ISO 16976-1:2022 PDF
Respiratory protective devices — Human factors — Part 1: Metabolic rates and respiratory flow rates
Respiratory protective devices — Human factors — Part 1: Metabolic rates and respiratory flow rates
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 18
- Дата публикации:
- 18 октября 2022 г.
- Издание:
- ISO IS 16976 edition 1 version 1
- ICS:
- 13.340.30
This document provides information on factors related to human anthropometry, physiology, ergonomics, and performance for the preparation of standards for performance requirements, testing, and use of respiratory protective devices. This document contains information related to respiratory and metabolic responses to rest and work at various intensities. Information is provided for the following: metabolic rates associated with various intensities of work; oxygen consumption as a function of metabolic rate and minute ventilation for persons representing three body sizes; peak inspiratory flow rates during conditions of speech and no speech for persons representing three body sizes as a function of metabolic rates. The information contained within this document represents data for healthy adult men and women of approximately 30 years of age, but is considered to be applicable for the age range of the worker population.
Abstract
Overview
ISO 16976-1:2022 - "Respiratory protective devices - Human factors - Part 1: Metabolic rates and respiratory flow rates" provides human physiological and anthropometric data needed to develop performance requirements, test methods, and use guidance for respiratory protective devices (RPD). The document links metabolic rate, oxygen consumption, minute ventilation, and peak inspiratory flow (PIFR), and gives representative values for three body sizes. Data represent healthy adult men and women (≈30 years) and are intended to be applicable across the worker population.
Key topics
- Metabolic rate classes: Defines work intensity categories (resting to maximal) with metabolic rates (W/m²), including added high-intensity classes relevant to firefighting/rescue.
- Oxygen consumption (V̇O2): Relationship between metabolic rate and oxygen uptake; formulas and conversion factors for estimating V̇O2 from metabolic rate.
- Minute ventilation (V̇E): How oxygen consumption maps to required air volume per minute; typical multipliers between V̇O2 and V̇E at different activity levels.
- Peak inspiratory flow rate (PIFR): Values for inhalation peak flows during speech and non‑speech conditions, expressed in l/s BTPS.
- Representative body sizes: Example subjects used for calculations - small (60 kg, 1.70 m, A = 1.69 m²), medium (70 kg, 1.75 m, A = 1.84 m²), large (85 kg, 1.88 m, A = 2.11 m²).
- Units and standards terminology: Use of STPD/BTPS/ATPS conventions, and terms such as aerobic energy production, minute ventilation, and PIFR.
- Informative examples: Annex material showing practical calculation use-cases (e.g., converting MR → V̇O2 → V̇E → PIFR).
Applications
ISO 16976-1 is practical for:
- RPD designers and manufacturers - to size breathing circuits, select filter characteristics, design exhalation/inhalation valves, and evaluate breathing resistance across work intensities.
- Test laboratories and standards developers - to create realistic test protocols that account for metabolic demands, speech effects, and peak flows.
- Occupational safety professionals and respirator program managers - to match respirator types to job tasks and anticipated physiological loads (e.g., firefighting, rescue, heavy manual work).
- Regulatory bodies and certification organizations - to set performance requirements and verification limits tied to human respiratory demands.
Practical benefits include improved respirator fit, reduced breathing work, more realistic endurance and leakage testing, and better PPE selection for different work classes.
Who should use this standard
- PPE manufacturers, respirator test labs, standards committees, occupational hygienists, safety engineers, and anyone involved in respirator selection, certification, or physiological risk assessment.
Related standards
- ISO 8996 (measurement and assessment of metabolic rate) - referenced for metabolic-class foundations.
- Other parts of the ISO 16976 series covering human factors for respiratory protective devices.
Keywords: ISO 16976-1, respiratory protective devices, metabolic rates, respiratory flow rates, oxygen consumption, minute ventilation, peak inspiratory flow, human factors, respirator testing, PPE design.
Технические детали
- Технический комитет
- ISO/TC 94/SC 15 - Respiratory protective devices
- SKU
- ISO 16976-1:2022
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
SIST EN ISO 8996:2022
ДействующийErgonomics of the thermal environment - Determination of metabolic rate (ISO 8996:2021)
Overview EN ISO 8996:2021 - Ergonomics of the thermal environment: Determination of metabolic rate specifies standardized methods to estimate human metabolic rate in the context of thermal comfort, h…
BS ISO 16976-6:2023
ДействующийRespiratory protective devices. Human factors. Psycho-physiological effects.
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…