ISO 16975-3:2017 PDF
Respiratory protective devices — Selection, use and maintenance — Part 3: Fit-testing procedures
Respiratory protective devices — Selection, use and maintenance — Part 3: Fit-testing procedures
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 28
- Дата публикации:
- 29 сентября 2017 г.
- Издание:
- ISO IS 16975 edition 1 version 1
- ICS:
- 13.340.30
ISO 16975-3:2017 specifies guidance on how to conduct fit testing of tight-fitting respiratory protective device (RPD) and on appropriate methods to be used. Fit testing is only one element of a complete RPD programme. The intention of fit testing is to evaluate the effectiveness of the seal between the wearer's face and the respiratory interface (RI). A complete RPD programme is defined in ISO/TS 16975‑1. ISO 16975-3:2017 specifies requirements for conducting RPD fit testing and includes - qualifications/competences of fit-test operators, - specific fit-testing procedures, - interpretation of fit-test results, and - record keeping. A fit test is not required for escape-only RPD.
Abstract
Overview
ISO 16975-3:2017 - "Respiratory protective devices - Selection, use and maintenance - Part 3: Fit-testing procedures" provides guidance and requirements for conducting fit testing of tight-fitting respiratory protective devices (RPD). The standard defines the purpose of fit testing (to evaluate the seal between the wearer’s face and the respiratory interface), describes both qualitative and quantitative methods, and positions fit testing as one essential element of a complete RPD programme (see ISO/TS 16975‑1). A fit test is not required for escape-only RPD.
Key Topics and Requirements
- Competence of fit-test operators: qualifications, knowledge of RPD and fit-test methods, ability to set up and monitor equipment, and to identify causes of fit-test failure.
- Fit-test procedures: detailed instructions for qualitative fit testing (QLFT) and quantitative fit testing (QNFT), including aerosol and vapour challenge agents (e.g., isoamyl acetate/banana oil), ambient aerosol CNC methods, generated aerosol procedures, and controlled negative-pressure (CNP) techniques.
- Interpretation and acceptance criteria: definitions of qualitative fit factor (QLFF), quantitative fit factor (QNFF) and required fit factor (RFF) used to assess pass/fail outcomes.
- Practical test elements: subject briefing, exercise protocols during testing, taste-threshold screening for QLFT, and sampling requirements for aerosol systems.
- Program considerations: medical clearance, training for RPD wearers, frequency of fit testing, effects of facial hair, foreign materials, or other PPE that may interfere with the seal.
- Record keeping: documentation requirements for fit-test results and operator records.
- Annexes and supporting content: examples of operator evaluation forms, explanation of RFFs, and criteria for validating new fit-test methods.
Applications and Users
Who uses ISO 16975-3:2017:
- Occupational health & safety managers and RPD programme administrators - to design and maintain fit-testing programmes.
- Competent fit-test operators and trainers - to meet minimum competency and procedural expectations.
- Occupational hygienists and safety consultants - for selecting appropriate fit-test methods and interpreting results.
- Employers in industries with airborne hazards (manufacturing, construction, healthcare, mining) - to verify respiratory protection effectiveness.
- PPE manufacturers and regulators - to align product guidance and compliance with international best practice.
Related Standards
- ISO/TS 16975‑1 - complete RPD programme guidance
- ISO/TS 16975‑2 - (related parts of the ISO 16975 series addressing selection and use)
- Other ISO standards on RPD performance and terminology referenced within the series
Keywords: ISO 16975-3:2017, respiratory protective devices, fit testing, RPD, qualitative fit test, quantitative fit test, fit-test operator, RPE program.
Технические детали
- Технический комитет
- ISO/TC 94/SC 15 - Respiratory protective devices
- SKU
- ISO 16975-3:2017
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
PD ISO/TS 16975-1:2016
Respiratory protective devices. Selection, use and maintenance - Establishing and implementing a respiratory…
What is ISO/TS 16975-1 -R espiratory protective device (RPD) programme about? ISO/TS 16975 is an international standard on the selection, use and maintenance of respiratory protective devices. ISO/TS…
PD ISO/TS 16975-2:2016
ДействующийRespiratory protective devices. Selection, use and maintenance - Condensed guidance to establishing and imple…
What is ISO/TS 16975-2 - Respiratory protective device about? ISO/TS 16975-2 is the second part of an international standard used for Respiratory protective devices. ISO/TS 16975-2 can help in implem…
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…