ISO 13232-3:2005 PDF
Motorcycles — Test and analysis procedures for research evaluation of rider crash protective devices fitted to motorcycles — Part 3: Motorcyclist anthropometric impact dummy
Motorcycles — Test and analysis procedures for research evaluation of rider crash protective devices fitted to motorcycles — Part 3: Motorcyclist anthropometric impact dummy
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 88
- Дата публикации:
- 8 декабря 2005 г.
- Издание:
- ISO IS 13232 edition 2 version 1
- ICS:
- 43.140
ISO 13232-3:2005 specifies the minimum requirements for the: biofidelity of the motorcyclist anthropometric impact dummy; compatibility of the dummy with motorcycles, helmets, multi-directional impacts, and the instrumentation; and repeatability and reproducibility of the dummy properties and responses. ISO 13232 specifies minimum requirements for research into the feasibility of protective devices fitted to motorcycles, which are intended to protect the rider in the event of a collision. ISO 13232 is applicable to impact tests involving: two-wheeled motorcycles; the specified type of opposing vehicle; either a stationary and a moving vehicle or two moving vehicles; for any moving vehicle, a steady speed and straight-line motion immediately prior to impact; one helmeted dummy in a normal seating position on an upright motorcycle; the measurement of the potential for specified types of injury, by body region; and evaluation of the results of paired impact tests (i.e. comparisons between motorcycles fitted and not fitted with the proposed devices). ISO 13232 does not apply to testing for regulatory or legislative purposes.
Abstract
Overview
ISO 13232-3:2005 defines the minimum requirements for a motorcyclist anthropometric impact dummy used in research evaluation of rider crash protective devices fitted to motorcycles. The standard focuses on dummy biofidelity, compatibility with motorcycles/helmets/multi‑directional impacts and instrumentation, plus repeatability and reproducibility of dummy properties and responses. ISO 13232-3 is part of the ISO 13232 series for research into motorcycle protective devices and is explicitly for research use only - not for regulatory or legislative testing.
Key topics and technical requirements
- Mechanical requirements for the full dummy and major subsystems: head and head skins, neck, upper/lower torso, arms, hands, upper/lower legs and frangible knee assemblies.
- Frangible components (bones, knee, tibia/femur interfaces): sampling, initial and subsequent conformity, static and dynamic tests (bending, torsion, axial fracture) and certification criteria.
- Neck testing: dynamic and static test procedures and corridors to validate neck biofidelity under extension, flexion, lateral and torsional loading.
- Instrumentation and interfaces: compatibility of sensors and transducers (e.g., lumbar spine load cells), mounts and dummy-to-motorcycle interfaces to capture injury metrics by body region.
- Repeatability and reproducibility: procedures and acceptance criteria to ensure consistent dummy performance across production batches and test sessions.
- Marking and documentation: required identification and certification records for frangible parts and complete dummy assemblies.
- Annexes and drawings: normative drawings for special components and informative rationale supporting design and test choices.
Applications
ISO 13232-3 is intended for research programs evaluating proposed motorcycle rider protective systems, including:
- Development and laboratory evaluation of rider airbags, frame-mounted guards, helmet-integrated systems and other crash protective devices.
- Paired impact testing (comparisons of motorcycles with and without a protective device) to measure potential injury reduction by body region.
- Instrumented sled or full-vehicle impact tests that require anthropometric accuracy and repeatable dummy responses.
- Correlating dummy-measured loads/moments with injury risk in biomechanical research.
Who uses this standard
- Motorcycle OEM safety engineers and R&D teams
- Academic and government research laboratories studying rider protection
- Crash test labs developing test protocols for novel protective devices
- Anthropomorphic dummy manufacturers and calibration facilities
- Helmet and protective device designers requiring compatible dummy interfaces
Related standards
- ISO 13232 series (other parts covering test procedures and analysis)
- Anthropometric/ATD guidance and component standards (e.g., reference to Hybrid III interfaces in annexes)
Keywords: ISO 13232-3:2005, motorcyclist anthropometric impact dummy, motorcycle safety testing, frangible components, neck dynamic test, dummy certification, paired impact tests, research evaluation.
Технические детали
- Технический комитет
- ISO/TC 22/SC 38 - Motorcycles and mopeds
- SKU
- ISO 13232-3:2005
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
ISO 13232-3:2005/Amd 1:2012
ДействующийMotorcycles — Test and analysis procedures for research evaluation of rider crash protective devices fitted t…
Overview ISO 13232-3:2005/Amd 1:2012 is an important international standard established by the International Organization for Standardization (ISO) focusing on motorcycle safety testing. This amendme…
BS ISO 13232-4:2005
ДействующийMotorcycles. Test and analysis procedures for research evaluation of rider crash protective devices fitted to…
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…