ISO 18755:2022 PDF
Fine ceramics (advanced ceramics, advanced technical ceramics) — Determination of thermal diffusivity of monolithic ceramics by flash method
Fine ceramics (advanced ceramics, advanced technical ceramics) — Determination of thermal diffusivity of monolithic ceramics by flash method
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 42
- Дата публикации:
- 13 декабря 2022 г.
- Издание:
- ISO IS 18755 edition 2 version 1
- ICS:
- 81.060.30
This document specifies the test method for the determination of thermal diffusivity from room temperature to at least 1 700 K by the flash method for homogeneous monolithic ceramics with porosity less than 10 %. Flash methods, like laser flash, are applicable to homogeneous isotropic materials with thermal diffusivity values ranging from 0,1 to 1 000 mm2 s-1 within the temperature range from approximately 100 K to 2 300 K. The method described in Annex G describes how to estimate, on the basis of the thermal diffusivity test, the specific heat capacity and the thermal conductivity of homogeneous monolithic ceramics with porosity less than 10 %.
Abstract
Overview
ISO 18755:2022 specifies the standardized test method for determining thermal diffusivity of monolithic fine ceramics (advanced/technical ceramics) using the flash method (e.g., laser flash). The standard covers measurements from room temperature to at least 1 700 K for homogeneous monolithic ceramics with porosity < 10 %. Flash methods are applicable to isotropic materials with thermal diffusivity in the range 0.1 to 1 000 mm2·s‑1 and broadly across temperatures from ≈100 K up to ≈2 300 K. Annex G describes how to estimate specific heat capacity and thermal conductivity from the measured thermal diffusivity.
Key technical topics and requirements
- Scope and specimen limits: Homogeneous monolithic ceramics, porosity < 10 %; specimen geometry and density requirements are defined (see ISO 18755 for specifics).
- Flash source: Pulse laser, flash lamp or equivalent capable of a short, high‑energy pulse; pulse duration preferably < 1.0 ms (FWHM) with uniform irradiation of the front face.
- Detection and timing: Rear-face transient temperature is recorded with a non-contact radiation thermometer or detector. Detector and electronics should have a frequency response > 10 kHz. Target detector area must be
Технические детали
- Технический комитет
- ISO/TC 206 - Fine ceramics
- SKU
- ISO 18755:2022