ISO 20498-2:2017 PDF
Traditional Chinese medicine — Computerized tongue image analysis system — Part 2: Light environment
Traditional Chinese medicine — Computerized tongue image analysis system — Part 2: Light environment
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 6
- Дата публикации:
- 17 мая 2017 г.
- Издание:
- ISO IS 20498 edition 1 version 1
- ICS:
- 11.040.99
ISO 20498-2:2017 specifies the light environment necessary for the functioning of a computerized tongue image analysis system (CTIS). ISO 20498-2:2017 does not include the electrical safety and biocompatibility of the lighting component.
Abstract
Overview
ISO 20498-2:2017 specifies the light environment required for a Computerized Tongue Image Analysis System (CTIS). The standard defines optical conditions on the effective surface area where a patient’s tongue is imaged - covering illuminance, colour temperature, colour rendering, illumination uniformity, irradiance and ultraviolet (UV) irradiance. It does not cover electrical safety or biocompatibility of lighting components.
Keywords: ISO 20498-2:2017, CTIS, computerized tongue image analysis system, light environment, illuminance, colour temperature, colour rendering index, irradiance, ultraviolet irradiance.
Key topics and technical requirements
- Illuminance: 500 lx to 13 000 lx across the effective surface area.
- Colour temperature (CCT): 3 000 K to 7 000 K to control visual appearance and sensor response.
- Colour rendering index (CRI): > 90 to ensure accurate colour reproduction for diagnostic analysis.
- Illumination distribution (uniformity): ratio of minimum to maximum illuminance on the effective area must be > 0.9 (high uniformity).
- Irradiance (300–2 500 nm): total irradiance shall not exceed 350 W·m–2 (thermal/retinal/skin risk control).
- Effective UV irradiance (200–400 nm): shall not exceed 0.008 W·m–2 using the spectral weighting function in Annex A (actinic hazard assessment).
- Test methods: specifies a measuring grid (partial surfaces with centres ≤3 cm apart) and measurement procedures: illuminance meter for lux, spectroradiometer/sensor for spectral irradiance and UV, CRI measurement per CIE 013.3-1995. Sensor for irradiance measurements should have diameter ≤ 3 cm; measure at the point of maximum illuminance.
Applications and practical value
- Ensures consistent, repeatable imaging conditions for automated tongue diagnosis in Traditional Chinese Medicine (TCM) and related clinical workflows.
- Guides selection and validation of lighting systems for CTIS devices - important for manufacturers, system integrators and test labs.
- Protects patient safety by limiting thermal and photobiological exposure (irradiance and UV limits).
- Improves diagnostic reliability by enforcing high CRI and strict uniformity, reducing colour and shading artifacts that can skew image analysis algorithms.
- Useful for clinical deployment, device certification, quality assurance, and imaging protocol development.
Who should use this standard
- CTIS and medical imaging device manufacturers
- Clinical engineers, quality managers and regulatory/compliance teams
- Test laboratories and certification bodies
- Researchers developing tongue image analysis algorithms and imaging protocols
- TCM clinics adopting digital diagnostic tools
Related standards
- CIE 013.3-1995 (colour rendering measurement methods)
- IEC 62471:2006 (photobiological safety - referenced for UV weighting)
- Other parts of the ISO 20498 series (see ISO website for the full list)
Технические детали
- Технический комитет
- ISO/TC 249 - Traditional Chinese medicine
- SKU
- ISO 20498-2:2017
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
IEC 62471:2006
ДействующийPhotobiological safety of lamps and lamp systems
Overview IEC 62471:2006 – Photobiological Safety of Lamps and Lamp Systems is a globally recognized standard issued by the International Electrotechnical Commission (IEC). This standard provides comp…
ISO 20498-1:2019
ДействующийTraditional Chinese medicine — Computerized tongue image analysis system — Part 1: General requirements
Overview ISO 20498-1:2019 defines the general requirements for a Computerized Tongue Image Analysis System (CTIS) used in Traditional Chinese Medicine (TCM). The standard focuses on the technical and…
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…