ISO 15167:1999 PDF
Petroleum products — Determination of particulate content of middle distillate fuels — Laboratory filtration method
Petroleum products — Determination of particulate content of middle distillate fuels — Laboratory filtration method
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 8
- Дата публикации:
- 12 августа 1999 г.
- Издание:
- ISO IS 15167 edition 1 version 1
- ICS:
- 75.160.20
This International Standard specifies a method for the determination of the particulate content of middle distillate fuels with a closed flash point of 38 °C or higher, determined in accordance with ISO 2719, ISO 3679 or ISO 13736. It is not applicable to light distillate fuels (gasolines) or to aviation fuels. A gravimetric limitation of the contamination of middle distillate fuels used in diesel engines and domestic applications should be used for the control of filter plugging and other operational problems, and this procedure is applicable up to 25 g/m3. The precision of this procedure is only valid if the results are obtained strictly in accordance with the provisions of this International Standard, particularly in respect of the material used for the filter (see the note in 6.9), sample size and filtration of the complete sample.
Abstract
Overview - ISO 15167:1999 (Laboratory filtration method)
ISO 15167:1999 specifies a laboratory filtration method for determining the particulate content of middle distillate fuels (fuels with a closed flash point of 38 °C or higher). The method uses a gravimetric approach: a measured volume of fuel is passed through pre-weighed membrane filters and the mass increase of the test filter (relative to a control filter) gives particulate concentration expressed in grams per cubic metre (g/m3). The procedure is applicable up to 25 g/m3 and is not intended for light distillate fuels (gasolines) or aviation fuels.
Key topics and technical requirements
- Scope and applicability: Middle distillate fuels only; closed flash point ≥ 38 °C; excludes gasoline and aviation fuels.
- Principle: Filtration of a specified sample volume through a pre-weighed test membrane filter with an underlying control membrane; determine particulate mass by gravimetric increase after washing and drying.
- Filter media: 47 mm diameter membrane filters of nominal porosity 0,8 mm (test and control). Note: precision data were obtained using nylon filters.
- Reagents and flushing fluids: Propan-2-ol (isopropyl alcohol) for rinsing and heptane or 2,2,4‑trimethylpentane as flushing fluid; use water of analytical grade (ISO 3696).
- Apparatus: Analytical balance (0.1 mg accuracy), static oven at 90 °C, vacuum filtration system, receiving and safety flasks, grounded/bonded components, air ionizer for weighing environment.
- Sampling and preparation: Strict cleaning of sample containers and apparatus, controlled sample volumes, avoidance of contamination, dynamic sampling preferred (ISO 3170 / ISO 3171 principles).
- Precision and reporting: Results are only valid when procedure, sample size, filter material, and complete filtration requirements are strictly followed. Test report must document conditions and any deviations.
Applications and users
ISO 15167 is used by:
- Fuel testing laboratories and QC departments in refineries and distribution terminals
- Pipeline and storage operators monitoring fuel cleanliness
- Diesel engine and equipment manufacturers concerned with filter plugging and operational reliability
- Suppliers and purchasers performing acceptance testing and contamination control Practical applications include monitoring particulate contamination to prevent filter blockage, diagnosing operational fuel problems, and establishing gravimetric contamination limits for diesel and domestic heating fuels.
Related standards
- ISO 2719, ISO 3679, ISO 13736 - flash point methods (referenced for fuel classification)
- ISO 3170 / ISO 3171 - sampling of petroleum liquids
- ISO 3696 - water for laboratory use
- ISO 4259 - precision and application of precision data
Keywords: ISO 15167:1999, particulate content, middle distillate fuels, laboratory filtration method, membrane filters, gravimetric determination, fuel cleanliness, filter plugging.
Технические детали
- Технический комитет
- ISO/TC 28 - Petroleum and related products, fuels and lubricants from natural or synthetic sources
- SKU
- ISO 15167:1999
Похожие стандарты
Стандарты, упомянутые в описании
SIST EN ISO 3696:1998
ДействующийWater for analytical laboratory use - Specification and test methods (ISO 3696:1987)
Overview EN ISO 3696:1995 (ISO 3696:1987) – "Water for analytical laboratory use – Specification and test methods" is a CEN-adopted international standard that defines quality grades, specification l…
ISO 31700-1:2023
ДействующийConsumer protection — Privacy by design for consumer goods and services — Part 1: High-level requirements
Overview ISO 31700-1:2023 provides high-level requirements for “privacy by design” in consumer goods and services. Issued by the International Organization for Standardization (ISO), this part of the…
SIST EN ISO 3171:1999
ДействующийPetroleum liquids - Automatic pipeline sampling (ISO 3171:1988)
Overview EN ISO 3171:1999 (identical to ISO 3171:1988) covers recommended procedures for automatic pipeline sampling of petroleum liquids, principally crude oil and liquid petroleum products conveyed…
SIST EN ISO 2719:2026
ДействующийDetermination of flash point - Pensky-Martens closed cup method (ISO 2719:2025)
Overview - EN ISO 2719:2025 (Pensky‑Martens closed cup method) EN ISO 2719:2025, published by CEN and identical to ISO 2719:2025, defines the Pensky‑Martens closed cup method for the determination of…
SIST EN ISO 3679:2023
ДействующийDetermination of flash point - Method for flash no-flash and flash point by small scale closed cup tester (IS…
Overview EN ISO 3679:2022 (Corrected version 2023-05) specifies methods for determining the flash no‑flash result and the flash point using a small scale closed cup tester. Published by CEN and align…
ISO 13736:2021/Amd 1:2022
ДействующийDetermination of flash point — Abel closed-cup method — Amendment 1: Bias statement update
Overview ISO 13736:2021/Amd 1:2022 is an important amendment to the international standard governing the determination of flash point using the Abel closed-cup method. Issued by the International Org…
SIST EN ISO 4259-5:2024
ДействующийPetroleum and related products - Precision of measurement methods and results - Part 5: Statistical assessmen…
Overview EN ISO 4259-5:2024 (ISO 4259-5:2023, corrected 2024-03) defines a statistical procedure to assess the agreement between two different measurement methods that claim to measure the same quant…