ISO 15011-1:2009 PDF
Health and safety in welding and allied processes — Laboratory method for sampling fume and gases — Part 1: Determination of fume emission rate during arc welding and collection of fume for analysis
Health and safety in welding and allied processes — Laboratory method for sampling fume and gases — Part 1: Determination of fume emission rate during arc welding and collection of fume for analysis
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 20
- Дата публикации:
- 5 октября 2009 г.
- Издание:
- ISO IS 15011 edition 2 version 1
- ICS:
- 13.100
ISO 15011-1:2009 defines a laboratory method for measuring the emission rate of fume from arc welding. It also defines a method of collecting the fume for subsequent analysis and refers to suitable analytical techniques. The methods described are suitable for use with all open arc welding processes except tungsten inert gas (TIG) welding, which produces little fume.
Abstract
Overview
ISO 15011-1:2009 - Health and safety in welding and allied processes - Part 1 specifies a laboratory method for determining fume emission rate during arc welding and for collecting welding fume for subsequent analysis. The standard covers open arc welding processes (excluding TIG, which produces little fume) and defines the test principle, required equipment, test procedures and reporting essentials used in controlled emission-rate testing.
Key topics and technical requirements
- Test principle: measure mass of fume collected on a pre-weighed filter and divide by arcing time to give fume emission rate (mg/s).
- Test chamber: semi-enclosed, continuously extracted enclosure (types include a “hood” or “fume box”) designed to minimize deposition on internal surfaces and to contain all generated fume. Extraction should clear the chamber within 30 s after arc extinction.
- Filters and sampling:
- Glass or quartz-fibre filters for emission-rate weighing (robust and non-friable).
- Paper (cellulose) filters for fume collection intended for chemical analysis.
- Instrumentation accuracy:
- Balance: ±1 mg or better for filter mass measurements.
- Electrical and feed measurements (current, voltage, wire-feed): mean values within ±5% or better; arcing time to 0.1 s resolution.
- Shielding-gas flow measurement: calibrated to ±5% or better.
- Processes covered: manual metal arc (MMA) and continuous wire processes (MIG/MAG, MCAW, FCAW, SSFCAW). Automatic welding is recommended for continuous-wire processes to improve reproducibility.
- Procedures: trial tests to set current and arcing time, controlled welding positions, precautions to avoid sample loss and chamber leakage, and guidance on test-piece preparation.
- Ancillary content: informative annexes on chamber designs, equipment notes and welding parameters; normative annexes for procedural details and test reporting.
Practical applications
- Evaluate and compare fume emission rates of welding consumables, wires and electrodes.
- Determine effects of welding parameters, shielding gases, process type and test-piece condition on fume generation and composition.
- Support occupational hygiene assessments, product development and cleaner-process selection.
- Provide standardized input for fume data sheets and research studies on welding emissions.
Who should use this standard
- Occupational hygienists and safety professionals assessing welding exposures.
- Welding engineers and production managers seeking lower-emission processes or consumables.
- Test laboratories performing standardized welding fume measurements.
- Manufacturers of welding consumables preparing emission data for customers or regulatory compliance.
Related standards
- ISO 15011 series: Parts 2 (gases), 3 (ozone), 4 (fume data sheets), 5 (thermal-degradation products); Part 6 under development.
- ISO/TR 25901 (welding vocabulary) and ISO/IEC Guide 98-3 (uncertainty of measurement) are normative references.
Keywords: ISO 15011-1:2009, fume emission rate, welding fume sampling, arc welding, laboratory method, test chamber, welding fume analysis, occupational hygiene.
Технические детали
- Технический комитет
- ISO/TC 44/SC 9 - Health and safety
- SKU
- ISO 15011-1:2009
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
BS EN ISO 15011-4:2018
ДействующийHealth and safety in welding and allied processes. Laboratory method for sampling fume and gases. Fume data s…
ISO/TR 25901:2007
ОтменёнWelding and related processes — Vocabulary
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…