ISO 13693-2:2015 specifies the construction and performance requirement and test methods for metal-bodied chemigation valves with water at temperatures not exceeding 50 °C, which might contain fertilizers and chemicals of the types and concentration used in agriculture. The valve is designed to prohibit backflow caused by either back pressure or back siphonage. It is not designed for use in potable water systems. It is not to be confused with other forms of backflow prevention devices including pressure vacuum breakers, double check valves, reduced pressure zone valves, or goose neck loops. ISO 13693-2:2015 specifies the minimum design, construction, and performance testing requirements for the chemigation valve assembly. The assembly consists of the following components: ? a valve body into which a spring-loaded check valve is mounted with a resilient disk cover on the sealing surface; a combination air release/vacuum relief valve located upstream of the check valve; a low pressure drain valve located upstream of the check valve; an inspection port located so as to permit visual and manual inspection of the valve working components.
Abstract
Overview
ISO 13693-2:2015 specifies construction, performance requirements and test methods for metal-bodied chemigation valve assemblies used in agricultural irrigation (sizes DN 75 / 3" to DN 350 / 14"). It covers valves intended to work with irrigation water (≤ 50 °C) that may contain fertilizers or common agricultural chemicals, and is focused on preventing backflow (both back pressure and back siphonage) that could contaminate irrigation wells or other pressurized water supplies. The standard explicitly excludes use in potable water systems.
Key Topics and Technical Requirements
- Valve assembly components: valve body with spring-loaded check and resilient disk cover, upstream combination air release/vacuum relief valve, upstream low-pressure drain valve, and an inspection port for manual/visual inspection.
- Design requirements:
- Full flow in open position; watertight seal on reverse flow.
- Air vent/vacuum relief must act on pump start-up and shut-down.
- Low-pressure drain opens at atmospheric pressure and remains open until ≥ 15 kPa is present.
- Inspection port must provide at least 115 mm clearance and be hand-removable for pressure tests.
- Injection port downstream of the check valve to promote mixing and minimize chemical contact with the valve body.
- Removable components for inspection/replacement; chemical-resistant materials.
- Maximum average velocity through the valve limited to 3.0 m/s (stated maximum flow rate).
- Low-pressure drain nominal internal diameter ≥ 15 mm.
- Performance and testing:
- Mechanical strength and resistance to internal pressure (e.g., specified pressure tests such as 1 MPa for 5 min in preparation steps).
- Tests for hydraulic characteristics, vacuum relief behavior, elevated temperature, endurance, and acoustic properties.
- Permissible measurement deviations: flow/pressure ±2 %, temperature 23 °C ±5 °C, time ±1 %.
- Conformity assessment: type tests, production control, marking, technical documentation and packaging requirements.
Applications
- Mainline chemigation check valve assemblies for pressurized agricultural irrigation systems.
- Preventing backflow of injected chemicals into wells and protecting groundwater.
- Used wherever chemicals (fertilizers, pesticides) are injected into irrigation lines and reliable backflow prevention and inspection capability are required.
Who Uses This Standard
- Irrigation equipment manufacturers and valve designers
- Agricultural system integrators and farm irrigation engineers
- Test laboratories and conformity assessment bodies
- Agricultural safety officers, procurement teams, and regulatory authorities
Related Standards
- ISO 9635-1:2014 - Agricultural irrigation equipment - Irrigation valves - Part 1: General requirements (normative reference)
- EN 1267:1999 - Industrial valves - Test of flow resistance using water as a test fluid (normative reference)
Keywords: ISO 13693-2:2015, chemigation valve, chemigation valve assembly, irrigation safety, backflow prevention, metal-bodied chemigation valves, agricultural irrigation standards.
Технические детали
- Технический комитет
- ISO/TC 23/SC 18 - Irrigation and drainage equipment and systems
- SKU
- ISO 13693-2:2015
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
ISO 9635-1:2014
ДействующийAgricultural irrigation equipment — Irrigation valves — Part 1: General requirements
Overview ISO 9635-1:2014 - "Agricultural irrigation equipment - Irrigation valves - Part 1: General requirements" defines the construction, performance requirements and test methods for irrigation va…
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…
ISO/ASTMTR52917-EB
ДействующийAdditive Manufacturing — Round Robin Testing — General Guidelines
This document outlines the steps with regard to aspects of design to conduct and run a round robin study (RRS) to assess the degree of variability in an additive manufacturing material or process. Th…