ISO 19130-1:2018 PDF
Geographic information — Imagery sensor models for geopositioning — Part 1: Fundamentals
Geographic information — Imagery sensor models for geopositioning — Part 1: Fundamentals
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 158
- Дата публикации:
- 5 сентября 2018 г.
- Издание:
- ISO IS 19130 edition 1 version 1
- ICS:
- 35.240.70
This document identifies the information required to determine the relationship between the position of a remotely sensed pixel in image coordinates and its geoposition. It supports exploitation of remotely sensed images. It defines the metadata to be distributed with the image to enable user determination of geographic position from the observations. This document specifies several ways in which information in support of geopositioning can be provided. a) It may be provided as a sensor description with the associated physical and geometric information necessary to rigorously construct a PSM. For the case where precise geoposition information is needed, this document identifies the mathematical equations for rigorously constructing PSMs that relate 2D image space to 3D ground space and the calculation of the associated propagated errors. This document provides detailed information for three types of passive electro-optical/ IR sensors (frame, pushbroom and whiskbroom) and for an active microwave sensing system SAR. It provides a framework by which these sensor models can be extended to other sensor types. b) It can be provided as a TRM, using functions whose coefficients are based on a PSM so that they provide information for precise geopositioning, including the calculation of errors, as precisely as the PSM they replace. c) It can be provided as a CM that provides a functional fitting based on observed relationships between the geopositions of a set of GCPs and their image coordinates. d) It can be provided as a set of GCPs that can be used to develop a CM or to refine a PSM or TRM. This document does not specify either how users derive geoposition data or the format or content of the data the users generate.
Abstract
Overview
ISO 19130-1:2018 - Geographic information - Imagery sensor models for geopositioning - Part 1: Fundamentals defines the geolocation information that imagery data providers must supply so users can determine ground positions from image coordinates. The standard specifies the metadata, sensor descriptions and modeling approaches needed to enable rigorous geopositioning for a variety of sensors and to promote interoperability of remotely sensed imagery.
Key topics and technical requirements
- Supported sensor types: passive electro-optical/IR frame, pushbroom, whiskbroom, and active microwave SAR (Synthetic Aperture Radar).
- Three model approaches (and GCPs):
- Physical Sensor Model (PSM) - rigorous sensor description with physical and geometric parameters; includes the mathematical basis for ground↔image transformations and propagated error calculations.
- True Replacement Model (TRM) - functional models whose coefficients are derived from a PSM to provide equivalent precision, including error characterization.
- Correspondence Model (CM) - functional fitting based on observed relationships (e.g., using GCPs).
- Ground Control Points (GCPs) - supplied as sets that can be used to build or refine CMs, TRMs or PSMs.
- Metadata requirements and schema: specifies the minimum geolocation metadata elements and provides a schema and data dictionary for exchange (Annex B normative).
- Calibration and quality: addresses geometric and radiometric calibration elements, model adjustability, error propagation, and quality metrics associated with PSMs and TRMs.
- Conformance and annexes: includes conformance/testing guidance (Annex A), coordinate system conventions (Annex C), and informative metadata profiles for frame, pushbroom/whiskbroom and SAR sensors (Annexes D–F).
Note: the standard defines the metadata and model forms to be provided - it does not prescribe how end-users derive geoposition results or the formats of user-generated outputs.
Practical applications and who uses this standard
ISO 19130-1 is essential for:
- Imagery data providers and commercial vendors - to publish standardized geolocation metadata with imagery products.
- GIS and remote sensing software developers - to implement interoperable geopositioning workflows (PSM/TRM/CM support).
- Photogrammetrists, surveyors and geospatial analysts - to perform precise image-to-ground and ground-to-image positioning, quality assessment and error budgeting.
- Government mapping agencies and emergency response teams - to integrate multi-source imagery reliably for mapping, change detection, disaster assessment, precision agriculture and environmental monitoring.
Related standards
- ISO 19130-1 replaces ISO/TS 19130:2010 and references other ISO geographic information standards for coordinate systems and metadata. Users should consult the ISO geographic information/geomatics series for complementary specifications on coordinate reference systems and metadata exchange.
Технические детали
- Технический комитет
- ISO/TC 211 - Geographic information/Geomatics
- SKU
- ISO 19130-1:2018
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
SIST ISO 19130-1:2019
ДействующийGeographic information -- Imagery sensor models for geopositioning -- Part 1: Fundamentals
Overview SIST ISO 19130-1:2019 - "Geographic information - Imagery sensor models for geopositioning - Part 1: Fundamentals" defines the geolocation information imagery data providers must supply so u…
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…
ISO/ASTMTR52917-EB
ДействующийAdditive Manufacturing — Round Robin Testing — General Guidelines
This document outlines the steps with regard to aspects of design to conduct and run a round robin study (RRS) to assess the degree of variability in an additive manufacturing material or process. Th…