ISO 12828-1:2011 PDF
Validation method for fire gas analysis — Part 1: Limits of detection and quantification
Validation method for fire gas analysis — Part 1: Limits of detection and quantification
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 20
- Дата публикации:
- 23 ноября 2011 г.
- Издание:
- ISO IS 12828 edition 1 version 1
- ICS:
- 13.220.01
In ISO 12828-1:2007, limits of detection and limits of quantification are defined and calculated. It provides methods for determining suitable values for these two parameters for a specific analytical procedure and for a specific chemical species. It does not provide detailed guidance on methods of sampling and analysis of specific species which might be present in fire effluents. This guidance is contained in ISO 19701 and ISO 19702.
Abstract
Overview
ISO 12828-1:2011 - Validation method for fire gas analysis, Part 1: Limits of detection and quantification - provides standardized guidance for defining and determining limits of detection (LOD) and limits of quantification (LOQ) for analytical methods used on fire effluents. It focuses on how to calculate suitable LOD and LOQ values for a specific analytical procedure and chemical species, helping laboratories and practitioners validate measurement methods without prescribing sampling techniques or species-specific analysis (see ISO 19701 / ISO 19702 for those details).
Key topics
- Definitions and terms: Clear definitions for LOD and LOQ and associated notation, aligned with ISO vocabularies and measurement standards.
- Risk concepts: Discussion of false positives (α risk) and false negatives (β risk) and why minimizing false negatives is critical in fire safety.
- Practical criteria: Typical conventions-LOQ often taken as ~10 × standard deviation of blank; LOD often ~3 × standard deviation of blank (and LOQ ≈ 50% of repeatability in some contexts).
- Validation methods: Three main approaches are described:
- Main method 1 - determination from blank/matrix data
- Main method 2 - determination from calibration linearity
- Main method 3 - checking a prescribed quantification limit
- Plus other secondary/alternative methods and examples
- Validation workflow: Four-step process - define end-use, set required sensitivity/precision, select sampling and analytical method, then evaluate LOD/LOQ and uncertainty.
- Reporting: Minimum requirements for presenting LOD/LOQ and how to express results near these limits to support reproducibility and inter-laboratory comparisons.
Applications and users
ISO 12828-1 is designed for:
- Testing and calibration laboratories performing chemical analysis of fire effluents (helps meet ISO/IEC 17025 competence requirements).
- Fire safety engineers using quantitative effluent data for toxicity indices or fractional effective dose (ISO 13571) and time-to-escape calculations.
- Analytical chemists and QA managers who validate FTIR or other gas-analysis methods for smoke and toxicants.
- Regulators and standard developers assessing method suitability, comparing methods in round-robin tests, or setting minimum LOQ for toxicity-based classifications.
Practical uses include method validation, setting quantification limits consistent with toxicological thresholds, ensuring comparability in inter-lab studies, and reliable reporting of low-level measurements in fire testing.
Related standards
- ISO 19701 - Methods for sampling and analysis of fire effluents
- ISO 19702 - Guidance for analysis of gases and vapours in fire effluents (FTIR)
- ISO/IEC 17025 - Competence of testing and calibration laboratories
- ISO 13571, ISO 13943, ISO 5725-1 - supporting guidance on toxicity, vocabulary and measurement accuracy
Keywords: ISO 12828-1:2011, LOD, LOQ, limits of detection, limits of quantification, fire gas analysis, validation method, fire effluents, ISO/IEC 17025, fire safety.
Технические детали
- Технический комитет
- ISO/TC 92/SC 3 - Fire threat to people and environment
- SKU
- ISO 12828-1:2011
Похожие стандарты
Стандарты, упомянутые в описании
SIST ISO 19701:2018
ДействующийMethods for sampling and analysis of fire effluents
Overview SIST ISO 19701:2018 (identical to ISO 19701:2013) specifies methods for sampling and chemical analysis of fire effluents - the gases produced by combustion in fire tests. The standard focuse…
ISO 19702:2006
ОтменёнToxicity testing of fire effluents — Guidance for analysis of gases and vapours in fire effluents using FTIR…
ISO 6141:2015/Amd 1:2020
ДействующийGas analysis — Contents of certificates for calibration gas mixtures — Amendment 1: Cross reference list to I…
Overview ISO 6141:2015/Amd 1:2020 is an important amendment to the international standard ISO 6141:2015, which specifies the contents of certificates for calibration gas mixtures used in gas analysis…
ISO 13571:2007
ОтменёнLife-threatening components of fire — Guidelines for the estimation of time available for escape using fire d…
SIST EN ISO 13943:2024
ДействующийFire safety - Vocabulary (ISO 13943:2023)
Overview SIST EN ISO 13943:2024 is the Slovenian adoption of EN ISO 13943:2023 / ISO 13943:2023, the international vocabulary for fire safety. This fourth edition updates and expands the standardized…
SIST ISO 5725-1:2024
ДействующийAccuracy (trueness and precision) of measurement methods and results - Part 1: General principles and definit…
Overview SIST ISO 5725-1:2024, "Accuracy (trueness and precision) of measurement methods and results - Part 1: General principles and definitions," is published by the International Organization for…