO/TC 94/SC 6 - Eye and face protection
- SKU
- ISO 12609-2:2013
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
SIST EN ISO 12609-1:2025
ДействующийEye and face protection against intense light sources used on humans and animals for cosmetic and medical app…
Overview EN ISO 12609-1:2025 - Eye and face protection against intense light sources used on humans and animals for cosmetic and medical applications (Part 1: Specification for products) specifies pr…
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…
ISO/ASTMTR52917-EB
ДействующийAdditive Manufacturing — Round Robin Testing — General Guidelines
This document outlines the steps with regard to aspects of design to conduct and run a round robin study (RRS) to assess the degree of variability in an additive manufacturing material or process. Th…