ISO 19235:2015 PDF
Analogue quartz clocks — Timing accuracy
Analogue quartz clocks — Timing accuracy
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 7
- Дата публикации:
- 13 октября 2015 г.
- Издание:
- ISO IS 19235 edition 1 version 1
- ICS:
- 39.040.20
ISO 19235:2015 specifies the basic parameters, requirements, and testing methods of timing accuracy for analogue quartz clocks, hereinafter referred to as "the quartz clock". This International Standard applies to analogue quartz table and wall clocks which the oscillator frequency is 32 768 Hz and the nominal voltage is DC 1,5 V. Analogue quartz clock movements can refer to it. This International Standard does not apply to the following quartz clocks: - clocks for particular applications such as clocks used in aircraft, ship, vehicle, and facilities; - clocks incorporated into other products; - clocks in which time is radio-synchronized.
Abstract
Overview
ISO 19235:2015 - "Analogue quartz clocks - Timing accuracy" is an International Standard that defines the basic parameters, requirements, and test methods for the timing accuracy of analogue quartz table and wall clocks. It applies to quartz movements with an oscillator frequency of 32 768 Hz and a nominal supply of DC 1.5 V. The standard excludes clocks for special applications (aircraft, ships, vehicles, facilities), clocks built into other products, and radio‑synchronized clocks.
Key topics and requirements
- Mean instantaneous rate: After continuous running for 3 days, the mean instantaneous rate (average of three daily instantaneous rates) shall be within −1.0 s/d to +1.0 s/d.
- Voltage coefficient (C_U): Variation of instantaneous rate per volt; required to be within −1.0 to +1.0 s/(d·V). Measured by comparing rates at nominal DC 1.50 V and at 1.35 V (90%).
- Temperature coefficients (C_t1, C_t2): Defined for decrease (23 °C → 8 °C) and increase (23 °C → 38 °C). One coefficient must lie between 0 and +0.1 s/(d·°C) and the other between −0.1 and 0 s/(d·°C).
- Test conditions and apparatus:
- Ambient: 18–25 °C, variation ±2 °C; relative humidity 50–70%.
- Power supply: nominal DC 1.5 V.
- Pre‑running: at least 2 h in test environment.
- Apparatus resolution and permissible errors are specified (instantaneous rate instrument resolution 0.01 s/d, max error ±0.03 s/d).
- Performance over temperature and ageing:
- Instantaneous rate in 8–38 °C should be within −2.0 s/d to +1.0 s/d.
- Typical ageing effect: about ±0.2 s/d per year under normal use (informative guidance).
Applications and users
ISO 19235:2015 is practical for:
- Manufacturers of analogue quartz table and wall clocks for design verification and production quality control.
- Test laboratories and conformity assessment bodies performing timing accuracy tests.
- Product managers and spec writers preparing technical specifications or datasheets for quartz clock movements.
- Procurement and quality assurance teams requiring objective acceptance criteria for timing performance.
- Retailers and consumer information to set realistic performance expectations.
This standard supports consistent, comparable benchmarking of timing accuracy and helps reduce warranty claims and field failures related to timing drift.
Related standards
- ISO 6426-2 - Horological vocabulary (technical and commercial definitions) - referenced by ISO 19235.
- ISO/TC 114 (Horology) - technical committee responsible for related clock and watch standards.
Keywords: ISO 19235:2015, analogue quartz clocks, timing accuracy, quartz clock testing, mean instantaneous rate, voltage coefficient, temperature coefficient, horology standard.
Технические детали
- Технический комитет
- ISO/TC 114/SC 14 - Table and wall clocks
- SKU
- ISO 19235:2015
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
ISO 6426-2:2002/Amd 1:2012
ОтменёнHorological vocabulary — Part 2: Technical and commercial definitions — Amendment 1
Overview ISO 6426-2:2002/Amd 1:2012 is an amendment to the international standard ISO 6426-2, which focuses on horological vocabulary. Specifically, Part 2 of this standard covers technical and comme…
BS ISO 19235:2015
ДействующийAnalogue quartz clocks. Timing accuracy.
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…