ISO 15858:2016 PDF
UV-C Devices — Safety information — Permissible human exposure
UV-C Devices — Safety information — Permissible human exposure
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 7
- Дата публикации:
- 4 июля 2016 г.
- Издание:
- ISO IS 15858 edition 1 version 1
- ICS:
- 91.140.30
ISO 15858:2016 specifies minimum human safety requirements for the use of UVC lamp devices. It is applicable to in-duct UVC systems, upper-air in room UVC systems, portable in-room disinfection UVC devices, and any other UVC devices which may cause UVC exposure to humans. It is not applicable to UVC products used for water disinfection.
Abstract
Overview - ISO 15858:2016 (UV-C Devices - Safety information - Permissible human exposure)
ISO 15858:2016 defines minimum human-safety requirements for the use of UV‑C (UVC) lamp devices used for air and surface disinfection. The standard covers in-duct UVC systems, upper‑air room UVC fixtures, portable in‑room disinfection devices and any UVC equipment that may cause human exposure. It does not apply to UVC products intended for water disinfection. Key goals are to limit ocular and skin exposure, specify measurement and assessment methods, and prescribe control measures such as PPE, signage and training.
Key technical topics and requirements
- Permissible exposure limits: Adopts NIOSH REL / ACGIH TLV guidance - maximum permissible UVC exposure at 254 nm is 6.0 mJ/cm² for an 8‑hour day (tabled values show corresponding irradiance and permissible exposure times).
- Sources and use cases: Defines in‑duct systems, upper‑air fixtures and portable in‑room devices and describes UVC behavior (low penetration, reflection from some surfaces, transmission through certain materials).
- Measurement and instrumentation:
- Use radiometers/radiometers compliant with EN 14255‑1.
- Hand‑held sensors tuned to ~240–270 nm for on‑site checks; 254 nm‑selective radiometers for eye‑level measurements.
- Eye‑level measurement height specified (approx. 1.83 m–2.13 m / 6.0–7.0 ft) and guidance on measurement locations and frequency (commissioning, lamp replacement, system modification).
- Thresholds & commissioning:
- Procedures for measuring and comparing effective irradiance against exposure limits.
- Actions required when readings exceed limits (e.g., deactivation until adjustments or manufacturer advice).
- Controls and PPE:
- Requirement for UV‑resistant eyewear (comply with EN 170) and skin‑covering clothing when exposures exceed permissible levels.
- Signage and marking of areas subject to UVC exposure.
- Training and communication: Personnel must be informed about measured exposure levels, risks and safe work practices.
Practical applications and who uses this standard
ISO 15858 is used by:
- HVAC designers and building engineers specifying in‑duct UVC for coil/air sanitation
- Facilities managers and infection‑control teams selecting upper‑air or portable UVC units
- Safety officers performing commissioning, risk assessments and routine UVC monitoring
- Manufacturers of UVGI equipment for labeling, instructions and safer product design
Practical benefits include consistent measurement methods, clear exposure limits for occupational safety, and guidance to reduce acute ocular and cutaneous effects.
Related standards and references
- EN 170:2002 (UV filters for eye protection)
- EN 14255‑1:2005 (measurement of personal exposures to UV)
- CDC/NIOSH REL and ACGIH TLV guidance (adopted exposure limits)
- CIE reviews cited for long‑term risk assessment
For safe UV‑C deployment, follow ISO 15858 measurement, PPE and training recommendations alongside local occupational regulations.
Технические детали
- Технический комитет
- ISO/TC 142 - Cleaning equipment for air and other gases
- SKU
- ISO 15858:2016
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
SIST EN ISO 15858:2016
ДействующийUV-C Devices - Safety information - Permissible human exposure (ISO 15858:2016)
Overview EN ISO 15858:2016 (ISO 15858:2016) - titled "UV‑C Devices - Safety information - Permissible human exposure" - establishes minimum human‑safety requirements for the use of UVC lamp devices.…
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…
ISO/ASTMTR52917-EB
ДействующийAdditive Manufacturing — Round Robin Testing — General Guidelines
This document outlines the steps with regard to aspects of design to conduct and run a round robin study (RRS) to assess the degree of variability in an additive manufacturing material or process. Th…