ISO 13362:2000 PDF
Flexible cellular polymeric materials — Determination of compression set under humid conditions
Flexible cellular polymeric materials — Determination of compression set under humid conditions
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 3
- Дата публикации:
- 2 ноября 2000 г.
- Издание:
- ISO IS 13362 edition 1 version 1
- ICS:
- 83.100
This International Standard specifies a method for determining the compression set of flexible cellular materials under humid conditions. This method consists of maintaining the test piece under specified conditions of time, temperature, humidity and constant compressive strain and determining the effect on the thickness of the test piece after a specified recovery period.
Abstract
Overview
ISO 13362:2000 provides an internationally recognized method for determining the compression set of flexible cellular polymeric materials under humid conditions. The standard specifies procedures for subjecting test pieces to defined time, temperature, humidity, and compressive strain, and for measuring the impact of these conditions on material thickness after recovery. This method is essential for manufacturers and quality assurance professionals who require consistent performance data for materials used in humid environments.
Key Topics
-
Scope and Usage The standard applies to flexible cellular materials, including foams and sponges based on various polymers, where resistance to permanent deformation in humid conditions is critical.
-
Testing Conditions The method involves compressing the sample to a specified percentage of its original thickness, exposing it to high humidity (95% - 100% RH) and elevated temperature (around 40°C) for a defined duration, then allowing a recovery period before final measurement.
-
Sample Preparation and Conditioning Material samples must be prepared following strict guidelines regarding size, shape, and surface characteristics, and conditioned in controlled atmospheres to standardize results.
-
Calculation and Reporting The compression set is calculated as the percentage loss in thickness after recovery, relative to the original thickness. Reporting requirements ensure traceability and reproducibility of results.
Applications
ISO 13362:2000 is widely used in industries where flexible cellular polymeric materials are subjected to variable humidity, such as:
-
Automotive and Transportation For seating, gaskets, and acoustic insulation materials that must retain shape and performance in humid climates or after exposure to moisture.
-
Building and Construction In insulation and sealing products where resistance to permanent deformation from compression under moisture is essential for energy efficiency and structural integrity.
-
Consumer Goods For packaging, mattresses, cushions, and footwear components that require durability and consistent cushioning over time, even in damp conditions.
-
Quality Control and R&D Laboratories and manufacturers employ this standard to benchmark product formulations, improve material resilience, and ensure compliance with international specifications.
Related Standards
While ISO 13362:2000 is the primary standard for compression set testing under high humidity, the following are commonly referenced or complementary standards:
-
ISO 1923:1981 - Cellular plastics and rubbers - Determination of linear dimensions This standard provides procedures for measuring the dimensions of plastics and rubber materials, referenced in ISO 13362 for sample measurement methods.
-
ISO/IEC Directives - Governing general procedures for drafting and approving international standards.
-
Other ISO Standards for Polymeric Materials Additional ISO documents may specify methods for testing tensile strength, elongation, or thermal stability of flexible foams and cellular products.
Practical Value
Implementing the procedures set out in ISO 13362:2000 ensures reliable, reproducible data on the compression set properties of flexible cellular materials exposed to humid conditions. This supports:
- Material selection and design optimization for specific environmental demands
- Improved product durability, safety, and customer satisfaction
- Compliance with global procurement and regulatory requirements
By standardizing the testing approach, organizations can benchmark materials, drive innovation, and maintain high quality across manufacturing batches for foam and cellular polymeric products intended for humid environments.
Технические детали
- Технический комитет
- ISO/TC 45/SC 4 - Products (other than hoses)
- SKU
- ISO 13362:2000
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
ISO 1923:1981
ДействующийCellular plastics and rubbers — Determination of linear dimensions
Overview ISO 1923:1981 is an international standard that specifies methods for the determination of linear dimensions of cellular plastics and rubbers, including both flexible and rigid materials. Th…
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…
ISO/ASTMTR52917-EB
ДействующийAdditive Manufacturing — Round Robin Testing — General Guidelines
This document outlines the steps with regard to aspects of design to conduct and run a round robin study (RRS) to assess the degree of variability in an additive manufacturing material or process. Th…