ISO 17736:2010 PDF
Workplace air quality — Determination of isocyanate in air using a double-filter sampling device and analysis by high pressure liquid chromatography
Workplace air quality — Determination of isocyanate in air using a double-filter sampling device and analysis by high pressure liquid chromatography
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 27
- Дата публикации:
- 26 ноября 2010 г.
- Издание:
- ISO IS 17736 edition 1 version 1
- ICS:
- 13.040.30
ISO 17736:2010 gives general guidelines for the sampling and analysis of airborne isocyanates in workplace air. ISO 17736:2010 is appropriate for organic compounds containing free isocyanate functional groups and is specific for the quantification of monomers, polymers and prepolymers, vapours and aerosols. Differential air sampling is performed with a segregating device which can show the physical state of the isocyanates analysed as found in the field. This capacity, however, may show limitations for given situations, e.g. when aerosols collected on the first filter contain free monomer that migrates to the second filter and is then quantified as vapour phase isocyanate. The determination of aromatic monomers includes toluene diisocyanate (TDI) and 4,4'-diisocyanato-diphenylmethane (MDI). Aliphatic monomers include isophorone diisocyanate (IPDI), 4,4'-methylene bis-(cyclohexyl isocyanate) (HMDI) and 1,6-hexamethylene diisocyanate (HDI). Isocyanate oligomers and prepolymers can also be determined using this method. The double-filter method is designed to determine short-term (15 min) exposure concentrations of organic isocyanates in a workplace environment by personal monitoring or by fixed location monitoring. However, if the exposure is expected to be in vapour form only, then sampling time can be extended to 8 h. Since the filter is derivatized in the field immediately after sampling, loss of isocyanate aerosol because of its reaction with other chemicals is negligible except for very fast-reacting isocyanate systems such as foam spraying of MDI in polyurethane applications. The method is suitable for the measurement of airborne organic isocyanates in the NCO equivalent concentration range of 0,01 µg/sample to 2,1 µg/sample, corresponding to approximately 0,67 µg/m3 to 140 µg/m3 for a 15 l sample volume. This range brackets about eight times the current established threshold limit value (TLV) of 5 ppb for monomers set by many national authorities.
Abstract
Overview
ISO 17736:2010 - Workplace air quality - provides guidelines for sampling and analysis of airborne isocyanates in occupational environments using a double-filter sampling device and analysis by high performance liquid chromatography (HPLC). The method covers free isocyanate functional groups in monomers, oligomers and prepolymers in both vapour and aerosol phases (e.g., TDI, MDI, HDI, IPDI, HMDI). It is designed primarily for short‑term (15 min) personal or fixed‑location monitoring, with vapour‑only sampling extendable to 8 h.
Key topics and technical requirements
- Sampling train: 37 mm PTFE filter to collect aerosols followed by a glass fibre (GF) filter impregnated with MAMA to trap vapour; commercially available formats exist (e.g., ISO‑CHEK®).
- In-field derivatization: Aerosol filter is derivatized immediately after sampling with MP (1-(2‑methoxyphenyl)piperazine) to stabilize reactive isocyanates.
- Analysis by HPLC: Reversed‑phase HPLC with UV, fluorescence (FL) and diode array detectors (DAD) for separation, quantification and identification; FL used for low concentrations (
Технические детали
- Технический комитет
- ISO/TC 146/SC 2 - Workplace atmospheres
- SKU
- ISO 17736:2010
Похожие стандарты
Другие стандарты ISO
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…
ISO/ASTMTR52917-EB
ДействующийAdditive Manufacturing — Round Robin Testing — General Guidelines
This document outlines the steps with regard to aspects of design to conduct and run a round robin study (RRS) to assess the degree of variability in an additive manufacturing material or process. Th…
ISO/ASTM52901-17(2023)
ДействующийStandard Guide for Additive Manufacturing – General Principles – Requirements for Purchased AM Parts
Scope 1.1 This document defines and specifies requirements for purchased parts made by additive manufacturing. 1.2 It gives guidelines for the elements to be exchanged between the customer and the pa…