ISO 21501-1:2009 PDF
Determination of particle size distribution — Single particle light interaction methods — Part 1: Light scattering aerosol spectrometer
Determination of particle size distribution — Single particle light interaction methods — Part 1: Light scattering aerosol spectrometer
- Статус документа:
- Отменён
- Формат:
- Электронный (PDF)
- Количество страниц:
- 27
- Дата публикации:
- 22 мая 2009 г.
- Издание:
- ISO IS 21501 edition 1 version 1
- ICS:
- 19.120
ISO 21501-1:2009 specifies characteristics of a light scattering aerosol spectrometer (LSAS) which is used for measuring the size, number concentration and number/size distribution of particles suspended in a gas. The light scattering technique described in this document is based upon single particle measurements. The size range of particles measured by this method is between approximately 0,06 µm to 45 µm in diameter. Instruments that conform to ISO 21501-1:2009 are used for the determination of the particle size distribution and particle number concentration at relatively high concentrations of up to 1011 particles/m3. Application fields include: characterization of metered dose inhalers (MDI), dry powder inhalers (DPI) and nebulizers in pharmacy; production control of active agents; cut-off determination: impactors, cyclones and impingers; atmospheric aerosols: bio-aerosols, stables/composting facilities, nebulized droplets, measurements in street tunnels; fractional separation efficiency determination of filters. For the above-mentioned applications, aerosol spectrometers should determine the particle size distribution, particle number concentration, size resolution and sizing accuracy as accurately as possible. These aerosol spectrometers are not suitable for the classification of clean rooms.
Abstract
Overview
ISO 21501-1:2009 defines performance and test methods for light scattering aerosol spectrometers (LSAS) used to determine particle size distribution and particle number concentration of aerosols. The standard covers single-particle light-scattering techniques for particles approximately 0.06 µm to 45 µm in diameter and provides calibration and validation procedures to improve measurement accuracy and comparability between instruments. ISO 21501-1 applies where high concentrations (up to 1×10^11 particles/m3) are measured, but it explicitly states these instruments are not suitable for clean-room classification.
Key Topics and Requirements
- Measuring size range: nominal particle diameters from ~0.06 µm to 45 µm.
- Counting efficiency: defined as the ratio of measured to actual particle concentration; lower and upper size limits are conventionally at a counting efficiency of 0.5 ± 0.15.
- Size resolution: ability to distinguish neighbouring particle sizes; limited by instrument channel widths.
- Sizing accuracy: percentage difference between certified reference particle size and instrument-indicated size (ISO provides a sizing error formula).
- Sampling flow rate: volumetric flow through the LSAS; flow error must be within ±5% (typical flows 0.5–5 L/min).
- Effective detection flow rate: volumetric flow through the optical/aerodynamic sensing zone - to be measured or calibrated.
- Maximum particle number concentration & coincidence loss: instruments must specify maximum concentration (up to 10^11 particles/m3) and ensure coincidence loss ≤ 10% at that maximum.
- Test methods: standardized procedures for size calibration, effective detection flow determination, maximum concentration testing, size resolution, and counting efficiency (see Clauses 4.1–4.5 and informative Annexes).
Applications
ISO 21501-1 is used to ensure reliable aerosol measurements in:
- Pharmaceuticals: characterization of metered-dose inhalers (MDI), dry powder inhalers (DPI), nebulizers, and production control of active agents.
- Filter and separation testing: cut-off determination for impactors, cyclones, impingers and fractional separation efficiency of filters.
- Environmental and occupational monitoring: atmospheric aerosols, bio-aerosols, nebulized droplets, stables/composting facilities and street-tunnel measurements.
- Research & development: aerosol instrument calibration and inter-comparison studies.
Who uses this standard
- Instrument manufacturers (LSAS design, calibration, and specification)
- Test laboratories and QA teams in pharmaceutical and filter industries
- Environmental and occupational hygiene professionals
- Metrology institutes performing aerosol calibration and validation
Related standards
- ISO 21501 series:
- Part 2 - Light scattering liquid-borne particle counter
- Part 3 - Light extinction liquid-borne particle counter
- Part 4 - Light scattering airborne particle counter for clean spaces
ISO 21501-1:2009 (ISO, 2009) is the reference for calibration, validation and performance requirements when using light scattering aerosol spectrometers for particle sizing and counting.
Технические детали
- Технический комитет
- ISO/TC 24/SC 4 - Particle characterization
- SKU
- ISO 21501-1:2009
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
BS ISO 21501-1:2009
ОтменёнDetermination of particle size distribution. Single particle light interaction methods - Light scattering aer…
1 Scope This part of ISO 21501 specifies characteristics of a light scattering aerosol spectrometer (LSAS) which is used for measuring the size, number concentration and number/size distribution of p…
BS ISO 21501-2:2019
ДействующийDetermination of particle size distribution. Single particle light interaction methods. Light scattering liqu…
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…