ISO 15989:2004 specifies a method of measuring the contact angle of water droplets on corona-treated polymer film surfaces and subsequently determining the wetting tension of the film. The method is applicable to practically any polymer film. It is not applicable, however, if the surface of the film exhibits a chemical affinity for water.
Abstract
Overview
ISO 15989:2004 defines a standardized laboratory method for measuring the water-contact angle of corona-treated polymer films and converting that value into an estimated wetting tension (surface energy). The procedure covers droplet deposition, optical measurement and basic result interpretation for virtually any polymer film - except films whose surfaces chemically attract water (i.e., show intrinsic water affinity). ISO 15989 is used for process control, quality assurance and comparative testing of corona surface treatment on film and sheeting.
Key topics and technical requirements
- Scope and applicability: Contact-angle measurement of corona-treated films; not applicable when the film surface has chemical affinity for water.
- Test liquid: Use distilled or ultra‑pure water (HPLC-grade) - contamination alters results; reagent-grade deionized water is less accurate.
- Specimens: Minimum strip ~25 mm × 300 mm; note machine direction when sampling; avoid touching test areas.
- Sampling: Recommended 10 readings per specimen; advance specimen between droplets to avoid previously wetted areas.
- Droplet transfer and size: Typical droplets ~1–2 µL (larger 5–8 µL possible but may introduce error). Transfer droplet from a microsyringe; do not squirt.
- Apparatus:
- Contact‑angle meter (goniometer) with appropriate optics and microsyringe.
- Droplet‑projection contact‑angle apparatus (user‑constructed alternative).
- Computer‑based image analysis systems for higher accuracy.
- Measurement techniques: Direct tangent/protractor, geometric methods using apex/three‑phase point, or image-dimension algorithms (per ASTM D724 / ASTM D5946). Measure within about 1 minute of droplet transfer.
- Calculation & interpretation: Compute average and standard deviation of measured angles; use the standard conversion chart (Table 1) to estimate wetting tension (e.g., a 70° contact angle ≈ 41 mN/m).
- Conditioning: Generally not required for routine QC. For interlaboratory comparisons, condition specimens (≈23 °C ±2 °C and 50 % ±5 % RH for ≥40 h).
- Precision: Interlaboratory data exist (see standard); instrument and operator biases should be assessed.
Applications and users
ISO 15989 is valuable for:
- Film manufacturers and converters controlling corona treatment effectiveness
- Packaging and printing converters checking surface wettability for inks, coatings and adhesives
- Quality assurance and production process control laboratories
- Independent test laboratories and research groups studying surface energy and adhesion of polymer films
Keywords: ISO 15989, contact angle measurement, corona-treated films, wetting tension, surface energy, polymer film, goniometer, water-contact angle.
Related standards
- ASTM D5946 - Corona‑treated polymer films using water contact angle
- ASTM D724 - Surface wettability (angle‑of‑contact method)
- ASTM E691 / ISO 5725‑2 - Precision and interlaboratory study methods
For implementation, consult the full ISO 15989:2004 text for complete procedures, tables and reporting requirements.
Технические детали
- Технический комитет
- ISO/TC 61/SC 11 - Products
- SKU
- ISO 15989:2004
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
SIST ISO 5725-2:2020
ДействующийAccuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determina…
Overview SIST ISO 5725-2:2020 (equivalent to ISO 5725-2:2019) defines the basic method for estimating the precision of a standard measurement method by means of a collaborative interlaboratory experi…
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…
ISO/ASTMTR52917-EB
ДействующийAdditive Manufacturing — Round Robin Testing — General Guidelines
This document outlines the steps with regard to aspects of design to conduct and run a round robin study (RRS) to assess the degree of variability in an additive manufacturing material or process. Th…