ISO 21909-1:2021 PDF
Passive neutron dosimetry systems — Part 1: Performance and test requirements for personal dosimetry
Passive neutron dosimetry systems — Part 1: Performance and test requirements for personal dosimetry
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 42
- Дата публикации:
- 3 декабря 2021 г.
- Издание:
- ISO IS 21909 edition 2 version 1
- ICS:
- 13.280
This document applies to all passive neutron detectors that can be used within a personal dosemeter in part or in all of the above-mentioned neutron energy range. No distinction between the different techniques available in the marketplace is made in the description of the tests. Only generic distinctions, for instance, as disposable or reusable dosemeters, are considered. This document describes type tests only. Type tests are made to assess the basic characteristics of the dosimetry systems and are often ensured by recognized national laboratories This document does not present performance tests for characterizing the degradation induced by the following: — intrinsic temporal variability of the quality of the dosemeter supplied by the manufacturer; — intrinsic temporal variability of preparation treatments (before irradiation and/or before reading), if existing; — intrinsic temporal variability of reading process; — degradation due to environmental effects on the preparation treatments, if existing; — degradation due to environmental effects on the reading process. This document gives information for extremity dosimetry in the Annex C, based on recommendations given by ICRU Report 66. This document addresses only neutron personal monitoring and not criticality accident conditions. The links between this document and ISO 21909-2 are given in Annex A.
Abstract
Overview
ISO 21909-1:2021 - "Passive neutron dosimetry systems - Part 1: Performance and test requirements for personal dosimetry" - defines type-test requirements for passive neutron detectors used in personal dosemeters. The standard applies to all passive neutron detector technologies (no technique-specific tests), covering detector performance across the neutron energy range used for personal monitoring. It specifies laboratory test conditions and performance checks used by recognized national laboratories to assess basic characteristics of dosimetry systems. This part addresses routine personal neutron monitoring only (not criticality accidents) and includes guidance for extremity dosimetry in Annex C. Links to Part 2 are provided in Annex A.
Key technical topics and requirements
ISO 21909-1 sets out a comprehensive set of type tests and performance requirements, including:
- General test conditions and reference radiation - standardized irradiation and environmental test conditions for reproducible evaluation.
- Intrinsic performance tests - irradiations, coefficient of variation (precision), linearity of response, energy and angle dependence, and specific checks for thermal neutrons.
- Stability and robustness tests - fading, ageing, storage effects, exposure to non-neutron radiation (photons, radon), climatic conditions, light sensitivity, drop tests, sealing and distance-to-phantom effects.
- Identification and documentation - marking and accompanying documentation requirements for dosemeters.
- Type-test scope - the document describes type tests only; it does not specify tests for performance degradation arising from intrinsic temporal variability in manufacturing, preparation, or reading processes, nor environmental degradation of those processes.
- Notable 2021 updates include adjustments to irradiation energy ranges (fast range extended to 10–19 MeV), modified mixed-field provisions, revised criteria for coefficient of variation and linearity, and updated energy/angle response limits (trumpet curves).
Practical applications and who uses it
ISO 21909-1 is used by:
- Dosimeter manufacturers - to design and validate passive neutron personal dosemeters against internationally accepted type-test criteria.
- National calibration and testing laboratories - for independent type testing and conformity assessment.
- Radiation protection professionals and health physics groups - to select suitable personal neutron monitoring devices and interpret type-test reports.
- Regulators and accreditation bodies - to define acceptance criteria for approved dosimetry systems.
- Employers of neutron-exposed workers - for procurement specifications and supplier evaluation.
Practical benefits include improved comparability of personal neutron dosimetry products, clearer procurement specifications, and standardized test evidence for regulatory compliance.
Related standards
- ISO 21909-2 - referenced in Annex A; Part 2 complements Part 1 (see the standard for links and the flow chart describing interactions).
- Other radiological protection standards and ICRU recommendations (Annex C references ICRU Report 66 for extremity dosimetry).
Технические детали
- Технический комитет
- ISO/TC 85/SC 2 - Radiological protection
- SKU
- ISO 21909-1:2021
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
SIST EN ISO 21909-1:2023
ДействующийPassive neutron dosimetry systems - Part 1: Performance and test requirements for personal dosimetry (ISO 219…
Overview EN ISO 21909-1:2023 (adoption of ISO 21909-1:2021 by CEN) specifies performance and test requirements for passive neutron dosimetry systems used in personal dosimetry. The standard applies t…
SIST EN ISO 21909-2:2023
ДействующийPassive neutron dosimetry systems - Part 2: Methodology and criteria for the qualification of personal dosime…
Overview EN ISO 21909-2:2023 (identical to ISO 21909-2:2021, adopted by CEN) defines the methodology and criteria to qualify passive neutron personal dosimetry systems at workplaces. It is intended f…
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…